Skip to main content
Top
Literature
1.
go back to reference Brandmeir NJ, Savaliya S, Rohatgi P, Sather M (2017) The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques. J Robot Surg. doi:10.1007/s11701-017-0712-2 Brandmeir NJ, Savaliya S, Rohatgi P, Sather M (2017) The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques. J Robot Surg. doi:10.​1007/​s11701-017-0712-2
2.
go back to reference Mullin JP, Shriver M, Alomar S, Najm I, Bulacio J, Chauvel P, Gonzalez-Martinez J (2016) Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia 57:386–401CrossRefPubMed Mullin JP, Shriver M, Alomar S, Najm I, Bulacio J, Chauvel P, Gonzalez-Martinez J (2016) Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia 57:386–401CrossRefPubMed
3.
go back to reference Cardinale F, Casaceli G, Raneri F, Miller JP, Lo Russo G (2016) Implantation of StereoElectroEncephaloGraphy (SEEG) electrodes: a systematic review. J Clin Neurophysiol 33:490–502CrossRefPubMed Cardinale F, Casaceli G, Raneri F, Miller JP, Lo Russo G (2016) Implantation of StereoElectroEncephaloGraphy (SEEG) electrodes: a systematic review. J Clin Neurophysiol 33:490–502CrossRefPubMed
4.
go back to reference Vakharia VN, Sparks R, O’Keeffe AG, Rodionov R, Miserocchi A, McEvoy A, Ourselin S, Duncan J (2017) Accuracy of intracranial electrode placement for stereoencephalography: a systematic review and meta-analysis. Epilepsia. doi:10.1111/epi.13713 PubMed Vakharia VN, Sparks R, O’Keeffe AG, Rodionov R, Miserocchi A, McEvoy A, Ourselin S, Duncan J (2017) Accuracy of intracranial electrode placement for stereoencephalography: a systematic review and meta-analysis. Epilepsia. doi:10.​1111/​epi.​13713 PubMed
5.
go back to reference Cardinale F, Cossu M, Castana L, Casaceli G, Schiariti MP, Miserocchi A, Fuschillo D, Moscato A, Caborni C, Arnulfo G, Lo Russo G (2013) Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 72:353–366CrossRefPubMed Cardinale F, Cossu M, Castana L, Casaceli G, Schiariti MP, Miserocchi A, Fuschillo D, Moscato A, Caborni C, Arnulfo G, Lo Russo G (2013) Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 72:353–366CrossRefPubMed
6.
go back to reference Cardinale F (2016) Stereoelectroencephalography: application accuracy, efficacy, and safety. World Neurosurg 94:570–571CrossRefPubMed Cardinale F (2016) Stereoelectroencephalography: application accuracy, efficacy, and safety. World Neurosurg 94:570–571CrossRefPubMed
7.
go back to reference Cardinale F, Rizzi M, D’Orio P, Casaceli G, Arnulfo G, Narizzano M, Scorza D, De Momi E, Nichelatti M, Redaelli D, Sberna M, Moscato A, Castana L (2017) A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series. Neurosurg Focus 42:E8CrossRefPubMed Cardinale F, Rizzi M, D’Orio P, Casaceli G, Arnulfo G, Narizzano M, Scorza D, De Momi E, Nichelatti M, Redaelli D, Sberna M, Moscato A, Castana L (2017) A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series. Neurosurg Focus 42:E8CrossRefPubMed
9.
go back to reference Altman DG (1994) The scandal of poor medical research. Br Med J 308:283–284CrossRef Altman DG (1994) The scandal of poor medical research. Br Med J 308:283–284CrossRef
Metadata
Title
Stereotactic accuracy must be as high as possible in stereoelectroencephalography procedures
Authors
Francesco Cardinale
Michele Rizzi
Publication date
01-12-2017
Publisher
Springer London
Published in
Journal of Robotic Surgery / Issue 4/2017
Print ISSN: 1863-2483
Electronic ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-017-0723-z

Other articles of this Issue 4/2017

Journal of Robotic Surgery 4/2017 Go to the issue