Skip to main content
Top
Published in: Nuclear Medicine and Molecular Imaging 3/2018

01-06-2018 | Original Article

Survey Result of the Counting Efficiency of Gamma Counter by Certified Reference Materials

Authors: Ji-In Bang, Ho-Young Lee, Geyoung Woon Noh, Jeong Mi Park, June Kee Yoon

Published in: Nuclear Medicine and Molecular Imaging | Issue 3/2018

Login to get access

Abstract

Purpose

In radioimmunoassay (RIA), the gamma counter is the important instrument for the accurate measurement. To manage quality assurance of RIA, the counting efficiency of gamma counter is one of the important parameters. The aim of this study was to evaluate the counting efficiency of gamma counters in multiple institutes on the base of traceability by using the certified reference materials (CRMs).

Methods

Twenty-three institutes that perform RIA were enrolled in this study. I-125 CRMs that were certified by National Institute of Standards and Technology (NIST) were used. Each institute was asked to count the activity of I-125 CRMs at most twice on all gamma counters in use. The counting efficiency of each well of counter was calculated on the base of NIST-certified information, corrected for I-125 decay for date of testing.

Results

From 23 institutes, 44 gamma counters were evaluated. The average counting efficiency of all wells was 85.9% and the standard deviation was 13.5%. As a mean value of each gamma counter, three gamma counters showed poor counting efficiency (less than 70%). The poorest counting efficiency was 7%. The counting efficiency of seven gamma counters was between 70 and 75%. Eight counters had the counting efficiency between 75 and 90%. More than half of counter (26 gamma counters) showed excellent counting efficiency (more than 90%). The standard deviation variation range of inter-well efficiency was from 0 to 11.2.

Conclusion

The first survey on the counting efficiency of gamma counter was performed in South Korea. Most of the RIA laboratories have well managed the quality assurance of gamma counter.
Literature
2.
go back to reference Zaidi P, Kamal S. Radioimmunoassay: principle and technique. J Pak Med Assoc. 1993;43:264.PubMed Zaidi P, Kamal S. Radioimmunoassay: principle and technique. J Pak Med Assoc. 1993;43:264.PubMed
3.
go back to reference Lee JM, Lee HH, Park S, Kim TS, Kim S-K. Random assay in radioimmunoassay: feasibility and application compared with batch assay. Nucl Med Mol Imaging. 2016;50:337–43.CrossRefPubMedPubMedCentral Lee JM, Lee HH, Park S, Kim TS, Kim S-K. Random assay in radioimmunoassay: feasibility and application compared with batch assay. Nucl Med Mol Imaging. 2016;50:337–43.CrossRefPubMedPubMedCentral
4.
go back to reference Lodge MA, Holt DP, Kinahan PE, Wong DF, Wahl RL. Performance assessment of a NaI (Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization. EJNMMI physics. 2015;2:11.CrossRefPubMedPubMedCentral Lodge MA, Holt DP, Kinahan PE, Wong DF, Wahl RL. Performance assessment of a NaI (Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization. EJNMMI physics. 2015;2:11.CrossRefPubMedPubMedCentral
5.
go back to reference ISO I. 15189: 2012 Medical laboratories–requirements for quality and competence. Geneva: International Standardisation Organisation. 2012. ISO I. 15189: 2012 Medical laboratories–requirements for quality and competence. Geneva: International Standardisation Organisation. 2012.
6.
go back to reference AD MN, Wilkinson A. Compendium of chemical terminology: IUPAC. Oxford: Blackwell Science; 1997. AD MN, Wilkinson A. Compendium of chemical terminology: IUPAC. Oxford: Blackwell Science; 1997.
7.
go back to reference Bales ZB, Patterson JF, Hoofnagle JH, Seeff LB. Variation in gamma counter efficiency used in radioimmunoassay testing for hepatitis B surface antigen and antibody. Transfusion. 1978;18:91–3.CrossRefPubMed Bales ZB, Patterson JF, Hoofnagle JH, Seeff LB. Variation in gamma counter efficiency used in radioimmunoassay testing for hepatitis B surface antigen and antibody. Transfusion. 1978;18:91–3.CrossRefPubMed
8.
go back to reference Chambron J. Quantitative analysis in imaging and function. Chambron J. Quantitative analysis in imaging and function.
9.
go back to reference De Bièvre P, Günzler H. Traceability in chemical measurement. Springer; 2005. De Bièvre P, Günzler H. Traceability in chemical measurement. Springer; 2005.
Metadata
Title
Survey Result of the Counting Efficiency of Gamma Counter by Certified Reference Materials
Authors
Ji-In Bang
Ho-Young Lee
Geyoung Woon Noh
Jeong Mi Park
June Kee Yoon
Publication date
01-06-2018
Publisher
Springer Berlin Heidelberg
Published in
Nuclear Medicine and Molecular Imaging / Issue 3/2018
Print ISSN: 1869-3474
Electronic ISSN: 1869-3482
DOI
https://doi.org/10.1007/s13139-018-0515-z

Other articles of this Issue 3/2018

Nuclear Medicine and Molecular Imaging 3/2018 Go to the issue