Skip to main content
Top
Published in: International Ophthalmology 2/2020

01-02-2020 | Original Paper

Sagittal height differences of disposable soft contact lenses

Authors: Stefano Giovanzana, Ştefan Ţălu, Simona Delia Nicoară

Published in: International Ophthalmology | Issue 2/2020

Login to get access

Abstract

Purpose

We aim to improve contact lens fitting by using an innovative and simple photogrammetry imaging system to find the sagittal height (SAG) of soft contact lenses.

Methods

Eleven different types of commercially available soft contact lenses were measured, and five different lenses per package of each lens type were evaluated. The lenses were inserted in a polymethyl methacrylate cell with parallel faces containing a solution of saline and fluorescein to improve the contrast against the background. For every lens, two photographs from the top view and five photographs from the side view were taken. Using homothetic transformations, we calculated the sagittal height.

Results

The SAG of all lenses ranged from 3450 to 3907 μm. Differences can be appreciated between SAG of different materials. Performing an ANOVA test, we confirm that the intra-packaging sagitta is reliable for every lens. Comparing the measured SAG with the calculated spherical one, we confirm that the majority of lenses, eight out of eleven, have a spherical geometry for the internal side. Finally, we are able to group the type of lenses that present similar SAG apart from the data reported on the blister.

Conclusion

Optical coherence tomography measurement of the eye sagitta over a given chord helped finding the first lens to fit, because matching contact lens sagitta and ocular sagitta is the key for a good fitting. In our work, we found that the majority of brands use single sphere geometry for internal surface of disposable soft contact lenses.
Literature
1.
go back to reference Ţălu SD (2005) Ophtalmologie—cours, medical publishing house. Iuliu Haţieganu, Cluj-Napoca Ţălu SD (2005) Ophtalmologie—cours, medical publishing house. Iuliu Haţieganu, Cluj-Napoca
3.
go back to reference Ţălu Ş, Ţălu M, Giovanzana S, Shah R (2011) A brief history of contact lenses. HVM Bioflux 3(1):33–37 Ţălu Ş, Ţălu M, Giovanzana S, Shah R (2011) A brief history of contact lenses. HVM Bioflux 3(1):33–37
4.
go back to reference Efron N (2010) Contact lens practice, 2nd edn. Butterworth Heinemann Elsevier, Oxford Efron N (2010) Contact lens practice, 2nd edn. Butterworth Heinemann Elsevier, Oxford
5.
go back to reference Ţălu Ş (2013) Characterization of surface roughness of unworn hydrogel contact lenses at a nanometric scale using methods of modern metrology. Polym Eng Sci 53:2141–2150 Ţălu Ş (2013) Characterization of surface roughness of unworn hydrogel contact lenses at a nanometric scale using methods of modern metrology. Polym Eng Sci 53:2141–2150
6.
go back to reference Douthwaite WA (2006) Contact lens optics and lens design, 3rd edn. Butterworth Heinemann Elsevier, Oxford Douthwaite WA (2006) Contact lens optics and lens design, 3rd edn. Butterworth Heinemann Elsevier, Oxford
7.
go back to reference Ţălu Ş, Stępień K, Caglayan MO (2015) Topographic characterization of unworn contact lenses assessed by atomic force microscopy and wavelet transform. Microsc Res Tech 78:1026–1031CrossRef Ţălu Ş, Stępień K, Caglayan MO (2015) Topographic characterization of unworn contact lenses assessed by atomic force microscopy and wavelet transform. Microsc Res Tech 78:1026–1031CrossRef
8.
go back to reference Ţălu Ş, Stach S (2014) Multifractal characterization of unworn hydrogel contact lens surfaces. Polym Eng Sci 54:1066–1080CrossRef Ţălu Ş, Stach S (2014) Multifractal characterization of unworn hydrogel contact lens surfaces. Polym Eng Sci 54:1066–1080CrossRef
9.
go back to reference Ţălu Ş (2012) Texture analysis methods for the characterisation of biological and medical images. ELBA Bioflux 4(1):8–12 Ţălu Ş (2012) Texture analysis methods for the characterisation of biological and medical images. ELBA Bioflux 4(1):8–12
10.
go back to reference Ţălu Ş, Bramowicz M, Kulesza S, Fiorillo I, Giovanzana S (2017) Fractal features and surface micromorphology of unworn surfaces of rigid gas permeable contact lenses. Curr Eye Res 42(8):1118–1123CrossRef Ţălu Ş, Bramowicz M, Kulesza S, Fiorillo I, Giovanzana S (2017) Fractal features and surface micromorphology of unworn surfaces of rigid gas permeable contact lenses. Curr Eye Res 42(8):1118–1123CrossRef
11.
go back to reference Filipecki J, Sitarz M, Kocela A, Kotynia K, Jelen P, Filipecka K, Gaweda M (2014) Studying functional properties of hydrogel and silicone-hydrogel contact lenses with PALS, MIR and Raman spectroscopy. Spectrochim Acta A Mol Biomol Spectrosc 131:686–690CrossRef Filipecki J, Sitarz M, Kocela A, Kotynia K, Jelen P, Filipecka K, Gaweda M (2014) Studying functional properties of hydrogel and silicone-hydrogel contact lenses with PALS, MIR and Raman spectroscopy. Spectrochim Acta A Mol Biomol Spectrosc 131:686–690CrossRef
12.
go back to reference Ţălu Ş (2012) Mathematical methods used in monofractal and multifractal analysis for the processing of biological and medical data and images. Anim Biol Anim Husb 4(1):1–4 Ţălu Ş (2012) Mathematical methods used in monofractal and multifractal analysis for the processing of biological and medical data and images. Anim Biol Anim Husb 4(1):1–4
13.
go back to reference Young G (1992) Ocular sagittal height and soft contact lens fit. J BCLA 15:45–49 Young G (1992) Ocular sagittal height and soft contact lens fit. J BCLA 15:45–49
14.
go back to reference Young G (2014) Mathematical model for evaluating soft contact lens fit. Optom Vis Sci 91:167–176CrossRef Young G (2014) Mathematical model for evaluating soft contact lens fit. Optom Vis Sci 91:167–176CrossRef
15.
go back to reference Van der Worp E (2010) A guide to scleral lens fitting. Pacific University, Forest Grove Van der Worp E (2010) A guide to scleral lens fitting. Pacific University, Forest Grove
16.
go back to reference Hall LA, Hunt C, Young G, Wolffsohn J (2013) Factors affecting corneoscleral topography. Invest Ophthalmol Vis Sci 54:3691–3701CrossRef Hall LA, Hunt C, Young G, Wolffsohn J (2013) Factors affecting corneoscleral topography. Invest Ophthalmol Vis Sci 54:3691–3701CrossRef
17.
go back to reference Bibby MM (1979) Sagittal depth considerations in the selection of the base curve radius of a soft contact lens. Am J Optom Vis Sci 56:407–413CrossRef Bibby MM (1979) Sagittal depth considerations in the selection of the base curve radius of a soft contact lens. Am J Optom Vis Sci 56:407–413CrossRef
18.
go back to reference Hall LA, Young G, Wolffsohn JS, Riley C (2011) The influence of corneoscleral topography on soft contact lens fit. Invest Ophthalmol Vis Sci 52:6801–6806CrossRef Hall LA, Young G, Wolffsohn JS, Riley C (2011) The influence of corneoscleral topography on soft contact lens fit. Invest Ophthalmol Vis Sci 52:6801–6806CrossRef
19.
go back to reference Young G, Schnider C, Hunt C, Efron S (2010) Corneal topography and soft contact lens fit. Optom Vis Sci 87:358–366PubMed Young G, Schnider C, Hunt C, Efron S (2010) Corneal topography and soft contact lens fit. Optom Vis Sci 87:358–366PubMed
20.
go back to reference Sorbara L, Maram J, Fonn D, Woods C, Simpson T (2010) Metrics of the normal cornea: anterior segment imaging with the Visante OCT. Clin Exp Optom 93:150–156CrossRef Sorbara L, Maram J, Fonn D, Woods C, Simpson T (2010) Metrics of the normal cornea: anterior segment imaging with the Visante OCT. Clin Exp Optom 93:150–156CrossRef
21.
go back to reference Luhmann T, Robson S, Kyle SA, Harley IA (2007) Close range photogrammetry: principles, techniques and applications. Whittles, Dunbeath Luhmann T, Robson S, Kyle SA, Harley IA (2007) Close range photogrammetry: principles, techniques and applications. Whittles, Dunbeath
22.
go back to reference Ţălu Ş (2015) Micro and nanoscale characterization of three dimensional surfaces. Basics and applications. Napoca Star Publishing House, Cluj-Napoca Ţălu Ş (2015) Micro and nanoscale characterization of three dimensional surfaces. Basics and applications. Napoca Star Publishing House, Cluj-Napoca
23.
go back to reference Phillips AJ, Speedwell L (2018) Contact lenses e-book. Elsevier Health Sciences, Oxford Phillips AJ, Speedwell L (2018) Contact lenses e-book. Elsevier Health Sciences, Oxford
24.
go back to reference Van der Worp E, Mertz C (2015) Sagittal height differences of frequent replacement silicone hydrogel contact lenses. Contact Lens Anterio 38:157–162CrossRef Van der Worp E, Mertz C (2015) Sagittal height differences of frequent replacement silicone hydrogel contact lenses. Contact Lens Anterio 38:157–162CrossRef
Metadata
Title
Sagittal height differences of disposable soft contact lenses
Authors
Stefano Giovanzana
Ştefan Ţălu
Simona Delia Nicoară
Publication date
01-02-2020
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 2/2020
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-019-01206-5

Other articles of this Issue 2/2020

International Ophthalmology 2/2020 Go to the issue