Abstract

Purpose

The purpose of this study is to evaluate the incidence, risk factors, and salvage management of retrievable covered expandable metallic stent (RCEMS) migration in patients with persistent benign ureter strictures.

Materials and methods

A retrospective study was performed on 117 consecutive patients who underwent implantation of RCEMS. Univariate and multivariate analyses were used to identify prognostic factors for stent migration, including stricture location and length, hydronephrosis–cortex ratio, ureteral dilation, and the diameter of the narrowest portion of the stricture.

Results

Stent migration occurred in 22 (19.5%) of 113 patients who met inclusion criteria. Of the 22 patients, 16 (72.7%) had ordinary ureteral stricture, 3 (13.6%) had stricture in transplanted kidneys, and 3 patients (13.6%) had ureter stricture in orthotopic neobladders. The mean creatinine for the entire cohorts showed significant improvement (p = 0.038). Multivariate analysis identified the following prognostic factors for migration: distal ureteral stricture (p = 0.006), patients who underwent balloon dilation (p = 0.003), hydronephrosis–cortex ratio ≧10 (p = 0.017), larger diameter of wasting of RCEMS (p < 0.001), and patients with a shorter stricture length (p = 0.006). Salvage management was required in 4 of the 22 patients. The strictures in the remaining 18 patients improved with observation.

Conclusions

Stent migration is more likely to occur in patients with the five prognostic factors mentioned above. Our study developed a nomogram to predict stent migration in patients with ureteral strictures treated using RCEMS.
Literature
1.
go back to reference López-Huertas HL, Polcari AJ, Acosta-Miranda A, Turk TM (2010) Metallic ureteral stents: a cost-effective method of managing benign upper tract obstruction. J Endourol 24:483–485CrossRefPubMed López-Huertas HL, Polcari AJ, Acosta-Miranda A, Turk TM (2010) Metallic ureteral stents: a cost-effective method of managing benign upper tract obstruction. J Endourol 24:483–485CrossRefPubMed
2.
go back to reference Miyazaki J, Onozawa M, Takahashi S, Maekawa Y, Yasuda M, Wada K et al (2019) The resonance® metallic ureteral stent in the treatment of malignant ureteral obstruction: a prospective observational study. BMC Urol 19:137CrossRefPubMedPubMedCentral Miyazaki J, Onozawa M, Takahashi S, Maekawa Y, Yasuda M, Wada K et al (2019) The resonance® metallic ureteral stent in the treatment of malignant ureteral obstruction: a prospective observational study. BMC Urol 19:137CrossRefPubMedPubMedCentral
3.
go back to reference Wang W, Gao X, Chen J, Liu Z, Peng L, Wei X (2021) Metal stent for the ureteral stricture after surgery and/or radiation treatment for malignancy. BMC Urol 21:146CrossRefPubMedPubMedCentral Wang W, Gao X, Chen J, Liu Z, Peng L, Wei X (2021) Metal stent for the ureteral stricture after surgery and/or radiation treatment for malignancy. BMC Urol 21:146CrossRefPubMedPubMedCentral
4.
5.
go back to reference Corrales M, Doizi S, Barghouthy Y, Kamkoum H, Somani B, Traxer O (2021) A systematic review of long-duration stents for ureteral stricture: which one to choose? World J Urol 39:3197–3205CrossRefPubMed Corrales M, Doizi S, Barghouthy Y, Kamkoum H, Somani B, Traxer O (2021) A systematic review of long-duration stents for ureteral stricture: which one to choose? World J Urol 39:3197–3205CrossRefPubMed
6.
7.
go back to reference Wang HJ, Lee TY, Luo HL, Chen CH, Shen YC, Chuang YC et al (2011) Application of resonance metallic stents for ureteral obstruction. BJU Int 108:428–432CrossRefPubMed Wang HJ, Lee TY, Luo HL, Chen CH, Shen YC, Chuang YC et al (2011) Application of resonance metallic stents for ureteral obstruction. BJU Int 108:428–432CrossRefPubMed
8.
go back to reference Moskovitz B, Halachmi S, Nativ O (2012) A new self-expanding, large-caliber ureteral stent: results of a multicenter experience. J Endourol 26:1523–1527CrossRefPubMed Moskovitz B, Halachmi S, Nativ O (2012) A new self-expanding, large-caliber ureteral stent: results of a multicenter experience. J Endourol 26:1523–1527CrossRefPubMed
9.
10.
go back to reference Papadopoulos GI, Middela S, Srirangam SJ, Szczesniak CA, Rao PN (2010) Use of Memokath 051 metallic stent in the management of ureteral strictures: a single-center experience. Urol Int 84:286–291CrossRefPubMed Papadopoulos GI, Middela S, Srirangam SJ, Szczesniak CA, Rao PN (2010) Use of Memokath 051 metallic stent in the management of ureteral strictures: a single-center experience. Urol Int 84:286–291CrossRefPubMed
11.
go back to reference Giessing M (2011) Transplant ureter stricture following renal transplantation: surgical options. Transpl Proc 43:383–386CrossRef Giessing M (2011) Transplant ureter stricture following renal transplantation: surgical options. Transpl Proc 43:383–386CrossRef
12.
go back to reference Zhong Q, Song T, Zeng J, Lin T, Fan Y, Wei X (2021) Initial experiment of self-expanding metal ureteral stent in recurrent ureteral stenosis after kidney transplantation. Am J Trans Off J Am Soc Trans Am Soc Trans Surg 21:1983–1984CrossRef Zhong Q, Song T, Zeng J, Lin T, Fan Y, Wei X (2021) Initial experiment of self-expanding metal ureteral stent in recurrent ureteral stenosis after kidney transplantation. Am J Trans Off J Am Soc Trans Am Soc Trans Surg 21:1983–1984CrossRef
13.
go back to reference Cao C, Kim JW, Shin JH, Li M, Hong B, Kim YH et al (2020) Temporary covered metallic ureteral stent placement for ureteral strictures following kidney transplantation: experience in 8 patients. J Vasc Interv Radiol JVIR 31:1795–1800CrossRefPubMed Cao C, Kim JW, Shin JH, Li M, Hong B, Kim YH et al (2020) Temporary covered metallic ureteral stent placement for ureteral strictures following kidney transplantation: experience in 8 patients. J Vasc Interv Radiol JVIR 31:1795–1800CrossRefPubMed
14.
go back to reference Peng YL, Ning K, Wu ZS, Li ZY, Deng MH, Xiong LB et al (2021) Ureteral stents cannot decrease the incidence of ureteroileal anastomotic stricture and leakage: a systematic review and meta-analysis. Int J Surg 93:106058CrossRefPubMed Peng YL, Ning K, Wu ZS, Li ZY, Deng MH, Xiong LB et al (2021) Ureteral stents cannot decrease the incidence of ureteroileal anastomotic stricture and leakage: a systematic review and meta-analysis. Int J Surg 93:106058CrossRefPubMed
15.
go back to reference Dong WM, Wang MR, Hu H, Wang Q, Xu KX, Xu T (2020) Initial clinical experience and follow-up outcomes of treatment for ureteroileal anastomotic stricture with Allium coated metal ureteral stent. Beijing Da Xue Xue Bao Yi Xue Ban 52:637–641PubMed Dong WM, Wang MR, Hu H, Wang Q, Xu KX, Xu T (2020) Initial clinical experience and follow-up outcomes of treatment for ureteroileal anastomotic stricture with Allium coated metal ureteral stent. Beijing Da Xue Xue Bao Yi Xue Ban 52:637–641PubMed
Metadata
Title
Risk factors for migration of retrievable covered expandable metallic stent in patients with persistent benign ureter strictures
Authors
Yuyu Xu
Xiezhao Li
Zhiduan Cai
Shuangxing Chen
Rui Zhu
Haishan Zhuang
ShawPong Wan
Guibin Xu
Publication date
01-12-2024
Publisher
Springer Berlin Heidelberg
Published in
World Journal of Urology / Issue 1/2024
Print ISSN: 0724-4983
Electronic ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-024-04986-3

Other articles of this Issue 1/2024

World Journal of Urology 1/2024 Go to the issue