Abstract

The accuracy of optical tracking systems is important to scientists. With the improvements reported in this regard, such systems have been applied to an increasing number of operations. To enhance the accuracy of these systems further and to reduce the effect of synchronization and visual field errors, this study introduces a field-programmable gate array (FPGA)-based synchronization control method, a method for measuring synchronous errors, and an error distribution map in field of view. Synchronization control maximizes the parallel processing capability of FPGA, and synchronous error measurement can effectively detect the errors caused by synchronization in an optical tracking system. The distribution of positioning errors can be detected in field of view through the aforementioned error distribution map. Therefore, doctors can perform surgeries in areas with few positioning errors, and the accuracy of optical tracking systems is considerably improved. The system is analyzed and validated in this study through experiments that involve the proposed methods, which can eliminate positioning errors attributed to asynchronous cameras and different fields of view.
Literature
1.
go back to reference García-Vázquez, V., Marinetto, E., Santos-Miranda, J. A., Calvo, F. A., Desco, M., and Pascau, J., Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios. Phys. Med. Biol. 58(24):8769–8782, 2013.PubMedCrossRef García-Vázquez, V., Marinetto, E., Santos-Miranda, J. A., Calvo, F. A., Desco, M., and Pascau, J., Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios. Phys. Med. Biol. 58(24):8769–8782, 2013.PubMedCrossRef
2.
go back to reference Lü, Y., Li, C., Liu, M., Fritz, J., Carrino, J. A., Wu, L., and Zhao, B., MRI-guided stereotactic aspiration of brain abscesses by use of an optical tracking navigation system. Acta Radiol. 55(1):121–128, 2014.PubMedCrossRef Lü, Y., Li, C., Liu, M., Fritz, J., Carrino, J. A., Wu, L., and Zhao, B., MRI-guided stereotactic aspiration of brain abscesses by use of an optical tracking navigation system. Acta Radiol. 55(1):121–128, 2014.PubMedCrossRef
3.
go back to reference Cheng, T. Y., and Herman, C., Motion tracking in infrared imaging for quantitative medical diagnostic applications. Infrared Phys. Technol. 62:70–80, 2014.PubMedPubMedCentralCrossRef Cheng, T. Y., and Herman, C., Motion tracking in infrared imaging for quantitative medical diagnostic applications. Infrared Phys. Technol. 62:70–80, 2014.PubMedPubMedCentralCrossRef
4.
go back to reference Vaccarella, A., De Momi, E., Enquobahrie, A., and Ferrigno, G., Unscented Kalman filter based sensor fusion for robust optical and electromagnetic tracking in surgical navigation. IEEE Trans. Instrum. Meas. 62(7):2067–2081, 2013.CrossRef Vaccarella, A., De Momi, E., Enquobahrie, A., and Ferrigno, G., Unscented Kalman filter based sensor fusion for robust optical and electromagnetic tracking in surgical navigation. IEEE Trans. Instrum. Meas. 62(7):2067–2081, 2013.CrossRef
5.
go back to reference Yang, R., Wang, Z., Liu, S., and Wu, X., Design of an accurate near infrared optical tracking system in surgical navigation. J. Lightwave Technol. 31(2):223–231, 2013.CrossRef Yang, R., Wang, Z., Liu, S., and Wu, X., Design of an accurate near infrared optical tracking system in surgical navigation. J. Lightwave Technol. 31(2):223–231, 2013.CrossRef
6.
go back to reference Cheng, P., Jhiang, S. M., and Menq, C. H., Real-time visual sensing system achieving high-speed 3D particle tracking with nanometer resolution. Appl. Opt. 52(31):7530–7539, 2013.PubMedCrossRef Cheng, P., Jhiang, S. M., and Menq, C. H., Real-time visual sensing system achieving high-speed 3D particle tracking with nanometer resolution. Appl. Opt. 52(31):7530–7539, 2013.PubMedCrossRef
7.
go back to reference Ohtani, K., and Baba, M., A high-speed, high-accuracy optical position sensor integrated with an analog and digital signal-processing circuit. Electron. Commun. Jpn. 94(12):12–21, 2011.CrossRef Ohtani, K., and Baba, M., A high-speed, high-accuracy optical position sensor integrated with an analog and digital signal-processing circuit. Electron. Commun. Jpn. 94(12):12–21, 2011.CrossRef
8.
go back to reference Schuppe, O., An optical tracking system for a microsurgical training simulator. Stud. Health Technol. Inform. 173:445–449, 2012.PubMed Schuppe, O., An optical tracking system for a microsurgical training simulator. Stud. Health Technol. Inform. 173:445–449, 2012.PubMed
9.
go back to reference Blostein, S. D., and Huang, T. S., Error analysis in stereo determination of 3-D point positions. IEEE Trans. Pattern Anal. Mach. Intell. 9(6):752–765, 1987.PubMedCrossRef Blostein, S. D., and Huang, T. S., Error analysis in stereo determination of 3-D point positions. IEEE Trans. Pattern Anal. Mach. Intell. 9(6):752–765, 1987.PubMedCrossRef
10.
go back to reference Olague, G., and Mohr, R., Optimal camera placement for accurate reconstruction. Pattern Recogn. 35(4):927–944, 2002.CrossRef Olague, G., and Mohr, R., Optimal camera placement for accurate reconstruction. Pattern Recogn. 35(4):927–944, 2002.CrossRef
11.
go back to reference Helm, P. A., Teichman, R., Hartmann, S. L., and Simon, D., Spinal navigation and imaging: history, trends, and future. IEEE Trans. Med. Imaging 34(8):1738–1746, 2015.PubMedCrossRef Helm, P. A., Teichman, R., Hartmann, S. L., and Simon, D., Spinal navigation and imaging: history, trends, and future. IEEE Trans. Med. Imaging 34(8):1738–1746, 2015.PubMedCrossRef
12.
go back to reference Wiles, A. D., Thompson, D. G., and Frantz, D. D., Accuracy assessment and interpretation for optical tracking systems. Proc. SPIE Int. Soc. Opt. Eng. 5367:421–432, 2004. Wiles, A. D., Thompson, D. G., and Frantz, D. D., Accuracy assessment and interpretation for optical tracking systems. Proc. SPIE Int. Soc. Opt. Eng. 5367:421–432, 2004.
13.
go back to reference Yang, R., Cheng, S., and Chen, Y., Flexible and accurate implementation of a binocular structured light system. Opt. Lasers Eng. 46(5):373–379, 2008.CrossRef Yang, R., Cheng, S., and Chen, Y., Flexible and accurate implementation of a binocular structured light system. Opt. Lasers Eng. 46(5):373–379, 2008.CrossRef
Metadata
Title
Synchronization Design and Error Analysis of Near-Infrared Cameras in Surgical Navigation
Authors
Ken Cai
Rongqian Yang
Huazhou Chen
Yizhou Huang
Xiaoyan Wen
Wenhua Huang
Shanxing Ou
Publication date
01-01-2016
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 1/2016
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-015-0368-2

Other articles of this Issue 1/2016

Journal of Medical Systems 1/2016 Go to the issue