Skip to main content
Top
Published in: Hernia 2/2011

01-04-2011 | Original Article

Searching for the best polypropylene mesh to be used in bowel contamination

Authors: A. Díaz-Godoy, M. Á. García-Ureña, J. López-Monclús, V. Vega Ruíz, D. Melero Montes, N. Erquinigo Agurto

Published in: Hernia | Issue 2/2011

Login to get access

Abstract

Purpose

There is still some concern about the use of polypropylene in case of infection or contamination. The biocompatibility of the recently introduced light-weight polypropylene meshes seems to be promising. This experimental study was designed to evaluate three different weights and pore sizes of polypropylene meshes in a contamination model.

Methods

Thirty rabbits were operated through a pararectal incision. The abdomen, wound and mesh were contaminated with faecal fluid aspirated from the appendix. Groups of ten animals were studied according to three different pore sizes of polypropylene mesh implanted as an inlay technique: very large pore, large pore and medium pore. Five animals of each group were sacrificed on days 21 and 90. Incisional surgical site infection and microbiologic cultures on the 21st and 90th days were the main outcome measures. Tissue integration, shrinkage and biomechanical properties were also tested.

Results

Two rabbits died on day 1. There were six incisional surgical site infections (21.4%). Four animals had positive cultures with no macroscopic infection. None of the surviving rabbits with very large pore mesh had clinical infection or positive microbiologic cultures. Very large pore meshes shrank significantly more on day 21. There were no differences in the tensiometric test results.

Conclusions

In our experimental model, low-weight, very large pore polypropylene meshes seem to be the best polypropylene mesh in case of intestinal contamination. These results encourage clinical investigation on the use of low-weight, very large pore polypropylene meshes in the treatment and prevention of hernias in the presence of clean-contaminated or contaminated fields.
Appendix
Available only for authorised users
Literature
1.
go back to reference Campanelli G, Nicolosi FM, Pettinari D, Avesani EC (2004) Prosthetic repair, intestinal resection, and potentially contaminated areas: safe and feasible? Hernia 8:190–192PubMedCrossRef Campanelli G, Nicolosi FM, Pettinari D, Avesani EC (2004) Prosthetic repair, intestinal resection, and potentially contaminated areas: safe and feasible? Hernia 8:190–192PubMedCrossRef
2.
go back to reference Alaedeen DI, Lipman J, Medalie D, Rosen MJ (2007) The single-staged approach to the surgical management of abdominal wall hernias in contaminated fields. Hernia 11:41–45PubMedCrossRef Alaedeen DI, Lipman J, Medalie D, Rosen MJ (2007) The single-staged approach to the surgical management of abdominal wall hernias in contaminated fields. Hernia 11:41–45PubMedCrossRef
3.
go back to reference Engelsman AF, van Dam GM, van der Mei HC, Busscher HJ, Ploeg RJ (2010) In vivo evaluation of bacterial infection involving morphologically different surgical meshes. Ann Surg 251:133–137PubMedCrossRef Engelsman AF, van Dam GM, van der Mei HC, Busscher HJ, Ploeg RJ (2010) In vivo evaluation of bacterial infection involving morphologically different surgical meshes. Ann Surg 251:133–137PubMedCrossRef
4.
go back to reference Ott R, Hartwig T, Tannapfel A, Blatz R, Rodloff AC, Madaj-Sterba P, Möbius Ch, Köckerling F (2007) Biocompatibility of bacterial contaminated prosthetic meshes and porcine dermal collagen used to repair abdominal wall defects. Langenbecks Arch Surg 392:473–478PubMedCrossRef Ott R, Hartwig T, Tannapfel A, Blatz R, Rodloff AC, Madaj-Sterba P, Möbius Ch, Köckerling F (2007) Biocompatibility of bacterial contaminated prosthetic meshes and porcine dermal collagen used to repair abdominal wall defects. Langenbecks Arch Surg 392:473–478PubMedCrossRef
5.
go back to reference Kelly ME, Behrman SW (2002) The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds. Am Surg 68:524–528PubMed Kelly ME, Behrman SW (2002) The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds. Am Surg 68:524–528PubMed
6.
go back to reference Aydinuraz K, Ağalar C, Ağalar F, Ceken S, Duruyürek N, Vural T (2009) In vitro S. epidermidis and S. aureus adherence to composite and lightweight polypropylene grafts. J Surg Res 157:e79–e86PubMedCrossRef Aydinuraz K, Ağalar C, Ağalar F, Ceken S, Duruyürek N, Vural T (2009) In vitro S. epidermidis and S. aureus adherence to composite and lightweight polypropylene grafts. J Surg Res 157:e79–e86PubMedCrossRef
7.
go back to reference Horan TC, Gaynes RP, Martone WJ, Jarvis WR, Emori TG (1992) CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Am J Infect Control 20:271–274PubMedCrossRef Horan TC, Gaynes RP, Martone WJ, Jarvis WR, Emori TG (1992) CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Am J Infect Control 20:271–274PubMedCrossRef
8.
go back to reference Weyhe D, Schmitz I, Belyaev O, Grabs R, Müller KM, Uhl W, Zumtobel V (2006) Experimental comparison of monofile light and heavy polypropylene meshes: less weight does not mean less biological response. World J Surg 30:1586–1591PubMedCrossRef Weyhe D, Schmitz I, Belyaev O, Grabs R, Müller KM, Uhl W, Zumtobel V (2006) Experimental comparison of monofile light and heavy polypropylene meshes: less weight does not mean less biological response. World J Surg 30:1586–1591PubMedCrossRef
9.
go back to reference Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043PubMedCrossRef Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043PubMedCrossRef
10.
go back to reference Klinge U, Junge K, Stumpf M, AP AP, Klosterhalfen B (2002) Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136PubMedCrossRef Klinge U, Junge K, Stumpf M, AP AP, Klosterhalfen B (2002) Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136PubMedCrossRef
11.
go back to reference Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef
12.
go back to reference Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef
13.
go back to reference Earle DB, Mark LA (2008) Prosthetic material in inguinal hernia repair: how do I choose? Surg Clin North Am 88:179–201PubMedCrossRef Earle DB, Mark LA (2008) Prosthetic material in inguinal hernia repair: how do I choose? Surg Clin North Am 88:179–201PubMedCrossRef
14.
go back to reference Falagas ME, Kasiakou SK (2005) Mesh-related infections after hernia repair surgery. Clin Microbiol Infect 11:3–8PubMedCrossRef Falagas ME, Kasiakou SK (2005) Mesh-related infections after hernia repair surgery. Clin Microbiol Infect 11:3–8PubMedCrossRef
15.
go back to reference Strzelczyk JM, Szymański D, Nowicki ME, Wilczyński W, Gaszynski T, Czupryniak L (2006) Randomized clinical trial of postoperative hernia prophylaxis in open bariatric surgery. Br J Surg 93:1347–1350PubMedCrossRef Strzelczyk JM, Szymański D, Nowicki ME, Wilczyński W, Gaszynski T, Czupryniak L (2006) Randomized clinical trial of postoperative hernia prophylaxis in open bariatric surgery. Br J Surg 93:1347–1350PubMedCrossRef
16.
go back to reference Wysocki A, Pozniczek M, Krzywon J, Bolt L (2001) Use of polypropylene prostheses for strangulated inguinal and incisional hernias. Hernia 5:105–106PubMedCrossRef Wysocki A, Pozniczek M, Krzywon J, Bolt L (2001) Use of polypropylene prostheses for strangulated inguinal and incisional hernias. Hernia 5:105–106PubMedCrossRef
17.
go back to reference Pans A, Desaive C, Jacquet N (1997) Use of a preperitoneal prosthesis for strangulated groin hernia. Br J Surg 84:310–312PubMedCrossRef Pans A, Desaive C, Jacquet N (1997) Use of a preperitoneal prosthesis for strangulated groin hernia. Br J Surg 84:310–312PubMedCrossRef
18.
go back to reference Vix J, Meyer Ch, Rohr S, Bourtoul Ch (1997) The treatment of incisional and abdominal hernia with a prosthesis in potentially infected tissues—a series of 47 cases. Hernia 1:157–161CrossRef Vix J, Meyer Ch, Rohr S, Bourtoul Ch (1997) The treatment of incisional and abdominal hernia with a prosthesis in potentially infected tissues—a series of 47 cases. Hernia 1:157–161CrossRef
19.
go back to reference Geisler DJ, Reilly JC, Vaughan SG, Glennon EJ, Kondylis PD (2003) Safety and outcome of use of nonabsorbable mesh for repair of fascial defects in the presence of open bowel. Dis Colon Rectum 46:1118–1123PubMedCrossRef Geisler DJ, Reilly JC, Vaughan SG, Glennon EJ, Kondylis PD (2003) Safety and outcome of use of nonabsorbable mesh for repair of fascial defects in the presence of open bowel. Dis Colon Rectum 46:1118–1123PubMedCrossRef
20.
go back to reference Kasperk R, Klinge U, Schumpelick V (2000) The repair of large parastomal hernias using a midline approach and a prosthetic mesh in the sublay position. Am J Surg 179:186–188PubMedCrossRef Kasperk R, Klinge U, Schumpelick V (2000) The repair of large parastomal hernias using a midline approach and a prosthetic mesh in the sublay position. Am J Surg 179:186–188PubMedCrossRef
21.
go back to reference Serra-Aracil X, Bombardo-Junca J, Moreno-Matias J, Darnell A, Mora-Lopez L, Alcantara-Moral M, Ayguavives-Garnica I, Navarro-Soto S (2009) Randomized, controlled, prospective trial of the use of a mesh to prevent parastomal hernia. Ann Surg 249:583–587PubMedCrossRef Serra-Aracil X, Bombardo-Junca J, Moreno-Matias J, Darnell A, Mora-Lopez L, Alcantara-Moral M, Ayguavives-Garnica I, Navarro-Soto S (2009) Randomized, controlled, prospective trial of the use of a mesh to prevent parastomal hernia. Ann Surg 249:583–587PubMedCrossRef
22.
go back to reference Jänes A, Cengiz Y, Israelsson LA (2009) Preventing parastomal hernia with a prosthetic mesh: a 5-year follow-up of a randomized study. World J Surg 33:118–121PubMedCrossRef Jänes A, Cengiz Y, Israelsson LA (2009) Preventing parastomal hernia with a prosthetic mesh: a 5-year follow-up of a randomized study. World J Surg 33:118–121PubMedCrossRef
23.
go back to reference Franklin ME Jr, Treviño JM, Portillo G, Vela I, Glass JL, González JJ (2008) The use of porcine small intestinal submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow-up. Surg Endosc 22:1941–1946PubMedCrossRef Franklin ME Jr, Treviño JM, Portillo G, Vela I, Glass JL, González JJ (2008) The use of porcine small intestinal submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow-up. Surg Endosc 22:1941–1946PubMedCrossRef
24.
go back to reference Guirao X, Arias J, Badía JM, García-Rodríguez JA, Mensa J, Alvarez-Lerma F, Borges M, Barberán J, Maseda E, Salavert M, Llinares P, Gobernado M, García Rey C (2010) Recommendations in the empiric anti-infective agents of intra-abdominal infection. Cir Esp 87:63–81PubMedCrossRef Guirao X, Arias J, Badía JM, García-Rodríguez JA, Mensa J, Alvarez-Lerma F, Borges M, Barberán J, Maseda E, Salavert M, Llinares P, Gobernado M, García Rey C (2010) Recommendations in the empiric anti-infective agents of intra-abdominal infection. Cir Esp 87:63–81PubMedCrossRef
25.
go back to reference Bleichrodt RP, Simmermacher RK, van der Lei B, Schakenraad JM (1993) Expanded polytetrafluoroethylene patch versus polypropylene mesh for the repair of contaminated defects of the abdominal wall. Surg Gynecol Obstet 176:18–24PubMed Bleichrodt RP, Simmermacher RK, van der Lei B, Schakenraad JM (1993) Expanded polytetrafluoroethylene patch versus polypropylene mesh for the repair of contaminated defects of the abdominal wall. Surg Gynecol Obstet 176:18–24PubMed
26.
go back to reference Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63:765–771PubMedCrossRef Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V (2002) Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. J Biomed Mater Res 63:765–771PubMedCrossRef
27.
go back to reference Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18:211–220PubMedCrossRef Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18:211–220PubMedCrossRef
28.
go back to reference Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef
29.
go back to reference Stone HH, Fabian TC, Turkleson ML, Jurkiewicz MJ (1981) Management of acute full-thickness losses of the abdominal wall. Ann Surg 193:612–618PubMedCrossRef Stone HH, Fabian TC, Turkleson ML, Jurkiewicz MJ (1981) Management of acute full-thickness losses of the abdominal wall. Ann Surg 193:612–618PubMedCrossRef
30.
go back to reference Schmitt HJ Jr, Grinnan GL (1967) Use of Marlex mesh in infected abdominal war wound. Am J Surg 113:825–828PubMedCrossRef Schmitt HJ Jr, Grinnan GL (1967) Use of Marlex mesh in infected abdominal war wound. Am J Surg 113:825–828PubMedCrossRef
31.
go back to reference Coda A, Bendavid R, Botto-Micca F, Bossotti M, Bona A (2003) Structural alterations of prosthetic meshes in humans. Hernia 7:29–34PubMed Coda A, Bendavid R, Botto-Micca F, Bossotti M, Bona A (2003) Structural alterations of prosthetic meshes in humans. Hernia 7:29–34PubMed
32.
go back to reference Bellón JM, García-Carranza A, García-Honduvilla N, Carrera-San Martín A, Buján J (2004) Tissue integration and biomechanical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants. Br J Surg 91:489–494PubMedCrossRef Bellón JM, García-Carranza A, García-Honduvilla N, Carrera-San Martín A, Buján J (2004) Tissue integration and biomechanical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants. Br J Surg 91:489–494PubMedCrossRef
33.
go back to reference Bellón JM, Rodríguez M, García-Honduvilla N, Gómez-Gil V, Pascual G, Buján J (2009) Comparing the behavior of different polypropylene meshes (heavy and lightweight) in an experimental model of ventral hernia repair. J Biomed Mater Res B Appl Biomater 89B:448–455PubMedCrossRef Bellón JM, Rodríguez M, García-Honduvilla N, Gómez-Gil V, Pascual G, Buján J (2009) Comparing the behavior of different polypropylene meshes (heavy and lightweight) in an experimental model of ventral hernia repair. J Biomed Mater Res B Appl Biomater 89B:448–455PubMedCrossRef
Metadata
Title
Searching for the best polypropylene mesh to be used in bowel contamination
Authors
A. Díaz-Godoy
M. Á. García-Ureña
J. López-Monclús
V. Vega Ruíz
D. Melero Montes
N. Erquinigo Agurto
Publication date
01-04-2011
Publisher
Springer-Verlag
Published in
Hernia / Issue 2/2011
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-010-0762-0

Other articles of this Issue 2/2011

Hernia 2/2011 Go to the issue