Purpose We describe a scleral suture fixation technique for dislocated plate haptic toric intraocular lens (IOL) implantation. Materials and methods A double-armed 10-0 straight polypropylene suture was passed into the eye from the sclera (2 mm away from the limbus). A suture needle was passed through the hole on the corner of the IOL and pulled out from the paracentesis with a 27-gauge needle. Afterward, the suture needle was reinserted from the same paracentesis and then removed from the eye with the help of a 27-gauge needle entering the eye from a nearby point to the first scleral entrance. The needle was passed through the end of the loop and pulled slightly to initiate the formation of a cow-hitch knot. The same procedure was applied to the other hole on the plate haptic. Both sutures were adjusted and fixed to the sclera with a Z suture. Results No complications were observed and at the follow-up visits, uncorrected visual acuity was 0.8 with decimal. Conclusion Axial, sagittal, and rotational stability rules are taken into consideration, scleral fixation surgery for a dislocated plate haptic foldable toric IOL is an alternative method to eliminate astigmatic refractive error.
Literature
1.
go back to reference Kessel L, Andresen J, Tendal B et al (2016) Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 123:275–286CrossRefPubMedCentral Kessel L, Andresen J, Tendal B et al (2016) Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 123:275–286CrossRefPubMedCentral
2.
go back to reference Lam DK, Chow VW, Ye C et al (2016) Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and ≤3 dioptres of astigmatism. Br J Ophthalmol 100:258–262CrossRefPubMedCentral Lam DK, Chow VW, Ye C et al (2016) Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and ≤3 dioptres of astigmatism. Br J Ophthalmol 100:258–262CrossRefPubMedCentral
3.
go back to reference Sagiv O, Sachs D (2015) Rotation stability of a toric intraocular lens with a second capsular tension ring. J Cataract Refract Surg 41:1098–1099CrossRefPubMedCentral Sagiv O, Sachs D (2015) Rotation stability of a toric intraocular lens with a second capsular tension ring. J Cataract Refract Surg 41:1098–1099CrossRefPubMedCentral
4.
go back to reference Arjmand P, Chan TY, Ahmed II (2015) Transscleral suture fixation following recurrent toric intraocular lens rotation. J Cataract Refract Surg 41:912–917CrossRefPubMedCentral Arjmand P, Chan TY, Ahmed II (2015) Transscleral suture fixation following recurrent toric intraocular lens rotation. J Cataract Refract Surg 41:912–917CrossRefPubMedCentral
5.
go back to reference Li PH, Tseng GL, Wu SC et al (2016) 27-Gauge needle-assisted technique for repositioning a dislocated intraocular lens. Retina 36:1791–1795CrossRefPubMedCentral Li PH, Tseng GL, Wu SC et al (2016) 27-Gauge needle-assisted technique for repositioning a dislocated intraocular lens. Retina 36:1791–1795CrossRefPubMedCentral
6.
go back to reference Dajee KP, Abbey AM, Williams GA (2016) Management of dislocated intraocular lenses in eyes with insufficient capsular support. Curr Opin Ophthalmol 27:191–195CrossRefPubMedCentral Dajee KP, Abbey AM, Williams GA (2016) Management of dislocated intraocular lenses in eyes with insufficient capsular support. Curr Opin Ophthalmol 27:191–195CrossRefPubMedCentral
7.
go back to reference Karadag R, Celik HU, Bayramlar H et al (2016) Sutureless intrascleral fixated intraocular lens implantation. J Refract Surg 32:586–597CrossRefPubMedCentral Karadag R, Celik HU, Bayramlar H et al (2016) Sutureless intrascleral fixated intraocular lens implantation. J Refract Surg 32:586–597CrossRefPubMedCentral
8.
9.
10.
go back to reference Kelkar A, Shah R, Kelkar J et al (2015) Sutureless, glueless, scleral fixation of single-piece and toric intraocular lens: a novel technique. Case Rep Ophthalmol 6:239–245CrossRefPubMedCentral Kelkar A, Shah R, Kelkar J et al (2015) Sutureless, glueless, scleral fixation of single-piece and toric intraocular lens: a novel technique. Case Rep Ophthalmol 6:239–245CrossRefPubMedCentral
Metadata
Title
Scleral suture fixation technique for dislocated plate haptic toric IOL
Authors
Remzi Karadag
Bahar Gunes
Veysel Aykut
Halit Oguz
Ahmet Demirok
Publication date
01-10-2018
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 5/2018
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0680-6

Other articles of this Issue 5/2018

International Ophthalmology 5/2018 Go to the issue