Skip to main content
Top
Published in: Journal of Artificial Organs 3/2014

01-09-2014 | Case Report

Staged and effortless explantation of CircuLite Synergy micropump

Authors: Prashant N. Mohite, Anton Sabashnikov, Diana Garcia, Bartlomeij Zych, Andre R. Simon

Published in: Journal of Artificial Organs | Issue 3/2014

Login to get access

Abstract

Synergy® micropump was implanted as a bridge to heart transplantation in a middle-age lady with chronic advanced heart failure due to dilated cardiomyopathy. After a good initial recovery, patient was discharged to ward, where her stay was prolonged due to non-healing operative wound over the micropump and recurrent gastrointestinal bleeding. After 3 months of therapy, the heart seemed to be recovered and the micropump was explanted. In view of the patient’s bleeding tendency, the micropump was explanted in staged manner.
Literature
1.
go back to reference Frazier OH, Rose EA, Oz MC, et al. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovasc Surg. 2001;122:1186–95.PubMedCrossRef Frazier OH, Rose EA, Oz MC, et al. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovasc Surg. 2001;122:1186–95.PubMedCrossRef
2.
go back to reference Meyns B, Simon A, Klotz S, Wittwer T, Schlensak C, Rega F, Burkhoff D. Clinical benefits of partial circulatory support in New York heart association class IIIb and early class IV patients. Eur J Cardiothorac Surg. 2011;39:693–8.PubMedCrossRef Meyns B, Simon A, Klotz S, Wittwer T, Schlensak C, Rega F, Burkhoff D. Clinical benefits of partial circulatory support in New York heart association class IIIb and early class IV patients. Eur J Cardiothorac Surg. 2011;39:693–8.PubMedCrossRef
4.
go back to reference Birks EJ, Yacoub MH, Banner NR, Khaghani A. The role of bridge to transplantation: should LVAD patients be transplanted? Curr Opin Cardiol. 2004;19:148–53.PubMedCrossRef Birks EJ, Yacoub MH, Banner NR, Khaghani A. The role of bridge to transplantation: should LVAD patients be transplanted? Curr Opin Cardiol. 2004;19:148–53.PubMedCrossRef
5.
go back to reference Aissaoui N, Börgermann J, Gummert J, Morshuis M. HeartWare continuous-flow ventricular assist device thrombosis: the Bad Oeynhausen experience. J Thorac Cardiovasc Surg. 2012;143:e37–9.PubMedCrossRef Aissaoui N, Börgermann J, Gummert J, Morshuis M. HeartWare continuous-flow ventricular assist device thrombosis: the Bad Oeynhausen experience. J Thorac Cardiovasc Surg. 2012;143:e37–9.PubMedCrossRef
6.
go back to reference Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ, et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009;54:312–21.PubMedCrossRef
Metadata
Title
Staged and effortless explantation of CircuLite Synergy micropump
Authors
Prashant N. Mohite
Anton Sabashnikov
Diana Garcia
Bartlomeij Zych
Andre R. Simon
Publication date
01-09-2014
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 3/2014
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-014-0763-3

Other articles of this Issue 3/2014

Journal of Artificial Organs 3/2014 Go to the issue