01-05-2021 | Silicone | Original Research

Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study

Authors: Edwin Seet, Jinbin Zhang, Joselo Macachor, Chandra M. Kumar

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2021

Login to get access

Abstract

General anaesthesia is sometimes favoured over regional anaesthesia in ophthalmic surgery. The use of supraglottic airway (SGA) or laryngeal mask airway (LMA) as the primary airway device is increasing due to numerous advantages over tracheal intubation. Compared with 1st generation SGAs, 2nd generation SGAs have an added benefit of isolating the airway from the alimentary tract. However, the vertical profile of SGAs may encroach into the surgical field and hence interfere with surgery. We investigated the vertical projections of 1st generation SGAs (LMA Classic, Ambu AuraFlex) and commonly used 2nd generation SGAs in our institution (LMA ProSeal, LMA Supreme, LMA Protector, Ambu AuraGain and I-gel) in a manikin model. Each device was connected to a corrugated catheter mount or angled connector following insertion as per usual clinical practice in our institutions. Vertical projections of all devices were measured from the chin using a centimetre ruler. Securing of airway device to the chin with an adhesive tape was possible for the LMA Classic and Ambu AuraFlex with straight corrugated connector, whereas the stiffer 2nd generations SGAs required the addition of an angled connector or straight corrugated tubing to direct the airway tube caudally, away from the surgical field. The LMA ProSeal had the lowest vertical projection amongst the 2nd generation SGAs and may be the suitable choice for ophthalmic surgery. We also describe a novel technique of utilising a 1st generation SGA with placement of an orogastric tube, although with some reservations. This study has several limitations and transferability of our findings into clinical practice is questionable as the use of a manikin may not fully imitate the real condition of the patient. Our study is the first study comparing vertical projected height of different SGAs in manikin, but future studies should investigate the use of SGA in the clinical setting during ophthalmic surgery.
Literature
1.
go back to reference Kumar CM, Eke T, Dodds C, Deane JS, El-Hindy N, Johnston RL, et al. Local anaesthesia for ophthalmic surgery—new guidelines from the Royal College of Anaesthetists and the Royal College of Ophthalmologists. Eye (Lond). 2012;26:897–8.CrossRef Kumar CM, Eke T, Dodds C, Deane JS, El-Hindy N, Johnston RL, et al. Local anaesthesia for ophthalmic surgery—new guidelines from the Royal College of Anaesthetists and the Royal College of Ophthalmologists. Eye (Lond). 2012;26:897–8.CrossRef
2.
go back to reference Kelly DJ, Farrell SM. Physiology and role of intraocular pressure in contemporary anesthesia. Anesth Analg. 2018;126:1551–62.CrossRef Kelly DJ, Farrell SM. Physiology and role of intraocular pressure in contemporary anesthesia. Anesth Analg. 2018;126:1551–62.CrossRef
3.
go back to reference Brimacombe J. The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. Can J Anaesth. 1995;42:1017–23.CrossRef Brimacombe J. The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. Can J Anaesth. 1995;42:1017–23.CrossRef
4.
go back to reference Yu SH, Beirne OR. Laryngeal mask airways have a lower risk of airway complications compared with endotracheal intubation: a systematic review. J Oral Maxillofac Surg. 2010;68:2359–76.CrossRef Yu SH, Beirne OR. Laryngeal mask airways have a lower risk of airway complications compared with endotracheal intubation: a systematic review. J Oral Maxillofac Surg. 2010;68:2359–76.CrossRef
5.
go back to reference Holloway KB. Control of the eye during general anaesthesia for intraocular surgery. Br J Anaesth. 1980;52:671–9.CrossRef Holloway KB. Control of the eye during general anaesthesia for intraocular surgery. Br J Anaesth. 1980;52:671–9.CrossRef
6.
go back to reference Joshi GP, Inagaki Y, White PF, Taylor-Kennedy L, Wat LI, Gevirtz C, et al. Use of the laryngeal mask airway as an alternative to the tracheal tube during ambulatory anesthesia. Anesth Analg. 1997;85:573–7.CrossRef Joshi GP, Inagaki Y, White PF, Taylor-Kennedy L, Wat LI, Gevirtz C, et al. Use of the laryngeal mask airway as an alternative to the tracheal tube during ambulatory anesthesia. Anesth Analg. 1997;85:573–7.CrossRef
7.
go back to reference Qamarul Hoda M, Samad K, Ullah H. ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery. Cochrane Database Syst Rev. 2017;7:CD009026.PubMed Qamarul Hoda M, Samad K, Ullah H. ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery. Cochrane Database Syst Rev. 2017;7:CD009026.PubMed
8.
go back to reference Timmermann A, Bergner UA, Russo SG. Laryngeal mask airway indications: new frontiers for second-generation supraglottic airways. Curr Opin Anaesthesiol. 2015;28:717–26.CrossRef Timmermann A, Bergner UA, Russo SG. Laryngeal mask airway indications: new frontiers for second-generation supraglottic airways. Curr Opin Anaesthesiol. 2015;28:717–26.CrossRef
9.
go back to reference Frerk C, Mitchell VS, McNarry AF, Mendonca C, Bhagrath R, Patel A, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827–48.CrossRef Frerk C, Mitchell VS, McNarry AF, Mendonca C, Bhagrath R, Patel A, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827–48.CrossRef
Metadata
Title
Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
Authors
Edwin Seet
Jinbin Zhang
Joselo Macachor
Chandra M. Kumar
Publication date
01-05-2021
Publisher
Springer Netherlands
Keyword
Silicone
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2021
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00507-w

Other articles of this Issue 3/2021

Journal of Clinical Monitoring and Computing 3/2021 Go to the issue