Skip to main content
Top
Published in: Neuroradiology 12/2020

Open Access 01-12-2020 | Stroke | Interventional Neuroradiology

Radiation exposure in endovascular stroke treatment of acute basilar artery occlusions—a matched-pair analysis

Authors: Charlotte S. Weyland, Arne Potreck, Ulf Neuberger, Markus A. Möhlenbruch, Simon Nagel, Peter A. Ringleb, Martin Bendszus, Johannes A. R. Pfaff

Published in: Neuroradiology | Issue 12/2020

Login to get access

Abstract

Purpose

To determine the radiation exposure in endovascular stroke treatment (EST) of acute basilar artery occlusions (BAO) and compare it with radiation exposure of EST for embolic middle cerebral artery occlusions (MCAO).

Methods

In this retrospective analysis of an institutional review board−approved prospective stroke database of a comprehensive stroke center, we focused on radiation exposure (as per dose area product in Gy × cm2, median (IQR)), procedure time, and fluoroscopy time (in minutes, median [IQR]) in patients receiving EST for BAO. Patients who received EST for BAO were matched case by case with patients who received EST for MCAO according to number of thrombectomy attempts, target vessel reperfusion result, and thrombectomy technique.

Results

Overall 180 patients (n = 90 in each group) were included in this analysis. General anesthesia was conducted more often during EST of BAO (BAO: 75 (83.3%); MCAO: 18 (31.1%), p < 0.001). Procedure time (BAO: 31 (20–43); MCAO: 27 (18–38); p value 0.226) and fluoroscopy time (BAO: 29 (20–59); MCAO: 29 (17–49), p value 0.317) were comparable. Radiation exposure was significantly higher in patients receiving EST for BAO (BAO: 123.4 (78.7–204.2); MCAO: 94.3 (65.5–163.7), p value 0.046), which represents an increase by 23.7%.

Conclusion

Endovascular stroke treatment of basilar artery occlusions is associated with a higher radiation exposure compared with treatment of middle cerebral artery occlusions.
Literature
2.
3.
go back to reference Shams T, Zaidat O, Yavagal D, Xavier A, Jovin T, Janardhan V (2016) Society of Vascular and Interventional Neurology (SVIN) stroke interventional laboratory consensus (SILC) criteria: a 7M management approach to developing a stroke interventional laboratory in the era of stroke thrombectomy for large vessel occlusions. Interv Neurol 5(1–2):1–28. https://doi.org/10.1159/000443617CrossRefPubMedPubMedCentral Shams T, Zaidat O, Yavagal D, Xavier A, Jovin T, Janardhan V (2016) Society of Vascular and Interventional Neurology (SVIN) stroke interventional laboratory consensus (SILC) criteria: a 7M management approach to developing a stroke interventional laboratory in the era of stroke thrombectomy for large vessel occlusions. Interv Neurol 5(1–2):1–28. https://​doi.​org/​10.​1159/​000443617CrossRefPubMedPubMedCentral
4.
go back to reference Vano E, Jarvinen H, Kosunen A, Bly R, Malone J, Dowling A, Larkin A, Padovani R, Bosmans H, Dragusin O, Jaschke W, Torbica P, Back C, Schreiner A, Bokou C, Kottou S, Tsapaki V, Jankowski J, Papierz S, Domienik J, Werduch A, Nikodemova D, Salat D, Kepler K, Bor MD, Vassileva J, Borisova R, Pellet S, Corbett RH (2008) Patient dose in interventional radiology: a European survey. Radiat Prot Dosim 129(1–3):39–45. https://doi.org/10.1093/rpd/ncn024CrossRef Vano E, Jarvinen H, Kosunen A, Bly R, Malone J, Dowling A, Larkin A, Padovani R, Bosmans H, Dragusin O, Jaschke W, Torbica P, Back C, Schreiner A, Bokou C, Kottou S, Tsapaki V, Jankowski J, Papierz S, Domienik J, Werduch A, Nikodemova D, Salat D, Kepler K, Bor MD, Vassileva J, Borisova R, Pellet S, Corbett RH (2008) Patient dose in interventional radiology: a European survey. Radiat Prot Dosim 129(1–3):39–45. https://​doi.​org/​10.​1093/​rpd/​ncn024CrossRef
6.
go back to reference Bergeron P, Carrier R, Roy D, Blais N, Raymond J (1994) Radiation doses to patients in neurointerventional procedures. AJNR Am J Neuroradiol 15(10):1809–1812PubMed Bergeron P, Carrier R, Roy D, Blais N, Raymond J (1994) Radiation doses to patients in neurointerventional procedures. AJNR Am J Neuroradiol 15(10):1809–1812PubMed
9.
go back to reference Weyland CS, Hemmerich F, Möhlenbruch MA, Bendszus M, Pfaff JAR. Radiation exposure and fluoroscopy time in mechanical thrombectomy of anterior circulation ischemic stroke depending on the interventionalist's experience-a retrospective single center experience. Eur Radiol. 2020 Mar;30(3):1564–1570. https://doi.org/10.1007/s00330-019-06482-4 Weyland CS, Hemmerich F, Möhlenbruch MA, Bendszus M, Pfaff JAR. Radiation exposure and fluoroscopy time in mechanical thrombectomy of anterior circulation ischemic stroke depending on the interventionalist's experience-a retrospective single center experience. Eur Radiol. 2020 Mar;30(3):1564–1570. https://​doi.​org/​10.​1007/​s00330-019-06482-4
10.
go back to reference Guenego A, Mosimann PJ, Pereira VM, Nicholson P, Zuber K, Lotterie JA, Dobrocky T, Marcellus DG, Olivot JM, Piotin M, Gralla J, Fahed R, Wintermark M, Heit JJ, Cognard C (2019) Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients. Eur Radiol 29(7):3506–3515. https://doi.org/10.1007/s00330-019-06062-6CrossRefPubMed Guenego A, Mosimann PJ, Pereira VM, Nicholson P, Zuber K, Lotterie JA, Dobrocky T, Marcellus DG, Olivot JM, Piotin M, Gralla J, Fahed R, Wintermark M, Heit JJ, Cognard C (2019) Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients. Eur Radiol 29(7):3506–3515. https://​doi.​org/​10.​1007/​s00330-019-06062-6CrossRefPubMed
11.
12.
go back to reference Deutsches Institut für Normung eV (2014) Image quality assurance in diagnostic X-ray departments - Part 157: X-ray ordinance acceptance and constancy test of image display systems in their environment. https://doi.org/10.31030/2233871 Deutsches Institut für Normung eV (2014) Image quality assurance in diagnostic X-ray departments - Part 157: X-ray ordinance acceptance and constancy test of image display systems in their environment. https://​doi.​org/​10.​31030/​2233871
14.
go back to reference Weyland CS, Neuberger U, Seker F, Nagel S, Arthur Ringleb P, Mohlenbruch MA, Bendszus M, Pfaff JA (2020) Effect of treatment technique on radiation exposure in mechanical thrombectomy for acute ischaemic stroke: a matched-pair analysis. Neuroradiol J:1971400920925433. https://doi.org/10.1177/1971400920925433 Weyland CS, Neuberger U, Seker F, Nagel S, Arthur Ringleb P, Mohlenbruch MA, Bendszus M, Pfaff JA (2020) Effect of treatment technique on radiation exposure in mechanical thrombectomy for acute ischaemic stroke: a matched-pair analysis. Neuroradiol J:1971400920925433. https://​doi.​org/​10.​1177/​1971400920925433​
Metadata
Title
Radiation exposure in endovascular stroke treatment of acute basilar artery occlusions—a matched-pair analysis
Authors
Charlotte S. Weyland
Arne Potreck
Ulf Neuberger
Markus A. Möhlenbruch
Simon Nagel
Peter A. Ringleb
Martin Bendszus
Johannes A. R. Pfaff
Publication date
01-12-2020
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 12/2020
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-020-02490-0

Other articles of this Issue 12/2020

Neuroradiology 12/2020 Go to the issue