Skip to main content
Top
Published in: Annals of Intensive Care 1/2011

Open Access 01-12-2011 | Research

Sleep quality in mechanically ventilated patients: comparison between NAVA and PSV modes

Authors: Stéphane Delisle, Paul Ouellet, Patrick Bellemare, Jean-Pierre Tétrault, Pierre Arsenault

Published in: Annals of Intensive Care | Issue 1/2011

Login to get access

Abstract

Background

Mechanical ventilation seems to occupy a major source in alteration in the quality and quantity of sleep among patients in intensive care. Quality of sleep is negatively affected with frequent patient-ventilator asynchronies and more specifically with modes of ventilation. The quality of sleep among ventilated patients seems to be related in part to the alteration between the capacities of the ventilator to meet patient demand. The objective of this study was to compare the impact of two modes of ventilation and patient-ventilator interaction on sleep architecture.

Methods

Prospective, comparative crossover study in 14 conscious, nonsedated, mechanically ventilated adults, during weaning in a university hospital medical intensive care unit. Patients were successively ventilated in a random ordered cross-over sequence with neurally adjusted ventilatory assist (NAVA) and pressure support ventilation (PSV). Sleep polysomnography was performed during four 4-hour periods, two with each mode in random order.

Results

The tracings of the flow, airway pressure, and electrical activity of the diaphragm were used to diagnose central apneas and ineffective efforts. The main abnormalities were a low percentage of rapid eye movement (REM) sleep, for a median (25th-75th percentiles) of 11.5% (range, 8-20%) of total sleep, and a highly fragmented sleep with 25 arousals and awakenings per hour of sleep. Proportions of REM sleep duration were different in the two ventilatory modes (4.5% (range, 3-11%) in PSV and 16.5% (range, 13-29%) during NAVA (p = 0.001)), as well as the fragmentation index, with 40 ± 20 arousals and awakenings per hour in PSV and 16 ± 9 during NAVA (p = 0.001). There were large differences in ineffective efforts (24 ± 23 per hour of sleep in PSV, and 0 during NAVA) and episodes of central apnea (10.5 ± 11 in PSV vs. 0 during NAVA). Minute ventilation was similar in both modes.

Conclusions

NAVA improves the quality of sleep over PSV in terms of REM sleep, fragmentation index, and ineffective efforts in a nonsedated adult population.
Appendix
Available only for authorised users
Literature
1.
go back to reference Drouot X, Cabello B, d'Ortho MP, et al.: Sleep in the intensive care unit. Sleep Med Rev 2008, 12: 391–403. 10.1016/j.smrv.2007.11.004PubMedCrossRef Drouot X, Cabello B, d'Ortho MP, et al.: Sleep in the intensive care unit. Sleep Med Rev 2008, 12: 391–403. 10.1016/j.smrv.2007.11.004PubMedCrossRef
2.
go back to reference Friese RS: Sleep and recovery from illness and injury: a review of theory, current practice, and future directions. Crit Care Med 2008, 36: 697–705. 10.1097/CCM.0B013E3181643F29PubMedCrossRef Friese RS: Sleep and recovery from illness and injury: a review of theory, current practice, and future directions. Crit Care Med 2008, 36: 697–705. 10.1097/CCM.0B013E3181643F29PubMedCrossRef
3.
go back to reference Gabor JY, Cooper AB, Crombach SA, et al.: Contribution of the Intensive Care Unit Environment to sleep disruption in mechanically ventilated patients and healthy subjects. Am J Respir Crit Care Med 2003, 167: 708–715. 10.1164/rccm.2201090PubMedCrossRef Gabor JY, Cooper AB, Crombach SA, et al.: Contribution of the Intensive Care Unit Environment to sleep disruption in mechanically ventilated patients and healthy subjects. Am J Respir Crit Care Med 2003, 167: 708–715. 10.1164/rccm.2201090PubMedCrossRef
4.
go back to reference Bryant PA, Trinde J, Curtis N: Sick and tired: Does sleep have a vital role in the immune system? Nat Rev Immunol 2004, 4: 457–467. 10.1038/nri1369PubMedCrossRef Bryant PA, Trinde J, Curtis N: Sick and tired: Does sleep have a vital role in the immune system? Nat Rev Immunol 2004, 4: 457–467. 10.1038/nri1369PubMedCrossRef
5.
go back to reference Valente M, Placidi F, Oliveira AJ, et al.: Sleep organization pattern as a prognostic marker at the subacute stage of posttraumatic coma. Clin Neurophysiol 2002, 113: 1798–1805. 10.1016/S1388-2457(02)00218-3PubMedCrossRef Valente M, Placidi F, Oliveira AJ, et al.: Sleep organization pattern as a prognostic marker at the subacute stage of posttraumatic coma. Clin Neurophysiol 2002, 113: 1798–1805. 10.1016/S1388-2457(02)00218-3PubMedCrossRef
6.
go back to reference Helton MC, Gordon SH, Nunnery SL: The correlation between sleep deprivation and the intensive care unit syndrome. Heart Lung 1980, 9: 464–468.PubMed Helton MC, Gordon SH, Nunnery SL: The correlation between sleep deprivation and the intensive care unit syndrome. Heart Lung 1980, 9: 464–468.PubMed
7.
go back to reference Chen HI, Tang YR: Sleep loss impairs inspiratory muscle endurance. Am Rev Respir Dis 1989, 140: 907–909.PubMedCrossRef Chen HI, Tang YR: Sleep loss impairs inspiratory muscle endurance. Am Rev Respir Dis 1989, 140: 907–909.PubMedCrossRef
8.
go back to reference Andrews P, Azoulay E, Antonelli M, et al.: Year in review in intensive care medicine 2004. Part I. Respiratory failure, infection and sepsis. Intensive Care Med 2005, 31: 28–40. 10.1007/s00134-004-2529-5PubMedCrossRef Andrews P, Azoulay E, Antonelli M, et al.: Year in review in intensive care medicine 2004. Part I. Respiratory failure, infection and sepsis. Intensive Care Med 2005, 31: 28–40. 10.1007/s00134-004-2529-5PubMedCrossRef
9.
go back to reference Andrews P, Azoulay E, Antonelli M, et al.: Year in review in intensive care medicine 2005. Part II. Acute respiratory failure and acute lung injury, ventilation, hemodynamics, education renal failure. Intensive Care Med 2006, 32: 207–216. 10.1007/s00134-005-0027-zPubMedCrossRef Andrews P, Azoulay E, Antonelli M, et al.: Year in review in intensive care medicine 2005. Part II. Acute respiratory failure and acute lung injury, ventilation, hemodynamics, education renal failure. Intensive Care Med 2006, 32: 207–216. 10.1007/s00134-005-0027-zPubMedCrossRef
10.
go back to reference Aaron JN, Carlisle CC, Carskadon MA, et al.: Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit. Sleep 1996, 19: 707–710.PubMed Aaron JN, Carlisle CC, Carskadon MA, et al.: Environmental noise as a cause of sleep disruption in an intermediate respiratory care unit. Sleep 1996, 19: 707–710.PubMed
11.
go back to reference Freedman NS, Gazendam J, Levan L, et al.: Abnormal sleep/wake cycles and the effect of environmental noise on sleep disruption in the intensive care unit. Am J Respir Med 2001, 163: 451–457.CrossRef Freedman NS, Gazendam J, Levan L, et al.: Abnormal sleep/wake cycles and the effect of environmental noise on sleep disruption in the intensive care unit. Am J Respir Med 2001, 163: 451–457.CrossRef
12.
go back to reference Hilton BA: Quantity and quality of patients' sleep and sleep-disturbing factors in a respiratory intensive care unit. J Adv Nurs 1976, 1: 453–468. 10.1111/j.1365-2648.1976.tb00932.xPubMedCrossRef Hilton BA: Quantity and quality of patients' sleep and sleep-disturbing factors in a respiratory intensive care unit. J Adv Nurs 1976, 1: 453–468. 10.1111/j.1365-2648.1976.tb00932.xPubMedCrossRef
13.
go back to reference Cooper AB, Thornley KS, Young GB, et al.: Sleep in critically ill patients requiring mechanical ventilation. Chest 2000, 117: 809–818. 10.1378/chest.117.3.809PubMedCrossRef Cooper AB, Thornley KS, Young GB, et al.: Sleep in critically ill patients requiring mechanical ventilation. Chest 2000, 117: 809–818. 10.1378/chest.117.3.809PubMedCrossRef
14.
go back to reference Freedman NS, Kotzer N, Schwab RJ: Patient perception of sleep quality and etiology of sleep disruption in the intensive care unit. Am J Respir Crit Care Med 1990, 159: 1155–1162.CrossRef Freedman NS, Kotzer N, Schwab RJ: Patient perception of sleep quality and etiology of sleep disruption in the intensive care unit. Am J Respir Crit Care Med 1990, 159: 1155–1162.CrossRef
15.
go back to reference Parthasarathy S, Tobin MJ: Effect of ventilator mode on sleep quality in critically ill patients. Am J Respir Crit Care Med 2002, 166: 1423–1429. 10.1164/rccm.200209-999OCPubMedCrossRef Parthasarathy S, Tobin MJ: Effect of ventilator mode on sleep quality in critically ill patients. Am J Respir Crit Care Med 2002, 166: 1423–1429. 10.1164/rccm.200209-999OCPubMedCrossRef
16.
go back to reference Nakayama H, Smith CA, Rodman JR, et al.: Effect of ventilatory drive on carbon dioxide sensitivity below eupnea during sleep. Am J Respir Crit Care Med 2002, 165: 1251–1260. 10.1164/rccm.2110041PubMedCrossRef Nakayama H, Smith CA, Rodman JR, et al.: Effect of ventilatory drive on carbon dioxide sensitivity below eupnea during sleep. Am J Respir Crit Care Med 2002, 165: 1251–1260. 10.1164/rccm.2110041PubMedCrossRef
17.
go back to reference Thille AW, Rodriguez P, Cabello B, et al.: Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 2006, 32: 1515–1522. 10.1007/s00134-006-0301-8PubMedCrossRef Thille AW, Rodriguez P, Cabello B, et al.: Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 2006, 32: 1515–1522. 10.1007/s00134-006-0301-8PubMedCrossRef
18.
go back to reference Fanfulla F, Delmastro M, Berardinelli A, et al.: Effects of different ventilator settings on sleep and inspiratory effort in patients with neuromuscular disease. Am J Respir Crit Care Med 2005, 172: 619–624. 10.1164/rccm.200406-694OCPubMedCrossRef Fanfulla F, Delmastro M, Berardinelli A, et al.: Effects of different ventilator settings on sleep and inspiratory effort in patients with neuromuscular disease. Am J Respir Crit Care Med 2005, 172: 619–624. 10.1164/rccm.200406-694OCPubMedCrossRef
19.
go back to reference Cabello B, Thille AW, Drouot X, et al.: Sleep quality in mechanically ventilated patients: comparison of three ventilatory modes. Crit Care Med 2008, 36: 1749–1755. 10.1097/CCM.0b013e3181743f41PubMedCrossRef Cabello B, Thille AW, Drouot X, et al.: Sleep quality in mechanically ventilated patients: comparison of three ventilatory modes. Crit Care Med 2008, 36: 1749–1755. 10.1097/CCM.0b013e3181743f41PubMedCrossRef
20.
go back to reference Jasper HH: The ten twenty electrode system of the International Federation. Electroencephal Clin Neurophysiol 1958, 10: 371–375. Jasper HH: The ten twenty electrode system of the International Federation. Electroencephal Clin Neurophysiol 1958, 10: 371–375.
21.
go back to reference Rechtschaffen A, Kales A: A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. Los Angeles, UCLA BIS/BRI; 1968. Rechtschaffen A, Kales A: A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. Los Angeles, UCLA BIS/BRI; 1968.
22.
go back to reference Iber C, Ancoli-Israel S, Chesson A, et al.: The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, 1st ed. Westchester, Illinois. American Academy of Sleep Medicine; 2007. Iber C, Ancoli-Israel S, Chesson A, et al.: The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, 1st ed. Westchester, Illinois. American Academy of Sleep Medicine; 2007.
23.
go back to reference EEG arousals, Scoring rules and examples: A preliminary report from the Sleep Disorders Atlas Task Force of the American Sleep Disorders Association. Sleep 1992, 15: 173–184. EEG arousals, Scoring rules and examples: A preliminary report from the Sleep Disorders Atlas Task Force of the American Sleep Disorders Association. Sleep 1992, 15: 173–184.
24.
go back to reference Force TRoaAAoSMT: Sleep-related breathing disorders in adults: Recommendation for syndrome definition and measurement techniques in clinical research. Sleep 1999, 22: 667–689. Force TRoaAAoSMT: Sleep-related breathing disorders in adults: Recommendation for syndrome definition and measurement techniques in clinical research. Sleep 1999, 22: 667–689.
25.
go back to reference Xie A, Wong B, Phillipson EA, et al.: Interaction of hyperventilation and arousal in the pathogenesis of idiopathic central sleep apnea. Am J respire Crit Care Med 1994, 150: 489–495.CrossRef Xie A, Wong B, Phillipson EA, et al.: Interaction of hyperventilation and arousal in the pathogenesis of idiopathic central sleep apnea. Am J respire Crit Care Med 1994, 150: 489–495.CrossRef
26.
go back to reference Trinder J, Merson R, Rosenberg JI, et al.: Pathophysiological interactions of ventilation, arousals, and blood pressure oscillations during Cheyne-Stokes respiration in patients with heart failure. Am J Respir Crit Care Med 2000, 162: 808–813.PubMedCrossRef Trinder J, Merson R, Rosenberg JI, et al.: Pathophysiological interactions of ventilation, arousals, and blood pressure oscillations during Cheyne-Stokes respiration in patients with heart failure. Am J Respir Crit Care Med 2000, 162: 808–813.PubMedCrossRef
27.
go back to reference Toublanc B, Rose D, Glerant JC, et al.: Assist-control ventilation vs. low levels of pressure support ventilation on sleep quality in intubated ICU patients. Intensive Care Med 2007, 33: 1148–1154. 10.1007/s00134-007-0659-2PubMedCrossRef Toublanc B, Rose D, Glerant JC, et al.: Assist-control ventilation vs. low levels of pressure support ventilation on sleep quality in intubated ICU patients. Intensive Care Med 2007, 33: 1148–1154. 10.1007/s00134-007-0659-2PubMedCrossRef
28.
go back to reference Brochard L, Pluskwa F, Lemaire F: Improved efficacy of spontaneous breathing with inspiratory pressure support. Am Respir Dis 1987, 136: 411–415. 10.1164/ajrccm/136.2.411CrossRef Brochard L, Pluskwa F, Lemaire F: Improved efficacy of spontaneous breathing with inspiratory pressure support. Am Respir Dis 1987, 136: 411–415. 10.1164/ajrccm/136.2.411CrossRef
29.
go back to reference Leleu O, Mayeux I, Journieaux V: Effets de l'adjonction d'une aide inspiratoire de 6 cmH2O sur la consummation en oxygène des muscles respiratoires au cours du sevrage de la ventilation mécanique. Rev Mal Respir 2001, 18: 283–288.PubMed Leleu O, Mayeux I, Journieaux V: Effets de l'adjonction d'une aide inspiratoire de 6 cmH2O sur la consummation en oxygène des muscles respiratoires au cours du sevrage de la ventilation mécanique. Rev Mal Respir 2001, 18: 283–288.PubMed
30.
go back to reference Tassaux D, Gainnier M, Battisti A, et al.: Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. Am J Respir Crit Care Med 2005, 172: 1283–1289. 10.1164/rccm.200407-880OCPubMedCrossRef Tassaux D, Gainnier M, Battisti A, et al.: Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. Am J Respir Crit Care Med 2005, 172: 1283–1289. 10.1164/rccm.200407-880OCPubMedCrossRef
31.
go back to reference Bosma K, Ferreyra G, Ambrogio C, et al.: Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation. Crit Care Med 2007, 35: 1048–1054. 10.1097/01.CCM.0000260055.64235.7CPubMedCrossRef Bosma K, Ferreyra G, Ambrogio C, et al.: Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation. Crit Care Med 2007, 35: 1048–1054. 10.1097/01.CCM.0000260055.64235.7CPubMedCrossRef
32.
go back to reference Thille AW, Rodriguez P, Cabello B, et al.: Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 2006, 32: 1515–1522. 10.1007/s00134-006-0301-8PubMedCrossRef Thille AW, Rodriguez P, Cabello B, et al.: Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 2006, 32: 1515–1522. 10.1007/s00134-006-0301-8PubMedCrossRef
33.
go back to reference Schmidt M, Demoule A, Crasso C, et al.: Neurally adjusted ventilatory assist increases respiratory variability and complexity in acute respiratory failure. Anesthesiology 2010, 112: 670–681. 10.1097/ALN.0b013e3181cea375PubMedCrossRef Schmidt M, Demoule A, Crasso C, et al.: Neurally adjusted ventilatory assist increases respiratory variability and complexity in acute respiratory failure. Anesthesiology 2010, 112: 670–681. 10.1097/ALN.0b013e3181cea375PubMedCrossRef
34.
go back to reference Issa FG, Sullivan CE: Arousal and breathing responses to airway occlusion in healthy sleeping adults. J Appl Physiol 1983, 55: 1113–1119.PubMed Issa FG, Sullivan CE: Arousal and breathing responses to airway occlusion in healthy sleeping adults. J Appl Physiol 1983, 55: 1113–1119.PubMed
Metadata
Title
Sleep quality in mechanically ventilated patients: comparison between NAVA and PSV modes
Authors
Stéphane Delisle
Paul Ouellet
Patrick Bellemare
Jean-Pierre Tétrault
Pierre Arsenault
Publication date
01-12-2011
Publisher
Springer Paris
Published in
Annals of Intensive Care / Issue 1/2011
Electronic ISSN: 2110-5820
DOI
https://doi.org/10.1186/2110-5820-1-42

Other articles of this Issue 1/2011

Annals of Intensive Care 1/2011 Go to the issue