Skip to main content
Top
Published in: Journal of Gastrointestinal Surgery 3/2007

01-03-2007

Staple Line Reinforcement Reduces Postoperative Pancreatic Stump Leak After Distal Pancreatectomy

Authors: Ramon E. Jimenez, Arun Mavanur, William P. Macaulay

Published in: Journal of Gastrointestinal Surgery | Issue 3/2007

Login to get access

Abstract

Pancreatic stump leak is the major source of morbidity after stapled distal pancreatectomy. We hypothesized that reinforcement of the stapler system with a buttress mat can improve leak rates when compared to standard stapling alone. We performed 13 consecutive distal pancreatectomies using our reinforced stapler system, forming our experimental group. A historical control group was composed of 18 patients undergoing stapled pancreatic closure without reinforcement. The main outcome measure was pancreatic leak in the postoperative period. Pancreatic leaks included fistulas and fluid collections (sterile or infected). Hospital length of stay was recorded as a secondary measure. Postoperative pancreatic leak rate was zero in the experimental group, but 39% in the control group (P = 0.025). Development of a pancreatic leak resulted in prolonged hospital stays: 13.6 vs 8.3 days (P < 0.03). We conclude that staple line reinforcement is a simple and effective method of reducing pancreatic stump leakage after distal pancreatectomy. The economic impact of lower leak rates is reflected in significantly shorter hospital stays. The results of our study should be validated in a randomized controlled trial.
Literature
1.
go back to reference Bilimoria, M. M., Cormier, J. N., Mun, Y., Lee, J. E., Evans, D. B., & Pisters, P. W. (2003). Pancreatic leak after left pancreatectomy is reduced following main pancreatic duct ligation. British Journal of Surgery, 90(2), 190–196.PubMedCrossRef Bilimoria, M. M., Cormier, J. N., Mun, Y., Lee, J. E., Evans, D. B., & Pisters, P. W. (2003). Pancreatic leak after left pancreatectomy is reduced following main pancreatic duct ligation. British Journal of Surgery, 90(2), 190–196.PubMedCrossRef
2.
go back to reference Pachter, H. L., Pennington, R., Chassin, J., & Spencer, F. C. (1979) Simplified distal pancreatectomy with the Auto Suture stapler: preliminary clinical observations. Surgery, 85(2), 166–170.PubMed Pachter, H. L., Pennington, R., Chassin, J., & Spencer, F. C. (1979) Simplified distal pancreatectomy with the Auto Suture stapler: preliminary clinical observations. Surgery, 85(2), 166–170.PubMed
3.
go back to reference Connor, S., Alexakis, N., Garden, O. J., Leandros, E., Bramis, J., & Wigmore, S. J. (2005). Meta-analysis of the value of somatostatin and its analogues in reducing complications associated with pancreatic surgery. British Journal of Surgery, 92(9), 1059–1067.PubMedCrossRef Connor, S., Alexakis, N., Garden, O. J., Leandros, E., Bramis, J., & Wigmore, S. J. (2005). Meta-analysis of the value of somatostatin and its analogues in reducing complications associated with pancreatic surgery. British Journal of Surgery, 92(9), 1059–1067.PubMedCrossRef
4.
go back to reference Suc, B., Msika, S., Fingerhut, A., Fourtanier, G., Hay, J. M., Holmieres, F., et al. (2003). Temporary fibrin glue occlusion of the main pancreatic duct in the prevention of intra-abdominal complications after pancreatic resection: prospective randomized trial. Annals of Surgery, 237(1), 57–65.PubMedCrossRef Suc, B., Msika, S., Fingerhut, A., Fourtanier, G., Hay, J. M., Holmieres, F., et al. (2003). Temporary fibrin glue occlusion of the main pancreatic duct in the prevention of intra-abdominal complications after pancreatic resection: prospective randomized trial. Annals of Surgery, 237(1), 57–65.PubMedCrossRef
5.
go back to reference Suzuki, Y., Kuroda, Y., Morita, A., Fujino, Y., Tanioka, Y., Kawamura, T., et al. (1995). Fibrin glue sealing for the prevention of pancreatic fistulas following distal pancreatectomy. Archives of Surgery, 130(9), 952–955.PubMed Suzuki, Y., Kuroda, Y., Morita, A., Fujino, Y., Tanioka, Y., Kawamura, T., et al. (1995). Fibrin glue sealing for the prevention of pancreatic fistulas following distal pancreatectomy. Archives of Surgery, 130(9), 952–955.PubMed
6.
go back to reference Abe, N., Sugiyama, M., Suzuki, Y., Yamaguchi, Y., Yanagida, O., Masaki, T., et al. (2006). Preoperative endoscopic pancreatic stenting for prophylaxis of pancreatic fistula development after distal pancreatectomy. American Journal of Surgery, 191(2), 198–200.PubMedCrossRef Abe, N., Sugiyama, M., Suzuki, Y., Yamaguchi, Y., Yanagida, O., Masaki, T., et al. (2006). Preoperative endoscopic pancreatic stenting for prophylaxis of pancreatic fistula development after distal pancreatectomy. American Journal of Surgery, 191(2), 198–200.PubMedCrossRef
7.
go back to reference Knaebel, H. P., Diener, M. K., Wentem M. N., Buchler, M. W., & Seiler, C. M. (2005). Systematic review and meta-analysis of technique for closure of the pancreatic remnant after distal pancreatectomy. British Journal of Surgery, 92(5), 539–546.PubMedCrossRef Knaebel, H. P., Diener, M. K., Wentem M. N., Buchler, M. W., & Seiler, C. M. (2005). Systematic review and meta-analysis of technique for closure of the pancreatic remnant after distal pancreatectomy. British Journal of Surgery, 92(5), 539–546.PubMedCrossRef
8.
go back to reference D’Angelica, M., Are, C., Jarnagin, W., DeGregoris, G., Coit, D., Jaques, D., et al. (2006). Initial experience with hand-assisted laparoscopic distal pancreatectomy. Surgical Endoscopy, 20(1), 142–148.PubMedCrossRef D’Angelica, M., Are, C., Jarnagin, W., DeGregoris, G., Coit, D., Jaques, D., et al. (2006). Initial experience with hand-assisted laparoscopic distal pancreatectomy. Surgical Endoscopy, 20(1), 142–148.PubMedCrossRef
9.
go back to reference Balcom, J. H., Rattner, D. W., Warshaw, A. L., Chang, Y., & Fernandez-del Castillo, C. (2001). Ten-year experience with 733 pancreatic resections: changing indications, older patients, and decreasing length of hospitalization. Archives of Surgery, 136(4), 391–398.PubMedCrossRef Balcom, J. H., Rattner, D. W., Warshaw, A. L., Chang, Y., & Fernandez-del Castillo, C. (2001). Ten-year experience with 733 pancreatic resections: changing indications, older patients, and decreasing length of hospitalization. Archives of Surgery, 136(4), 391–398.PubMedCrossRef
10.
go back to reference Buchler, M. W., Friess, H., Wagner, M., Kulli, C., Wagener, V., & Z’Graggen, K. (2000). Pancreatic fistula after pancreatic head resection. British Journal of Surgery, 87(7), 883–889.PubMedCrossRef Buchler, M. W., Friess, H., Wagner, M., Kulli, C., Wagener, V., & Z’Graggen, K. (2000). Pancreatic fistula after pancreatic head resection. British Journal of Surgery, 87(7), 883–889.PubMedCrossRef
11.
go back to reference Kazanjian, K. K., Hines, O. J., Eibl, G., & Reber, H. A.(2005). Management of pancreatic fistulas after pancreaticoduodenectomy: results in 437 consecutive patients. Archives of Surgery, 140(9), 849–854.PubMedCrossRef Kazanjian, K. K., Hines, O. J., Eibl, G., & Reber, H. A.(2005). Management of pancreatic fistulas after pancreaticoduodenectomy: results in 437 consecutive patients. Archives of Surgery, 140(9), 849–854.PubMedCrossRef
12.
go back to reference Bassi, C., Falconi, M., Salvia, R., Mascetta, G., Molinari, E., & Pederzoli, P. (2001). Management of complications after pancreaticoduodenectomy in a high volume centre: results on 150 consecutive patients. Digestive Surgery, 18(6), 453–457.PubMedCrossRef Bassi, C., Falconi, M., Salvia, R., Mascetta, G., Molinari, E., & Pederzoli, P. (2001). Management of complications after pancreaticoduodenectomy in a high volume centre: results on 150 consecutive patients. Digestive Surgery, 18(6), 453–457.PubMedCrossRef
13.
go back to reference Lin, J. W., Cameron, J. L., Yeo, C. J., Riall, T. S., & Lillemoe, K. D. (2004). Risk factors and outcomes in postpancreaticoduodenectomy pancreaticocutaneous fistula. Journal of Gastrointestinal Surgery, 8(8), 951–959.PubMedCrossRef Lin, J. W., Cameron, J. L., Yeo, C. J., Riall, T. S., & Lillemoe, K. D. (2004). Risk factors and outcomes in postpancreaticoduodenectomy pancreaticocutaneous fistula. Journal of Gastrointestinal Surgery, 8(8), 951–959.PubMedCrossRef
14.
go back to reference Arnold, W., & Shikora, S. A. (2005). A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model. Obesity Surgery, 15(2), 164–171.PubMedCrossRef Arnold, W., & Shikora, S. A. (2005). A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model. Obesity Surgery, 15(2), 164–171.PubMedCrossRef
15.
go back to reference Downey, D. M., Michel, M., Harre, J. G., & Pratt, J. W. (2006). Functional assessment of a new staple line reinforcement in lung resection. Journal of Surgical Research, 131(1), 49–52.PubMedCrossRef Downey, D. M., Michel, M., Harre, J. G., & Pratt, J. W. (2006). Functional assessment of a new staple line reinforcement in lung resection. Journal of Surgical Research, 131(1), 49–52.PubMedCrossRef
Metadata
Title
Staple Line Reinforcement Reduces Postoperative Pancreatic Stump Leak After Distal Pancreatectomy
Authors
Ramon E. Jimenez
Arun Mavanur
William P. Macaulay
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
Journal of Gastrointestinal Surgery / Issue 3/2007
Print ISSN: 1091-255X
Electronic ISSN: 1873-4626
DOI
https://doi.org/10.1007/s11605-006-0034-6

Other articles of this Issue 3/2007

Journal of Gastrointestinal Surgery 3/2007 Go to the issue