Skip to main content
Top
Published in: Journal of Digital Imaging 4/2015

01-08-2015

Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint

Authors: Cheng Chen, Risto Kojcev, Daniel Haschtmann, Tamas Fekete, Lutz Nolte, Guoyan Zheng

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2015

Login to get access

Abstract

In this paper, we propose a new method for stitching multiple fluoroscopic images taken by a C-arm instrument. We employ an X-ray radiolucent ruler with numbered graduations while acquiring the images, and the image stitching is based on detecting and matching ruler parts in the images to the corresponding parts of a virtual ruler. To achieve this goal, we first detect the regular spaced graduations on the ruler and the numbers. After graduation labeling, for each image, we have the location and the associated number for every graduation on the ruler. Then, we initialize the panoramic X-ray image with the virtual ruler, and we “paste” each image by aligning the detected ruler part on the original image, to the corresponding part of the virtual ruler on the panoramic image. Our method is based on ruler matching but without the requirement of matching similar feature points in pairwise images, and thus, we do not necessarily require overlap between the images. We tested our method on eight different datasets of X-ray images, including long bones and a complete spine. Qualitative and quantitative experiments show that our method achieves good results.
Footnotes
1
Since we already detected the main line of the ruler and we know the numbers appear only below this line, we could also reduce the search region using this information.
 
Literature
1.
go back to reference Ricci WM, Bellabarba C, Lewis R, Evanoff B, Herscovici D, Dipasquale T, Sanders R: Angular malalignment after intramedullary nailing of femoral shaft fractures. J Orthop Trauma 15(2):90–95, 2001PubMedCrossRef Ricci WM, Bellabarba C, Lewis R, Evanoff B, Herscovici D, Dipasquale T, Sanders R: Angular malalignment after intramedullary nailing of femoral shaft fractures. J Orthop Trauma 15(2):90–95, 2001PubMedCrossRef
2.
go back to reference Wang L, Traub J, Weidert S, Heining SM, Euler E, Navab N: Parallax-free intra-operative x-ray image stitching. Med Image Anal 14(5):674–686, 2010PubMedCrossRef Wang L, Traub J, Weidert S, Heining SM, Euler E, Navab N: Parallax-free intra-operative x-ray image stitching. Med Image Anal 14(5):674–686, 2010PubMedCrossRef
3.
go back to reference Szeliski R: Image alignment and stitching: a tutorial. Found Trends Comput Graph 2(1):1–104, 2006CrossRef Szeliski R: Image alignment and stitching: a tutorial. Found Trends Comput Graph 2(1):1–104, 2006CrossRef
4.
go back to reference Yaniv Z, Joskowicz L: Long bone panoramas from fluoroscopic X-ray images. IEEE Trans Med Imaging 23(1):26–35, 2004PubMedCrossRef Yaniv Z, Joskowicz L: Long bone panoramas from fluoroscopic X-ray images. IEEE Trans Med Imaging 23(1):26–35, 2004PubMedCrossRef
5.
go back to reference Eeuwijk AHW, Lobregt S, Gerritsen FA: A novel method for digital x-ray imaging of the complete spine. Lect Notes Comput Sci 1205:519–530, 1997CrossRef Eeuwijk AHW, Lobregt S, Gerritsen FA: A novel method for digital x-ray imaging of the complete spine. Lect Notes Comput Sci 1205:519–530, 1997CrossRef
6.
go back to reference Gooßen A, Schlüter M, Hensel M. Pralow T, Grigat R: Ruler-Based Automatic Stitching of Spatially Overlapping Radiographs. Bildverarbeitung fr die Medizin, 2008 Gooßen A, Schlüter M, Hensel M. Pralow T, Grigat R: Ruler-Based Automatic Stitching of Spatially Overlapping Radiographs. Bildverarbeitung fr die Medizin, 2008
7.
go back to reference Verdonck B, Nijlunsing R, Melman N, Geijer H: Image quality and x-ray dose for translation reconstruction overview imaging of the spine, colon and legs. Int. Congr. Ser 1230:531–537, 2001CrossRef Verdonck B, Nijlunsing R, Melman N, Geijer H: Image quality and x-ray dose for translation reconstruction overview imaging of the spine, colon and legs. Int. Congr. Ser 1230:531–537, 2001CrossRef
8.
go back to reference Qi Z, Cooperstock J: Overcoming parallax and sampling density issues in image mosaicing of non-planar scenes. Br Mach Vis Conf. 2007 Qi Z, Cooperstock J: Overcoming parallax and sampling density issues in image mosaicing of non-planar scenes. Br Mach Vis Conf. 2007
9.
go back to reference Harris C, Stephens M: A combined corner and edge detector. Proc. Fourth Alvey Vision Conference, 1988 Harris C, Stephens M: A combined corner and edge detector. Proc. Fourth Alvey Vision Conference, 1988
10.
go back to reference Dalal N, Triggs B: Histograms of oriented gradients for human detection. IEEE Comput Soc Conf Comput. Vis Pattern Recog, 2005 Dalal N, Triggs B: Histograms of oriented gradients for human detection. IEEE Comput Soc Conf Comput. Vis Pattern Recog, 2005
Metadata
Title
Ruler Based Automatic C-Arm Image Stitching Without Overlapping Constraint
Authors
Cheng Chen
Risto Kojcev
Daniel Haschtmann
Tamas Fekete
Lutz Nolte
Guoyan Zheng
Publication date
01-08-2015
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2015
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-014-9763-3

Other articles of this Issue 4/2015

Journal of Digital Imaging 4/2015 Go to the issue