Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 2/2012

01-02-2012 | Symposium: Papers Presented at the Annual Meetings of The Hip Society

Surgical Technique: Transfer of the Anterior Portion of the Gluteus Maximus Muscle for Abductor Deficiency of the Hip

Author: Leo A. Whiteside, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 2/2012

Login to get access

Abstract

Background

Loss of the abductor portions of the gluteus medius and gluteus minimus muscles due to THA causes severe limp and often instability.

Description of Technique

To minimize the symptoms of limp and instability, the anterior ½ of the gluteus maximus was transferred to the greater trochanter and sutured under the vastus lateralis. A separate posterior flap was transferred under the primary flap to substitute for the gluteus minimus and capsule. To ensure tight repair, the flaps were attached and tensioned in abduction.

Patients and Methods

The technique was performed in 11 patients (11 hips) with complete loss of abductor attachment; the procedure was performed in nine patients during THA and in two later as a secondary procedure. Preoperatively, all patients had abductor lurch, positive Trendelenburg sign, and no abduction of the hip against gravity. Minimum followup was 16 months (mean, 33 months; range, 16–42 months).

Results

Postoperatively, nine patients had strong abduction of the hip against gravity, no abductor lurch, and negative Trendelenburg sign. One patient had weak abduction against gravity, negative Trendelenburg sign, and slight abductor lurch. One patient failed to achieve strong abduction, had severe limp after 6 months of protection and physical therapy, and was lost to followup.

Conclusions

Gluteus maximus transfer can restore abductor function in THA with a high success rate.
Literature
1.
go back to reference Alberton GM, High WA, Morrey BF. Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am. 2002;84:1788–1792.PubMed Alberton GM, High WA, Morrey BF. Dislocation after revision total hip arthroplasty: an analysis of risk factors and treatment options. J Bone Joint Surg Am. 2002;84:1788–1792.PubMed
2.
go back to reference Arkoulakis NS, Angel CL, DuBeshter B, Serletti JM. Reconstruction of an extensive vulvectomy defect using the gluteus maximus fasciocutaneous V-Y advancement flap. Ann Plast Surg. 2002;49:50–54.PubMedCrossRef Arkoulakis NS, Angel CL, DuBeshter B, Serletti JM. Reconstruction of an extensive vulvectomy defect using the gluteus maximus fasciocutaneous V-Y advancement flap. Ann Plast Surg. 2002;49:50–54.PubMedCrossRef
3.
go back to reference Busfield BT, Huffman GR, Nahai F, Hoffman W, Ries MD. Extended medial gastrocnemius rotational flap for treatment of chronic knee extensor mechanisms deficiency in patients with and without total knee arthroplasty. Clin Orthop Relat Res. 2004;428:190–197.PubMedCrossRef Busfield BT, Huffman GR, Nahai F, Hoffman W, Ries MD. Extended medial gastrocnemius rotational flap for treatment of chronic knee extensor mechanisms deficiency in patients with and without total knee arthroplasty. Clin Orthop Relat Res. 2004;428:190–197.PubMedCrossRef
4.
go back to reference Carr AM, DeSteiger R. Osteolysis in patients with a metal-on-metal arthroplasty. ANZ J Surg. 2008;78:144–147.PubMedCrossRef Carr AM, DeSteiger R. Osteolysis in patients with a metal-on-metal arthroplasty. ANZ J Surg. 2008;78:144–147.PubMedCrossRef
5.
go back to reference Coventry MB. Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am. 1985;67:832–841.PubMed Coventry MB. Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am. 1985;67:832–841.PubMed
6.
go back to reference Evans EM, Freeman MA, Miller AJ, Vernon-Roberts B. Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg Br. 1974;56:626–642.PubMed Evans EM, Freeman MA, Miller AJ, Vernon-Roberts B. Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg Br. 1974;56:626–642.PubMed
7.
go back to reference Gray H. Gray’s Anatomy. 1901 ed. Philadelphia, PA: Running Press; 1974. Gray H. Gray’s Anatomy. 1901 ed. Philadelphia, PA: Running Press; 1974.
8.
go back to reference Josvay J, Sashegyi M, Kelemen P, Donath A. Clinical experience with the hatchet-shaped gluteus maximus musculocutaneous flap. Ann Plast Surg. 2005;55:179–182.PubMedCrossRef Josvay J, Sashegyi M, Kelemen P, Donath A. Clinical experience with the hatchet-shaped gluteus maximus musculocutaneous flap. Ann Plast Surg. 2005;55:179–182.PubMedCrossRef
9.
go back to reference Killampalli VV, Reading AD. Late instability of bilateral metal on metal hip resurfacings due to progressive local tissue effects. Hip Int. 2009;19:287–291.PubMed Killampalli VV, Reading AD. Late instability of bilateral metal on metal hip resurfacings due to progressive local tissue effects. Hip Int. 2009;19:287–291.PubMed
10.
go back to reference Koh PK, Tan BK, Hong SW, Tan MH, Tay AG, Song C, Tan KC. The gluteus maximus muscle flap for reconstruction of sacral chordoma defects. Ann Plast Surg. 2004;53:44–49.PubMedCrossRef Koh PK, Tan BK, Hong SW, Tan MH, Tay AG, Song C, Tan KC. The gluteus maximus muscle flap for reconstruction of sacral chordoma defects. Ann Plast Surg. 2004;53:44–49.PubMedCrossRef
11.
go back to reference Park YS, Moon YW, Lim SJ, Yang JM, Ahh G, Choi YL. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005;87:1515–1521.PubMedCrossRef Park YS, Moon YW, Lim SJ, Yang JM, Ahh G, Choi YL. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005;87:1515–1521.PubMedCrossRef
12.
go back to reference Spahn G, Kirschbaum S, Klinger HM. A study for evaluating the effect of the deltoid-flap repair in massive rotator cuff defects. Knee Surg Sports Traumatol Arthrosc. 2006;14:365–372.PubMedCrossRef Spahn G, Kirschbaum S, Klinger HM. A study for evaluating the effect of the deltoid-flap repair in massive rotator cuff defects. Knee Surg Sports Traumatol Arthrosc. 2006;14:365–372.PubMedCrossRef
13.
go back to reference Whiteside LA. Major femoral bone loss in revision total hip arthroplasty treated with tapered, porous-coated stems. Clin Orthop Relat Res. 2004;429:222–226.PubMedCrossRef Whiteside LA. Major femoral bone loss in revision total hip arthroplasty treated with tapered, porous-coated stems. Clin Orthop Relat Res. 2004;429:222–226.PubMedCrossRef
14.
go back to reference Whiteside LA, Nayfeh TA, Katerberg BJ. Gluteus maximus flap transfer for greater trochanter reconstruction in revision THA. Clin Orthop Relat Res. 2006;453:203–210.PubMedCrossRef Whiteside LA, Nayfeh TA, Katerberg BJ. Gluteus maximus flap transfer for greater trochanter reconstruction in revision THA. Clin Orthop Relat Res. 2006;453:203–210.PubMedCrossRef
Metadata
Title
Surgical Technique: Transfer of the Anterior Portion of the Gluteus Maximus Muscle for Abductor Deficiency of the Hip
Author
Leo A. Whiteside, MD
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-1975-y

Other articles of this Issue 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Go to the issue

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Papers Presented at the Annual Meetings of the Hip Society 2011: Editorial Comment

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Tantalum Augments for Paprosky IIIA Defects Remain Stable at Midterm Followup