Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2011

01-06-2011 | Knee

Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty

Authors: Tomoyuki Matsumoto, Hirotsugu Muratsu, Seiji Kubo, Kiyonori Mizuno, Keisuke Kinoshita, Kazunari Ishida, Takehiko Matsushita, Ken Sasaki, Katsumasa Tei, Koji Takayama, Hiroshi Sasaki, Shinya Oka, Masahiro Kurosaka, Ryosuke Kuroda

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2011

Login to get access

Abstract

Purposes

Minimal incision surgery (MIS) total knee arthroplasty (TKA) is widely promoted as a possible improvement over conventional TKA, and accurate implantations have recently been reported using navigation systems. However, soft tissue balance during MIS-TKA remains challenging. Therefore, in this report, joint gap (component gap) and ligament balance (varus angle) were assessed during MIS-TKA using a tensor, which enables soft tissue balance assessment with a reduced patellofemoral joint and femoral component in place.

Methods

Results were compared to those of conventional TKA. Posterior stabilized TKA were performed in 50 knees (25 knees: MIS-TKA using quadriceps-sparing approach; 25 knees: conventional TKA using medial parapatellar approach) with varus osteoarthritis. Component gap and varus angle were measured using the tensor with a reduced patellofemoral joint at 0, 10, 45, 90, and 135°.

Results

Whereas the component gap in MIS-TKA was significantly larger through the entire arc of flexion compared with conventional TKA, the pattern of joint looseness showed no difference between the two procedures. The varus angle in MIS-TKA was significantly larger than that in conventional TKA at 0, 90, and 135° of knee flexion.

Conclusions

MIS-TKA may lead to ligament imbalance due to the difficulties induced by a limited working space. Understanding this pattern allows surgeons to be able to adjust the soft tissue balance more accurately and thereby expect a better post-operative outcome even in MIS-TKA.
Literature
1.
go back to reference Aglietti P, Baldini A, Sensi L (2006) Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res 452:106–111PubMedCrossRef Aglietti P, Baldini A, Sensi L (2006) Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res 452:106–111PubMedCrossRef
2.
go back to reference Boerger TO, Aglietti P, Mondanelli N, Sensi L (2005) Mini-subvastus versus medial parapatellar approach in total knee arthroplasty. Clin Orthop Relat Res 440:82–87PubMedCrossRef Boerger TO, Aglietti P, Mondanelli N, Sensi L (2005) Mini-subvastus versus medial parapatellar approach in total knee arthroplasty. Clin Orthop Relat Res 440:82–87PubMedCrossRef
3.
go back to reference Bonutti PM, Mont MA, McMahon M, Ragland PS, Kester M (2004) Minimally invasive total knee arthroplasty. J Bone Joint Surg Am 86:26–32PubMed Bonutti PM, Mont MA, McMahon M, Ragland PS, Kester M (2004) Minimally invasive total knee arthroplasty. J Bone Joint Surg Am 86:26–32PubMed
4.
go back to reference Chen AF, Alan RK, Redziniak DE, Tria AJ Jr (2006) Quadriceps sparing total knee replacement. The initial experience with results at two to four years. J Bone Joint Surg Br 88:1448–1453PubMed Chen AF, Alan RK, Redziniak DE, Tria AJ Jr (2006) Quadriceps sparing total knee replacement. The initial experience with results at two to four years. J Bone Joint Surg Br 88:1448–1453PubMed
5.
go back to reference Dalury DF, Dennis DA (2005) Mini-incision total knee arthroplasty can increase risk of component malalignment. Clin Orthop Relat Res 440:77–81PubMedCrossRef Dalury DF, Dennis DA (2005) Mini-incision total knee arthroplasty can increase risk of component malalignment. Clin Orthop Relat Res 440:77–81PubMedCrossRef
6.
go back to reference Dennis DA (2008) Measured resection: an outdated technique in total knee arthroplasty. Orthopedics 31(940):943–944 Dennis DA (2008) Measured resection: an outdated technique in total knee arthroplasty. Orthopedics 31(940):943–944
7.
go back to reference Fehring TK (2000) Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79PubMedCrossRef Fehring TK (2000) Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79PubMedCrossRef
8.
go back to reference Freeman MA, Todd RC, Bamert P, Day WH (1978) ICLH arthroplasty of the knee: 1968–1977. J Bone Joint Surg Br 60:339–344PubMed Freeman MA, Todd RC, Bamert P, Day WH (1978) ICLH arthroplasty of the knee: 1968–1977. J Bone Joint Surg Br 60:339–344PubMed
9.
go back to reference Hanada H, Whiteside LA, Steiger J, Dyer P, Naito M (2007) Bone landmarks are more reliable than tensioned gaps in TKA component alignment. Clin Orthop Relat Res 462:137–142PubMedCrossRef Hanada H, Whiteside LA, Steiger J, Dyer P, Naito M (2007) Bone landmarks are more reliable than tensioned gaps in TKA component alignment. Clin Orthop Relat Res 462:137–142PubMedCrossRef
10.
go back to reference Hass SB, Cook S, Beksac B (2004) Minimally invasive total knee replacement through a mini midvastus approach: a comparative study. Clin Orthop Relat Res 428:68–73CrossRef Hass SB, Cook S, Beksac B (2004) Minimally invasive total knee replacement through a mini midvastus approach: a comparative study. Clin Orthop Relat Res 428:68–73CrossRef
11.
go back to reference Kashyap SN, Van Ommeren JW (2008) Clinical experience with less invasive surgery techniques in total knee arthroplasty: a comparative study. Knee Surg Sports Traumatol Arthrosc 16:544–548PubMedCrossRef Kashyap SN, Van Ommeren JW (2008) Clinical experience with less invasive surgery techniques in total knee arthroplasty: a comparative study. Knee Surg Sports Traumatol Arthrosc 16:544–548PubMedCrossRef
12.
go back to reference Kolisek FR, Bonutti PM, Hazack WJ, Purtill J, Sharkey PF, Zelicof SB, Ragland PS, Kester M, Mont MA, Rothman RH (2007) Clinical experience using a minimally invasive approach for total knee arthroplasty: early results of a prospective randomized study compared to a standard approach. J Arthroplasty 22:8–13PubMedCrossRef Kolisek FR, Bonutti PM, Hazack WJ, Purtill J, Sharkey PF, Zelicof SB, Ragland PS, Kester M, Mont MA, Rothman RH (2007) Clinical experience using a minimally invasive approach for total knee arthroplasty: early results of a prospective randomized study compared to a standard approach. J Arthroplasty 22:8–13PubMedCrossRef
13.
go back to reference Laskin RS, Beksac B, Phongjunakom A, Pittors K, Shim JC, Pavlov H, Petersen M (2004) Minimally invasive total knee replacement through a mini-midvastus incision; an outcome study. Clin Orthop Relat Res 428:74–81PubMedCrossRef Laskin RS, Beksac B, Phongjunakom A, Pittors K, Shim JC, Pavlov H, Petersen M (2004) Minimally invasive total knee replacement through a mini-midvastus incision; an outcome study. Clin Orthop Relat Res 428:74–81PubMedCrossRef
14.
go back to reference Lin WP, Lin J, Horng LC, Chang SM, Jiang CC (2009) Quadriceps-sparing, minimal-incision total knee arthroplasty. A comparative study. J Arthroplasty 24:1024–1032PubMedCrossRef Lin WP, Lin J, Horng LC, Chang SM, Jiang CC (2009) Quadriceps-sparing, minimal-incision total knee arthroplasty. A comparative study. J Arthroplasty 24:1024–1032PubMedCrossRef
15.
go back to reference Lombardi AV Jr, Viacava AJ, Berend KR (2006) Rapid recovery protocols and minimally invasive surgery help achieve high knee flexion. Clin Orthop Relat Res 452:117–122PubMedCrossRef Lombardi AV Jr, Viacava AJ, Berend KR (2006) Rapid recovery protocols and minimally invasive surgery help achieve high knee flexion. Clin Orthop Relat Res 452:117–122PubMedCrossRef
16.
go back to reference Luring C, Beckmann J, Haibo¨ck P, Perlick L, Grifka J, Tingart M (2008) Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomized trial. Knee Surg Sports Traumatol Arthrosc 16:928–934PubMedCrossRef Luring C, Beckmann J, Haibo¨ck P, Perlick L, Grifka J, Tingart M (2008) Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomized trial. Knee Surg Sports Traumatol Arthrosc 16:928–934PubMedCrossRef
17.
go back to reference Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilized total knee replacement. J Bone Joint Surg Br 91:475–480PubMedCrossRef Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilized total knee replacement. J Bone Joint Surg Br 91:475–480PubMedCrossRef
18.
go back to reference Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Seiji K, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Seiji K, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef
19.
go back to reference Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2010) Soft-tissue tension in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplasty (In press) Matsumoto T, Muratsu H, Kubo S, Matsushita T, Kurosaka M, Kuroda R (2010) Soft-tissue tension in cruciate-retaining and posterior-stabilized total knee arthroplasty. J Arthroplasty (In press)
20.
go back to reference Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef
21.
go back to reference Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kurosaka M, Kuroda R (2009) Soft tissue balance measurement in posterior-stabilized total knee arthroplasty with a navigation system. J Althroplasty 24:358–364CrossRef Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kurosaka M, Kuroda R (2009) Soft tissue balance measurement in posterior-stabilized total knee arthroplasty with a navigation system. J Althroplasty 24:358–364CrossRef
22.
go back to reference Niki Y, Matsumoto H, Otani T, Enomoto H, Toyama Y, Suda Y (2010) Accuracy of implant positioning for minimally invasive total knee arthroplasty in patients with severe varus deformity. J Arthroplasty 25:381–386PubMedCrossRef Niki Y, Matsumoto H, Otani T, Enomoto H, Toyama Y, Suda Y (2010) Accuracy of implant positioning for minimally invasive total knee arthroplasty in patients with severe varus deformity. J Arthroplasty 25:381–386PubMedCrossRef
23.
go back to reference Pagnano MW, Meneghini RM (2006) Minimally invasive total knee arthroplasty with an optimized subvastus approach. J Arthroplasty 21:22–26PubMedCrossRef Pagnano MW, Meneghini RM (2006) Minimally invasive total knee arthroplasty with an optimized subvastus approach. J Arthroplasty 21:22–26PubMedCrossRef
24.
go back to reference Pagnano MW, Meneghini RM, Trousdale RT (2006) Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res 452:102–105PubMedCrossRef Pagnano MW, Meneghini RM, Trousdale RT (2006) Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res 452:102–105PubMedCrossRef
25.
go back to reference Robert VI, Mereddy PKR, Donnachie NJ, Hakkalamani S (2007) Anatomical variations in vastus medialis obliquus and its implications in minimally invasive total knee replacement. J Bone Joint Surg Br 89:1462–1465CrossRef Robert VI, Mereddy PKR, Donnachie NJ, Hakkalamani S (2007) Anatomical variations in vastus medialis obliquus and its implications in minimally invasive total knee replacement. J Bone Joint Surg Br 89:1462–1465CrossRef
26.
go back to reference Schroer WC, Diesfeld PJ, Reedy ME, Lemarr AR (2010) Isokinetic strength testing of minimally invasive total knee arthroplasty recovery. J Arthroplasty 25:274–279PubMedCrossRef Schroer WC, Diesfeld PJ, Reedy ME, Lemarr AR (2010) Isokinetic strength testing of minimally invasive total knee arthroplasty recovery. J Arthroplasty 25:274–279PubMedCrossRef
27.
go back to reference Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
28.
go back to reference Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84(suppl 2):90–98PubMed Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84(suppl 2):90–98PubMed
29.
go back to reference Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2007) Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci 12:149–153PubMedCrossRef Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2007) Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci 12:149–153PubMedCrossRef
30.
go back to reference Tria AJ Jr (2003) Advancements in minimally invasive total knee arthroplasty. Orthopedics 26:s859PubMed Tria AJ Jr (2003) Advancements in minimally invasive total knee arthroplasty. Orthopedics 26:s859PubMed
31.
go back to reference Tria AJ Jr, Coon TM (2003) Minimal incision total knee arthroplasty: early experience. Clin Orthop Relat Res 416:185–190PubMedCrossRef Tria AJ Jr, Coon TM (2003) Minimal incision total knee arthroplasty: early experience. Clin Orthop Relat Res 416:185–190PubMedCrossRef
32.
go back to reference Whiteside LA, Kasselt MR, Haynes DW (1987) Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty. Clin Orthop Relat Res 219:147–157PubMed Whiteside LA, Kasselt MR, Haynes DW (1987) Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty. Clin Orthop Relat Res 219:147–157PubMed
33.
go back to reference Windsor RE, Scuderi GR, Moran MC, Insall JN (1989) Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res 248:15–19PubMed Windsor RE, Scuderi GR, Moran MC, Insall JN (1989) Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res 248:15–19PubMed
34.
go back to reference Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches. J Bone Joint Surg Br 90:520–526PubMedCrossRef Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches. J Bone Joint Surg Br 90:520–526PubMedCrossRef
Metadata
Title
Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty
Authors
Tomoyuki Matsumoto
Hirotsugu Muratsu
Seiji Kubo
Kiyonori Mizuno
Keisuke Kinoshita
Kazunari Ishida
Takehiko Matsushita
Ken Sasaki
Katsumasa Tei
Koji Takayama
Hiroshi Sasaki
Shinya Oka
Masahiro Kurosaka
Ryosuke Kuroda
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1224-z

Other articles of this Issue 6/2011

Knee Surgery, Sports Traumatology, Arthroscopy 6/2011 Go to the issue