Skip to main content
Top
Published in: Molecular Imaging and Biology 3/2011

01-06-2011 | Research Article

Simultaneous Dual-tracer PET Imaging of the Rat Brain and its Application in the Study of Cerebral Ischemia

Authors: Francisca P. Figueiras, Xavier Jiménez, Deborah Pareto, Vanessa Gómez, Jordi Llop, Raul Herance, Santiago Rojas, Juan D. Gispert

Published in: Molecular Imaging and Biology | Issue 3/2011

Login to get access

Abstract

Purpose

This study evaluates the performance of simultaneous dual-tracer technique (SDTT) in static positron emission tomography (PET) studies using 2-deoxy-2-[18F]fluoro-D-glucose and [13N]ammonium as radiotracers.

Procedures

The effects of applying SDTT either to the reconstructed image or directly to the sinogram, different rebinning algorithms, total acquisition time, and frame duration were investigated; first, using a specific phantom and later using an in vivo application of the study of cerebral ischemia.

Results

The best results were obtained using the image method with single-slice rebinning and a total acquisition time of at least 20 min. Frame duration did not affect SDTT performance. The method was also applied in rats with transient cerebral ischemia to simultaneously study cerebral blood flow and cerebral glucose metabolism.

Conclusion

The results encourage the use of SDTT as it has very good potential for examining two different biological processes at the same time utilising rodent PET scanners.
Literature
1.
go back to reference Kiat H, Germano G, Friedman J, Van Train K, Silagan G, Wang FP, Maddahi J, Berman D (1994) Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med 35(4):542–548PubMed Kiat H, Germano G, Friedman J, Van Train K, Silagan G, Wang FP, Maddahi J, Berman D (1994) Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med 35(4):542–548PubMed
2.
go back to reference Unlu M, Gunaydin S, Ilgin N, Inanir S, Gokcora N, Gokgoz L (1993) Dual isotope myocardial perfusion SPECT in the detection of coronary artery disease: comparison of separate and simultaneous acquisition protocols. J Nucl Biol Med 37(4):233–237PubMed Unlu M, Gunaydin S, Ilgin N, Inanir S, Gokcora N, Gokgoz L (1993) Dual isotope myocardial perfusion SPECT in the detection of coronary artery disease: comparison of separate and simultaneous acquisition protocols. J Nucl Biol Med 37(4):233–237PubMed
3.
go back to reference Wu YW, Huang PJ, Lee CM, Ho YL, Lin LC, Wang TD, Wang SS, Chen TH, Yen RF (2005) Assessment of myocardial viability using F-18 fluorodeoxyglucose/Tc-99m sestamibi dual-isotope simultaneous acquisition SPECT: comparison with Tl-201 stress-reinjection SPECT. J Nucl Cardiol 12(4):451–459PubMedCrossRef Wu YW, Huang PJ, Lee CM, Ho YL, Lin LC, Wang TD, Wang SS, Chen TH, Yen RF (2005) Assessment of myocardial viability using F-18 fluorodeoxyglucose/Tc-99m sestamibi dual-isotope simultaneous acquisition SPECT: comparison with Tl-201 stress-reinjection SPECT. J Nucl Cardiol 12(4):451–459PubMedCrossRef
4.
go back to reference Huang SC, Carson RE, Hoffman EJ, Kuhl DE, Phelps ME (1982) An investigation of a double-tracer technique for positron computerized tomography. J Nucl Med 23(9):816–822PubMed Huang SC, Carson RE, Hoffman EJ, Kuhl DE, Phelps ME (1982) An investigation of a double-tracer technique for positron computerized tomography. J Nucl Med 23(9):816–822PubMed
5.
go back to reference Verhaeghe J, D'Asseler Y, Staelens S, Lemahieu I (2005) Noise properties of simultaneous dual tracer PET imaging. IEEE Nuclear Science Symposium, San Juan Verhaeghe J, D'Asseler Y, Staelens S, Lemahieu I (2005) Noise properties of simultaneous dual tracer PET imaging. IEEE Nuclear Science Symposium, San Juan
6.
go back to reference Black NF, McJames S, Rust TC, Kadrmas DJ (2008) Evaluation of rapid dual-tracer (62)Cu-PTSM + (62)Cu-ATSM PET in dogs with spontaneously occurring tumors. Phys Med Biol 53(1):217–232PubMedCrossRef Black NF, McJames S, Rust TC, Kadrmas DJ (2008) Evaluation of rapid dual-tracer (62)Cu-PTSM + (62)Cu-ATSM PET in dogs with spontaneously occurring tumors. Phys Med Biol 53(1):217–232PubMedCrossRef
7.
go back to reference Ikoma Y, Toyama H, Suhara T (2004) Simultaneous quantification of two brain functions with dual tracer injection in PET dynamic study. In: Iida H, Shah NJ, Hayashi T, Watabe H (eds) Quantitation in biomedical imaging with PET and MRI. Quantitation in PET and image processing, 1st edn. Elsevier, Amsterdam, The Netherlands, pp 74–78 Ikoma Y, Toyama H, Suhara T (2004) Simultaneous quantification of two brain functions with dual tracer injection in PET dynamic study. In: Iida H, Shah NJ, Hayashi T, Watabe H (eds) Quantitation in biomedical imaging with PET and MRI. Quantitation in PET and image processing, 1st edn. Elsevier, Amsterdam, The Netherlands, pp 74–78
8.
go back to reference Rust TC, Kadrmas DJ (2006) Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study. Phys Med Biol 51(1):61–75PubMedCrossRef Rust TC, Kadrmas DJ (2006) Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study. Phys Med Biol 51(1):61–75PubMedCrossRef
9.
go back to reference Wilson JW, Turkington TG, Colsher JG, Borges-Neto S, Reinman RE, Coleman E (2004) Optimizing sequencial dual tracer PET studies using combined 2D/3D Imaging Protocol. in IEEE Nuclear Science Symposium. Rome (Italy) Wilson JW, Turkington TG, Colsher JG, Borges-Neto S, Reinman RE, Coleman E (2004) Optimizing sequencial dual tracer PET studies using combined 2D/3D Imaging Protocol. in IEEE Nuclear Science Symposium. Rome (Italy)
10.
go back to reference Martín A, Rojas S, Pareto D, Santalucia T, Millán O, Abasolo I, Gómez V, Llop J, Gispert JD, Falcon C, Bargalló N, Planas AM (2008) Depressed glucose consumption at reperfusion following brain ischemia does not correlate with mitochondrial dysfunction and development of infarction: an in vivo positron emission tomography study. Curr Neurovasc Res 6(2):82–88CrossRef Martín A, Rojas S, Pareto D, Santalucia T, Millán O, Abasolo I, Gómez V, Llop J, Gispert JD, Falcon C, Bargalló N, Planas AM (2008) Depressed glucose consumption at reperfusion following brain ischemia does not correlate with mitochondrial dysfunction and development of infarction: an in vivo positron emission tomography study. Curr Neurovasc Res 6(2):82–88CrossRef
11.
go back to reference Daube-Witherspoon ME, Muehllehner G (1987) Treatment of axial data in three-dimensional PET. J Nucl Med 28(11):1717–1724PubMed Daube-Witherspoon ME, Muehllehner G (1987) Treatment of axial data in three-dimensional PET. J Nucl Med 28(11):1717–1724PubMed
12.
go back to reference Defrise M, Kinahan PE, Townsend DW, Michel C, Sibomana M, Newport DF (1997) Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging 16(2):145–158PubMedCrossRef Defrise M, Kinahan PE, Townsend DW, Michel C, Sibomana M, Newport DF (1997) Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imaging 16(2):145–158PubMedCrossRef
13.
go back to reference Martin A, Rojas S, Chamorro A, Falcon C, Bargallo N, Planas AM (2006) Why does acute hyperglycemia worsen the outcome of transient focal cerebral ischemia? Role of corticosteroids, inflammation, and protein O-glycosylation. Stroke 37(5):1288–1295PubMedCrossRef Martin A, Rojas S, Chamorro A, Falcon C, Bargallo N, Planas AM (2006) Why does acute hyperglycemia worsen the outcome of transient focal cerebral ischemia? Role of corticosteroids, inflammation, and protein O-glycosylation. Stroke 37(5):1288–1295PubMedCrossRef
14.
go back to reference Bouallegue FB, Crouzet JF, Comtat C, Fourcade M, Mohammadi B, Mariano-Goulart D (2007) Exact and approximate Fourier rebinning algorithms for the solution of the data truncation problem in 3-D PET. IEEE Trans Med Imaging 26(7):1001–1009PubMedCrossRef Bouallegue FB, Crouzet JF, Comtat C, Fourcade M, Mohammadi B, Mariano-Goulart D (2007) Exact and approximate Fourier rebinning algorithms for the solution of the data truncation problem in 3-D PET. IEEE Trans Med Imaging 26(7):1001–1009PubMedCrossRef
15.
go back to reference Valk PE, Dale L, Bailey D, Townsend DW, Maisey MN (2004) Positron emission tomography: basic science and clinical practice. Springer, London Valk PE, Dale L, Bailey D, Townsend DW, Maisey MN (2004) Positron emission tomography: basic science and clinical practice. Springer, London
16.
go back to reference Vaquero JJ, Desco M (2005) Technical limitations of the positron emission tomography (PET) for small laboratory animals. Rev Esp Med Nucl 24(5):334–347PubMedCrossRef Vaquero JJ, Desco M (2005) Technical limitations of the positron emission tomography (PET) for small laboratory animals. Rev Esp Med Nucl 24(5):334–347PubMedCrossRef
17.
go back to reference Jagoda EM, Vaquero JJ, Seidel J, Green MV, Eckelman WC (2004) Experiment assessment of mass effects in the rat: implications for small animal PET imaging. Nucl Med Biol 31(6):771–779PubMedCrossRef Jagoda EM, Vaquero JJ, Seidel J, Green MV, Eckelman WC (2004) Experiment assessment of mass effects in the rat: implications for small animal PET imaging. Nucl Med Biol 31(6):771–779PubMedCrossRef
18.
go back to reference trother SC, Casey ME, Hoffman EJ (1990) Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using Noise Equivalent Counts, in IEEE T Nucl Sci trother SC, Casey ME, Hoffman EJ (1990) Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using Noise Equivalent Counts, in IEEE T Nucl Sci
Metadata
Title
Simultaneous Dual-tracer PET Imaging of the Rat Brain and its Application in the Study of Cerebral Ischemia
Authors
Francisca P. Figueiras
Xavier Jiménez
Deborah Pareto
Vanessa Gómez
Jordi Llop
Raul Herance
Santiago Rojas
Juan D. Gispert
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Molecular Imaging and Biology / Issue 3/2011
Print ISSN: 1536-1632
Electronic ISSN: 1860-2002
DOI
https://doi.org/10.1007/s11307-010-0370-5

Other articles of this Issue 3/2011

Molecular Imaging and Biology 3/2011 Go to the issue