01-05-2005 | Clinical Research

Static Mechanical Properties of Custom-Made Aortic Endografts

Authors: Jean-Dominique Singland, MD, Julie Voulgre, PhD, Gregory Picard, PhD, David Mitton, PhD, Philippe Cluzel, MD, Francois Lavaste, PhD, Edouard Kieffer, MD, Fabien Koskas, MD

Published in: Annals of Vascular Surgery | Issue 3/2005

Login to get access

Abstract

Several cases of delayed aortic rupture after endovascular aneurysm repair have been attributed to in vivo endograft fatigue. Such complications could involve damage to structural components during introduction. The purpose of this study was to compare forces applied during introduction to forces needed to damage the endograft. Testing was carried out on the custom-made endograft (CMEG) that has been in almost exclusive use at our center since 1996. Findings showed that the force applied during introduction was less than the force necessary to damage the endograft. No alteration in the mechanical properties of the CMEG was observed immediately after implantation.
Literature
1.
go back to reference Lumsden, AB, Alien, RC, Chaikof, EL, et al. 1995Delayed rupture of aortic aneurysms following endovascular stent graftingAm J Surg170174178CrossRefPubMed Lumsden, AB, Alien, RC, Chaikof, EL,  et al. 1995Delayed rupture of aortic aneurysms following endovascular stent graftingAm J Surg170174178CrossRefPubMed
2.
go back to reference Torsello, GB, Klenk, E, Kasprzak, B, Umscheid, T 1998Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraftJ Vasc Surg28184187PubMed Torsello, GB, Klenk, E, Kasprzak, B, Umscheid, T 1998Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraftJ Vasc Surg28184187PubMed
3.
go back to reference Alimi, YS, Chakfe, N, Rivoal, E, et al. 1998Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reductionJ Vasc Surg28178183PubMed Alimi, YS, Chakfe, N, Rivoal, E,  et al. 1998Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reductionJ Vasc Surg28178183PubMed
4.
go back to reference Midorikawa, H, Hoshino, S, Iwaia, F, Igari, T 1999Graft wall on the leak 18 months after successful endoluminal AAA repairJ Endovasc Surg6251255CrossRefPubMed Midorikawa, H, Hoshino, S, Iwaia, F, Igari, T 1999Graft wall on the leak 18 months after successful endoluminal AAA repairJ Endovasc Surg6251255CrossRefPubMed
5.
go back to reference Bohm, T, Soldner, J, Rott, A, Kaiser, WA 1999Perigraft leak of an aortic stent graft due to material fatigueA.J.R., Am J Roentgenol17213551357 Bohm, T, Soldner, J, Rott, A, Kaiser, WA 1999Perigraft leak of an aortic stent graft due to material fatigueA.J.R., Am J Roentgenol17213551357
6.
go back to reference Umscheid, T, Stelter, WJ 1999Time related alteration in shape position and structure of self-expanding, modular aortic stent grafts: a four year single center follow-upJ. Endovasc. Surg61732CrossRefPubMed Umscheid, T, Stelter, WJ 1999Time related alteration in shape position and structure of self-expanding, modular aortic stent grafts: a four year single center follow-upJ. Endovasc. Surg61732CrossRefPubMed
7.
go back to reference Zarins, CZ, White, RA, Fogarty, TJ 2000Aneurysm rupture after endovascular repair using the AneuRx stent graftJ Vasc Surg31960970CrossRefPubMed Zarins, CZ, White, RA, Fogarty, TJ 2000Aneurysm rupture after endovascular repair using the AneuRx stent graftJ Vasc Surg31960970CrossRefPubMed
8.
go back to reference Politz, JK, Newman, VS, Stewart, MT 2000Late abdominal aortic aneurysm rupture after AneuRx repair: a report of three casesJ Vasc Surg31599606CrossRefPubMed Politz, JK, Newman, VS, Stewart, MT 2000Late abdominal aortic aneurysm rupture after AneuRx repair: a report of three casesJ Vasc Surg31599606CrossRefPubMed
9.
go back to reference Bernhard, VM, Mitchell, RS, Matsumara, JS, et al. 2002Ruptured abdominal aortic aneurysm after endovascular repairJ Vasc Surg3512991300CrossRefPubMed Bernhard, VM, Mitchell, RS, Matsumara, JS,  et al. 2002Ruptured abdominal aortic aneurysm after endovascular repairJ Vasc Surg3512991300CrossRefPubMed
10.
go back to reference Koskas, F, Cluzel, P, Benhamou, AC, Kieffer, E 1999Endovascular treatment of aortoiliac aneurysm: made-to-measure stent graft increase feasibilityAnn Vasc Surg13239246CrossRefPubMed Koskas, F, Cluzel, P, Benhamou, AC, Kieffer, E 1999Endovascular treatment of aortoiliac aneurysm: made-to-measure stent graft increase feasibilityAnn Vasc Surg13239246CrossRefPubMed
Metadata
Title
Static Mechanical Properties of Custom-Made Aortic Endografts
Authors
Jean-Dominique Singland, MD
Julie Voulgre, PhD
Gregory Picard, PhD
David Mitton, PhD
Philippe Cluzel, MD
Francois Lavaste, PhD
Edouard Kieffer, MD
Fabien Koskas, MD
Publication date
01-05-2005
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 3/2005
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-005-0014-4

Other articles of this Issue 3/2005

Annals of Vascular Surgery 3/2005 Go to the issue