Abstract

As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further migration of the device into other chambers of heart which leads to difficulty in finding and retrieval of the device. The authors propose a simple and unique technique to prevent further migration of the septal occluder device.
Appendix
Available only for authorised users
Literature
1.
go back to reference King TD, Thompson SL, Steiner C, Mills NL: Secundum atrial septal defects: nonoperative closure during cardiac catheterization. JAMA. 1976, 235: 2506-2509. 10.1001/jama.1976.03260490024013.CrossRefPubMed King TD, Thompson SL, Steiner C, Mills NL: Secundum atrial septal defects: nonoperative closure during cardiac catheterization. JAMA. 1976, 235: 2506-2509. 10.1001/jama.1976.03260490024013.CrossRefPubMed
2.
go back to reference Post MC, Suttorp MJ, Jaarsma W: Comparison of outcome and complications using different types of devices for percutaneous closure of a secundum atrial septal defect in adults:a single center experience. Catheter Cardiovasc Interv. 2006, 67: 438-443. 10.1002/ccd.20625.CrossRefPubMed Post MC, Suttorp MJ, Jaarsma W: Comparison of outcome and complications using different types of devices for percutaneous closure of a secundum atrial septal defect in adults:a single center experience. Catheter Cardiovasc Interv. 2006, 67: 438-443. 10.1002/ccd.20625.CrossRefPubMed
3.
go back to reference Butera G, Carminati M, Chessa M: Percutaneous versus surgical closure of secundum atrial septal defect: comparison of early results and complications. Am Heart J. 2006, 151: 228-234. 10.1016/j.ahj.2005.02.051.CrossRefPubMed Butera G, Carminati M, Chessa M: Percutaneous versus surgical closure of secundum atrial septal defect: comparison of early results and complications. Am Heart J. 2006, 151: 228-234. 10.1016/j.ahj.2005.02.051.CrossRefPubMed
4.
go back to reference Thanopoulos BD, Laskari CV, Tsaousis GS: Closure of atrial septal defects with the Amplatzer occlusion device: preliminary results. J Am Coll Cardiol. 1998, 31: 1110-1116. 10.1016/S0735-1097(98)00039-4.CrossRefPubMed Thanopoulos BD, Laskari CV, Tsaousis GS: Closure of atrial septal defects with the Amplatzer occlusion device: preliminary results. J Am Coll Cardiol. 1998, 31: 1110-1116. 10.1016/S0735-1097(98)00039-4.CrossRefPubMed
5.
go back to reference Chessa M, Carminati M, Bufera G, Bini RM, Drago M, Rosti L, Giamberti A, Pome G, Bossone E, Frigiola A: Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol. 2002, 39: 1061-1065. 10.1016/S0735-1097(02)01711-4.CrossRefPubMed Chessa M, Carminati M, Bufera G, Bini RM, Drago M, Rosti L, Giamberti A, Pome G, Bossone E, Frigiola A: Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol. 2002, 39: 1061-1065. 10.1016/S0735-1097(02)01711-4.CrossRefPubMed
6.
go back to reference Berger F, Vogel M, Alexi-Meskishvili V: Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. J Thorac Cardiovasc Surg. 1999, 118: 674-680. 10.1016/S0022-5223(99)70013-9.CrossRefPubMed Berger F, Vogel M, Alexi-Meskishvili V: Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. J Thorac Cardiovasc Surg. 1999, 118: 674-680. 10.1016/S0022-5223(99)70013-9.CrossRefPubMed
7.
go back to reference Agarwal SK, Ghosh P, Mittal P: Failure of devices used for closure of atrial septal defects: mechanisms and management. J Thorac Cardiovasc Surg. 1996, 112: 21-26. 10.1016/S0022-5223(96)70173-3.CrossRefPubMed Agarwal SK, Ghosh P, Mittal P: Failure of devices used for closure of atrial septal defects: mechanisms and management. J Thorac Cardiovasc Surg. 1996, 112: 21-26. 10.1016/S0022-5223(96)70173-3.CrossRefPubMed
8.
go back to reference Balbi M, Pongiglione G, Bezante GP: Catheter Cardiovasc Interv. Percutaneous rescue of left ventricular embolized amplatzer septal occluder device. 2008, 72 (4): 559-562. Balbi M, Pongiglione G, Bezante GP: Catheter Cardiovasc Interv. Percutaneous rescue of left ventricular embolized amplatzer septal occluder device. 2008, 72 (4): 559-562.
9.
go back to reference Berdat PA, Chatterjee T, Pfammatter JP, Windecker S, Meier B, Carrel T: Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale. J Thorac Cardiovasc Surg. 2000, 120: 1034-1039. 10.1067/mtc.2000.111054.CrossRefPubMed Berdat PA, Chatterjee T, Pfammatter JP, Windecker S, Meier B, Carrel T: Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale. J Thorac Cardiovasc Surg. 2000, 120: 1034-1039. 10.1067/mtc.2000.111054.CrossRefPubMed
Metadata
Title
Suture fixation of migrated septal occluder device to prevent further migration: a simple surgical technique
Authors
Prashant N Mohite
Sachin A Kuthe
Shrirang D Ranade
Pravin P Kulkarni
Anton Sabashnikov
Aron F Popov
Publication date
01-12-2013
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2013
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/1749-8090-8-10

Other articles of this Issue 1/2013

Journal of Cardiothoracic Surgery 1/2013 Go to the issue