Skip to main content
Top
Published in: BMC Surgery 1/2014

Open Access 01-12-2014 | Case report

Spontaneous complete migration of suture material after subcuticular continuous suture in cesarean section: a case report

Authors: Ki-Jin Ryu, Ki Hoon Ahn, Soon Cheol Hong

Published in: BMC Surgery | Issue 1/2014

Login to get access

Abstract

Background

Skin closure during cesarean section is often performed with subcuticular running sutures by using a nonabsorbable suture material. However, this material has the risk of incomplete removal after wound healing and can migrate to other sites in rare cases.

Case presentation

A 34-year-old Korean woman who had undergone a cesarean section 5 months prior presented with a fine, blue object visible through the skin on her left lower abdomen. No pain or any other signs of inflammation were observed. The foreign body was revealed to be 10-cm-long suture material that had migrated laterally approximately 15 cm in intradermal layer during the previous 5 months, without tangling of the entire length.

Conclusions

Small remnants of suture materials in the subcutaneous tissue are known to migrate toward the superficial layer. The mechanism of these migrations is often thought to be related to foreign body immune reaction or the force generated in wound contracture. Long-distance migration of relatively long suture materials, as in the present case, has not been reported yet. Such a steady tension in a uniform direction within a human tissue layer cannot be explained clearly by the previously described mechanisms. That migration might have occurred in superficial subcutaneous tissue layers through the horizontal flow or movement of those layers during the recovery process that have not been revealed yet.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tuuli MG, Rampersad RM, Carbone JF, Stamilio D, Macones GA, Odibo AO: Staples compared with subcuticular suture for skin closure after cesarean delivery: a systematic review and meta-analysis. Obstet Gynecol. 2011, 117 (3): 682-690. 10.1097/AOG.0b013e31820ad61e.CrossRefPubMed Tuuli MG, Rampersad RM, Carbone JF, Stamilio D, Macones GA, Odibo AO: Staples compared with subcuticular suture for skin closure after cesarean delivery: a systematic review and meta-analysis. Obstet Gynecol. 2011, 117 (3): 682-690. 10.1097/AOG.0b013e31820ad61e.CrossRefPubMed
2.
go back to reference Genders RE, Hamminga EA, Kukutsch NA: Securing the subcuticular running suture. Dermatol Surg. 2012, 38 (10): 1722-1724. 10.1111/j.1524-4725.2012.02488.x.CrossRefPubMed Genders RE, Hamminga EA, Kukutsch NA: Securing the subcuticular running suture. Dermatol Surg. 2012, 38 (10): 1722-1724. 10.1111/j.1524-4725.2012.02488.x.CrossRefPubMed
3.
go back to reference Foster JA, John KB, Castro E, Meisler DM: Blepharoptosis surgery complicated by late suture migration. Am J Ophthalmol. 2000, 130 (1): 116-117. 10.1016/S0002-9394(00)00467-0.CrossRefPubMed Foster JA, John KB, Castro E, Meisler DM: Blepharoptosis surgery complicated by late suture migration. Am J Ophthalmol. 2000, 130 (1): 116-117. 10.1016/S0002-9394(00)00467-0.CrossRefPubMed
5.
go back to reference Nagasaka T, Inao S, Ikeda H, Tsugeno M, Okamoto T: Subcutaneous migration of distal ventriculoperitoneal shunt catheter caused by abdominal fat pad shift: three case reports. Neurol Med Chir. 2010, 50 (1): 80-82. 10.2176/nmc.50.80.CrossRef Nagasaka T, Inao S, Ikeda H, Tsugeno M, Okamoto T: Subcutaneous migration of distal ventriculoperitoneal shunt catheter caused by abdominal fat pad shift: three case reports. Neurol Med Chir. 2010, 50 (1): 80-82. 10.2176/nmc.50.80.CrossRef
6.
go back to reference Junqueira LCUA, Carneiro J, Contopoulos AN: Basic histology. A concise medical library for practitioner and student. 1975, Los Altos: Calif.: Lange Medical Publications, v Junqueira LCUA, Carneiro J, Contopoulos AN: Basic histology. A concise medical library for practitioner and student. 1975, Los Altos: Calif.: Lange Medical Publications, v
Metadata
Title
Spontaneous complete migration of suture material after subcuticular continuous suture in cesarean section: a case report
Authors
Ki-Jin Ryu
Ki Hoon Ahn
Soon Cheol Hong
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2014
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/1471-2482-14-103

Other articles of this Issue 1/2014

BMC Surgery 1/2014 Go to the issue