Skip to main content
Top
Published in: BMC Medical Imaging 1/2012

Open Access 01-12-2012 | Technical advance

Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

Authors: Michael T Hirschmann, Christopher R Wagner, Helmut Rasch, Johann Henckel

Published in: BMC Medical Imaging | Issue 1/2012

Login to get access

Abstract

Background

SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions.

Methods

We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity.

Results

Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology.

Conclusions

Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD: SPECT/CT imaging: clinical utility of an emerging technology. Radiographics. 2008, 28: 1097-1113.CrossRefPubMed Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD: SPECT/CT imaging: clinical utility of an emerging technology. Radiographics. 2008, 28: 1097-1113.CrossRefPubMed
2.
go back to reference Patton JA, Turkington TG: SPECT/CT physical principles and attenuation correction. J Nucl Med Technol. 2008, 36: 1-10.CrossRefPubMed Patton JA, Turkington TG: SPECT/CT physical principles and attenuation correction. J Nucl Med Technol. 2008, 36: 1-10.CrossRefPubMed
3.
go back to reference Schillaci O: Hybrid SPECT/CT: a new era for SPECT imaging?. Eur J Nucl Med Mol Imaging. 2005, 32: 521-524.CrossRefPubMed Schillaci O: Hybrid SPECT/CT: a new era for SPECT imaging?. Eur J Nucl Med Mol Imaging. 2005, 32: 521-524.CrossRefPubMed
4.
go back to reference O'Connor MK, Kemp BJ: Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations. Semin Nucl Med. 2006, 36: 258-266.CrossRefPubMed O'Connor MK, Kemp BJ: Single-photon emission computed tomography/computed tomography: basic instrumentation and innovations. Semin Nucl Med. 2006, 36: 258-266.CrossRefPubMed
5.
go back to reference Bernstein MP, Caldwell CB, Antonyshyn OM, Cooper PW, Ehrlich LE: Spatial and temporal registration of CT and SPECT images: development and validation of a technique for in vivo three-dimensional semiquantitative analysis of bone. J Nucl Med. 2000, 41: 1075-1081.PubMed Bernstein MP, Caldwell CB, Antonyshyn OM, Cooper PW, Ehrlich LE: Spatial and temporal registration of CT and SPECT images: development and validation of a technique for in vivo three-dimensional semiquantitative analysis of bone. J Nucl Med. 2000, 41: 1075-1081.PubMed
6.
go back to reference Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, Chisin R: Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med. 2000, 27: 619-627.CrossRefPubMed Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, Chisin R: Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med. 2000, 27: 619-627.CrossRefPubMed
7.
go back to reference Agriantonis DJ, Hall L, Wilson MA: Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med. 2009, 34: 247-248.CrossRefPubMed Agriantonis DJ, Hall L, Wilson MA: Utility of SPECT/CT as an adjunct to planar whole body I-131 imaging: liver metastasis from papillary thyroid cancer. Clin Nucl Med. 2009, 34: 247-248.CrossRefPubMed
8.
go back to reference Akincioglu C, Belhocine T, Gambhir S, Romsa J, Chouraiki G, Kribs S, Elliot JA, Vezina W, Urbain JL: Complementary roles of low-dose SPECT-CT and high-resolution volume CT for detection of coronary artery disease. Clin Nucl Med. 2008, 33: 285-287.CrossRefPubMed Akincioglu C, Belhocine T, Gambhir S, Romsa J, Chouraiki G, Kribs S, Elliot JA, Vezina W, Urbain JL: Complementary roles of low-dose SPECT-CT and high-resolution volume CT for detection of coronary artery disease. Clin Nucl Med. 2008, 33: 285-287.CrossRefPubMed
9.
go back to reference Even-Sapir E, Keidar Z, Bar-Shalom R: Hybrid Imaging (SPECT/CT and PET/CT)-improving the diagnostic accuracy of functional/metabolic and anatomic imaging. Semin Nucl Med. 2009, 39: 264-275.CrossRefPubMed Even-Sapir E, Keidar Z, Bar-Shalom R: Hybrid Imaging (SPECT/CT and PET/CT)-improving the diagnostic accuracy of functional/metabolic and anatomic imaging. Semin Nucl Med. 2009, 39: 264-275.CrossRefPubMed
10.
go back to reference Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF: Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons?. Knee Surg Sports Traumatol Arthrosc. 2009, 18: 341-345.CrossRefPubMed Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF: Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons?. Knee Surg Sports Traumatol Arthrosc. 2009, 18: 341-345.CrossRefPubMed
11.
go back to reference Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF: A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010, 18: 939-44.CrossRefPubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF: A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010, 18: 939-44.CrossRefPubMed
12.
go back to reference Blake GM, Frost ML, Fogelman I: Quantitative radionuclide studies of bone. J Nucl Med. 2009, 50: 1747-1750.CrossRefPubMed Blake GM, Frost ML, Fogelman I: Quantitative radionuclide studies of bone. J Nucl Med. 2009, 50: 1747-1750.CrossRefPubMed
13.
go back to reference Blake GM, Moore AE, Fogelman I: Quantitative studies of bone using (99m)Tc-methylene diphosphonate skeletal plasma clearance. Semin Nucl Med. 2009, 39: 369-379.CrossRefPubMed Blake GM, Moore AE, Fogelman I: Quantitative studies of bone using (99m)Tc-methylene diphosphonate skeletal plasma clearance. Semin Nucl Med. 2009, 39: 369-379.CrossRefPubMed
14.
go back to reference Filippi L, Manni C, Pierantozzi M, Brusa L, Danieli R, Stanzione P, Schillaci O: 123I-FP-CIT semi-quantitative SPECT detects preclinical bilateral dopaminergic deficit in early Parkinson's disease with unilateral symptoms. Nucl Med Commun. 2005, 26: 421-426.CrossRefPubMed Filippi L, Manni C, Pierantozzi M, Brusa L, Danieli R, Stanzione P, Schillaci O: 123I-FP-CIT semi-quantitative SPECT detects preclinical bilateral dopaminergic deficit in early Parkinson's disease with unilateral symptoms. Nucl Med Commun. 2005, 26: 421-426.CrossRefPubMed
15.
go back to reference Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E, Rudoni M, Inglese E, Cannas M: Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res. 1996, 325: 181-189.CrossRefPubMed Sacchetti GM, Ghisellini F, Brambilla M, De Consoli A, Fornara P, Rizzo E, Rudoni M, Inglese E, Cannas M: Quantitative scintigraphic evaluation of total knee arthroplasties: a feasibility study. Clin Orthop Relat Res. 1996, 325: 181-189.CrossRefPubMed
16.
go back to reference Shiraishi S, Tomiguchi S, Utsunomiya D, Kawanaka K, Awai K, Morishita S, Okuda T, Yokotsuka K, Yamashita Y: Quantitative analysis and effect of attenuation correction on lymph node staging of non-small cell lung cancer on SPECT and CT. AJR Am J Roentgenol. 2006, 186: 1450-1457.CrossRefPubMed Shiraishi S, Tomiguchi S, Utsunomiya D, Kawanaka K, Awai K, Morishita S, Okuda T, Yokotsuka K, Yamashita Y: Quantitative analysis and effect of attenuation correction on lymph node staging of non-small cell lung cancer on SPECT and CT. AJR Am J Roentgenol. 2006, 186: 1450-1457.CrossRefPubMed
17.
go back to reference Pennock GR, Clark KJ: An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. J Biomech. 1990, 23: 1209-1218.CrossRefPubMed Pennock GR, Clark KJ: An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. J Biomech. 1990, 23: 1209-1218.CrossRefPubMed
18.
go back to reference Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP: Comparison of inter- and intra-observer reliability of component position measurements in total knee arthroplasty on conventional radiographs, transverse 2D-CT slices and 3D-CT. J Bone Joint Surg Br. 2010, 93: 629-633. Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP: Comparison of inter- and intra-observer reliability of component position measurements in total knee arthroplasty on conventional radiographs, transverse 2D-CT slices and 3D-CT. J Bone Joint Surg Br. 2010, 93: 629-633.
19.
go back to reference Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR, Cobb JP: Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg Br. 2006, 88: 1513-1518.CrossRefPubMed Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR, Cobb JP: Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg Br. 2006, 88: 1513-1518.CrossRefPubMed
20.
go back to reference Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF: Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop. 2011, 35: 675-680.CrossRefPubMed Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF: Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop. 2011, 35: 675-680.CrossRefPubMed
21.
go back to reference Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF: Clinical value of SPECT-CT for evaluation of patients with painful knees after total knee arthroplasty - a new dimension of diagnostics. BMC Musculoskelet Disord. 2011, 12: 36-CrossRefPubMedPubMedCentral Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF: Clinical value of SPECT-CT for evaluation of patients with painful knees after total knee arthroplasty - a new dimension of diagnostics. BMC Musculoskelet Disord. 2011, 12: 36-CrossRefPubMedPubMedCentral
22.
go back to reference Hirschmann MT, Adler T, Rasch H, Hugli RW, Friederich NF, Arnold MP: Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol. 2: 24- Hirschmann MT, Adler T, Rasch H, Hugli RW, Friederich NF, Arnold MP: Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol. 2: 24-
23.
go back to reference Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT: Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 24: 621-624. Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT: Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 24: 621-624.
Metadata
Title
Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis
Authors
Michael T Hirschmann
Christopher R Wagner
Helmut Rasch
Johann Henckel
Publication date
01-12-2012
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2012
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/1471-2342-12-5

Other articles of this Issue 1/2012

BMC Medical Imaging 1/2012 Go to the issue