Skip to main content
Top
Published in: Acta Neurochirurgica 1/2009

01-01-2009 | Clinical Article

Risk factors for complications during intracranial electrode recording in presurgical evaluation of drug resistant partial epilepsy

Authors: Chong H. Wong, Julie Birkett, Karen Byth, Mark Dexter, Ernest Somerville, Deepak Gill, Ray Chaseling, Michael Fearnside, Andrew Bleasel

Published in: Acta Neurochirurgica | Issue 1/2009

Login to get access

Abstract

Background

Intracranial electrode monitoring is still required in epilepsy surgery; however, it is associated with significant morbidity.

Objective

To identify risk factors associated with complications during invasive intracranial EEG monitoring.

Materials and methods

Retrospective study of all patients undergoing invasive monitoring at Westmead between 1988–2004. From detailed chart reviews, the following variables were recorded: duration of intracranial monitoring, the site of grid implantation, number of grids and electrodes, seizure frequency, postoperative complications and seizure outcome.

Results

Seventy-one patients (median age: 24 years) underwent subdural electrode implantation; 62% had extratemporal lobe epilepsy and 46% were non-lesional. Of the 58 monitored patients who had cortical resections, 45 had good seizure outcomes. Complications related to subdural electrode implantation included transient complications requiring no treatment (12.7%), transient complications requiring treatment (9.9%) and two deaths (2.8%). Specific complications included subdural haemorrhage, transient neurological deficit, infarction and osteomyelitis. The two deaths occurred within 48 h of implantation were related to raised intracranial pressure (one venous infarction, one unexplained). Complications were associated with maximal size of grid (p < 0.001), greater number of electrodes (p < 0.001), electrode density per cortical surface implanted (p < 0.001), right central surface implantation (p = 0.003) and left central surface implantation (p = 0.013). Multiple logistic regression identified larger size grids and right central surface implantation as independent predictors of complications.

Conclusion

There are significant complications during intracranial EEG evaluations but the majority of these are transient. We found a relationship between the size of the electrode arrays and the incidence of complications. The results of this study have been used to modify our implantation and monitoring protocols.
Literature
1.
go back to reference Adelson PD, Black PM, Madsen JR, Kramer U, Rockoff MA, Riviello JJ, Helmers SL, Mikati M, Holmes GL (1995) Use of subdural grids and strip electrodes to identify a seizure focus in children. Pediatr Neurosurg 22:174–180PubMedCrossRef Adelson PD, Black PM, Madsen JR, Kramer U, Rockoff MA, Riviello JJ, Helmers SL, Mikati M, Holmes GL (1995) Use of subdural grids and strip electrodes to identify a seizure focus in children. Pediatr Neurosurg 22:174–180PubMedCrossRef
2.
go back to reference Alarcon G, Valentin A, Watt C, Selway RP, Lacruz ME, Elwes RD, Jarosz JM, Honavar M, Brunhuber F, Mullatti N, Bodi I, Salinas M, Binnie CD, Polkey CE (2006) Is it worth pursuing surgery for epilepsy in patients with normal neuroimaging? J Neurol Neurosurg Psychiatry 77:474–480PubMedCrossRef Alarcon G, Valentin A, Watt C, Selway RP, Lacruz ME, Elwes RD, Jarosz JM, Honavar M, Brunhuber F, Mullatti N, Bodi I, Salinas M, Binnie CD, Polkey CE (2006) Is it worth pursuing surgery for epilepsy in patients with normal neuroimaging? J Neurol Neurosurg Psychiatry 77:474–480PubMedCrossRef
3.
go back to reference Albright AL, Pollack IF, Adelson PD, Solot JJ (1999) Outcome data and analysis in pediatric neurosurgery. Neurosurgery 45:101–106PubMedCrossRef Albright AL, Pollack IF, Adelson PD, Solot JJ (1999) Outcome data and analysis in pediatric neurosurgery. Neurosurgery 45:101–106PubMedCrossRef
4.
go back to reference Araki T, Otsubo H, Makino Y, Elliott I, Iida K, Ochi A, Weiss SK, Chuang SH, Rutka JT, Snead OC 3rd (2006) Efficacy of dexamathasone on cerebral swelling and seizures during subdural grid EEG recording in children. Epilepsia 47:176–180PubMedCrossRef Araki T, Otsubo H, Makino Y, Elliott I, Iida K, Ochi A, Weiss SK, Chuang SH, Rutka JT, Snead OC 3rd (2006) Efficacy of dexamathasone on cerebral swelling and seizures during subdural grid EEG recording in children. Epilepsia 47:176–180PubMedCrossRef
5.
go back to reference Aszalos Z, Barsi P, Vitrai J, Nagy Z (2002) Lateralization as a factor in the prognosis of middle cerebral artery territorial infarct. Eur Neurol 48:141–145PubMedCrossRef Aszalos Z, Barsi P, Vitrai J, Nagy Z (2002) Lateralization as a factor in the prognosis of middle cerebral artery territorial infarct. Eur Neurol 48:141–145PubMedCrossRef
6.
go back to reference Bauman JA, Feoli E, Romanelli P, Doyle WK, Devinsky O, Weiner HL (2005) Multistage epilepsy surgery: safety, efficacy, and utility of a novel approach in pediatric extratemporal epilepsy. Neurosurgery 56:318–334PubMedCrossRef Bauman JA, Feoli E, Romanelli P, Doyle WK, Devinsky O, Weiner HL (2005) Multistage epilepsy surgery: safety, efficacy, and utility of a novel approach in pediatric extratemporal epilepsy. Neurosurgery 56:318–334PubMedCrossRef
7.
go back to reference Behrens E, Schramm J, Zentner J, Konig R (1997) Surgical and neurological complications in a series of 708 epilepsy surgery procedures. Neurosurgery 41:1–9, discussion 9-10PubMedCrossRef Behrens E, Schramm J, Zentner J, Konig R (1997) Surgical and neurological complications in a series of 708 epilepsy surgery procedures. Neurosurgery 41:1–9, discussion 9-10PubMedCrossRef
8.
go back to reference Bird JM, Dembny KAT, Sandeman D, Butler S (1997) Sudden unexplained death in epilepsy: an intracranially monitored case. Epilepsia 38: Supp II: S52–S56 597 Bird JM, Dembny KAT, Sandeman D, Butler S (1997) Sudden unexplained death in epilepsy: an intracranially monitored case. Epilepsia 38: Supp II: S52–S56 597
9.
go back to reference Blatt DR, Roper SN, Friedman WA (1997) Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique. Surg Neurol 48:74–79PubMedCrossRef Blatt DR, Roper SN, Friedman WA (1997) Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique. Surg Neurol 48:74–79PubMedCrossRef
10.
go back to reference Burneo JG, Steven DA, McLachlan RS, Parrent AG (2006) Morbidity associated with the use of intracranial electrodes for epilepsy surgery. Can J Neurol Sci 33:223–227PubMed Burneo JG, Steven DA, McLachlan RS, Parrent AG (2006) Morbidity associated with the use of intracranial electrodes for epilepsy surgery. Can J Neurol Sci 33:223–227PubMed
11.
go back to reference Di Legge S, Saposnik G, Nilanont Y, Hachinski V (2006) Neglecting the difference: does right or left matter in stroke outcome after thrombolysis? Stroke 37:2066–2069PubMedCrossRef Di Legge S, Saposnik G, Nilanont Y, Hachinski V (2006) Neglecting the difference: does right or left matter in stroke outcome after thrombolysis? Stroke 37:2066–2069PubMedCrossRef
12.
go back to reference Engel J Jr, Crandall PH, Rausch R (1983) The partial epilepsies. Churchill, Livingston New York Engel J Jr, Crandall PH, Rausch R (1983) The partial epilepsies. Churchill, Livingston New York
13.
go back to reference Engel J Jr, Van Ness PC, Rasmussen TB, Ojemann LM (1993) Outcome with respect to epileptic seizures. Raven, New York, NY Engel J Jr, Van Ness PC, Rasmussen TB, Ojemann LM (1993) Outcome with respect to epileptic seizures. Raven, New York, NY
14.
go back to reference Flugel D, Ostertun B, Bauer J, van Roost D, Elger CE (1997) Iatrogenic brain prolapse: a rare complication of invasive presurgical evaluation of epilepsy. Neurology 48:785–786PubMed Flugel D, Ostertun B, Bauer J, van Roost D, Elger CE (1997) Iatrogenic brain prolapse: a rare complication of invasive presurgical evaluation of epilepsy. Neurology 48:785–786PubMed
15.
go back to reference Fountas KN, Smith JR (2007) Subdural electrode-associated complications: a 20-year experience. Stereotact Funct Neurosurg 85:264–272PubMedCrossRef Fountas KN, Smith JR (2007) Subdural electrode-associated complications: a 20-year experience. Stereotact Funct Neurosurg 85:264–272PubMedCrossRef
16.
go back to reference Fullagar T, Wyler AR (1993) Morbidity of long-term seizure monitoring using subdural strip electrodes: a follow-up. J Epilepsy 6:95–97CrossRef Fullagar T, Wyler AR (1993) Morbidity of long-term seizure monitoring using subdural strip electrodes: a follow-up. J Epilepsy 6:95–97CrossRef
17.
go back to reference Gabor AJ, Brooks AG, Scobey RP, Parsons GH (1984) Intracranial pressure during epileptic seizures. Electroencephalogr Clin Neurophysiol 57:497–506PubMedCrossRef Gabor AJ, Brooks AG, Scobey RP, Parsons GH (1984) Intracranial pressure during epileptic seizures. Electroencephalogr Clin Neurophysiol 57:497–506PubMedCrossRef
18.
go back to reference Hamer HM, Morris HH, Mascha EJ, Karafa MT, Bingaman WE, Bej MD, Burgess RC, Dinner DS, Foldvary NR, Hahn JF, Kotagal P, Najm I, Wyllie E, Luders HO (2002) Complications of invasive video-EEG monitoring with subdural grid electrodes. Neurology 58:97–103PubMed Hamer HM, Morris HH, Mascha EJ, Karafa MT, Bingaman WE, Bej MD, Burgess RC, Dinner DS, Foldvary NR, Hahn JF, Kotagal P, Najm I, Wyllie E, Luders HO (2002) Complications of invasive video-EEG monitoring with subdural grid electrodes. Neurology 58:97–103PubMed
19.
go back to reference Hennessy MJ, Langan Y, Elwes RD, Binnie CD, Polkey CE, Nashef L (1999) A study of mortality after temporal lobe epilepsy surgery. Neurology 53:1276–1283PubMed Hennessy MJ, Langan Y, Elwes RD, Binnie CD, Polkey CE, Nashef L (1999) A study of mortality after temporal lobe epilepsy surgery. Neurology 53:1276–1283PubMed
20.
go back to reference Jobst BC, Williamson PD, Coughlin CT, Thadani VM, Roberts DW (2000) An unusual complication of intracranial electrodes. Epilepsia 41:898–902PubMedCrossRef Jobst BC, Williamson PD, Coughlin CT, Thadani VM, Roberts DW (2000) An unusual complication of intracranial electrodes. Epilepsia 41:898–902PubMedCrossRef
21.
go back to reference Johnston JM Jr., Mangano FT, Ojemann JG, Park TS, Trevathan E, Smyth MD (2006) Complications of invasive subdural electrode monitoring at St. Louis Children’s Hospital, 1994–2005. J Neurosurg 105:343–347PubMed Johnston JM Jr., Mangano FT, Ojemann JG, Park TS, Trevathan E, Smyth MD (2006) Complications of invasive subdural electrode monitoring at St. Louis Children’s Hospital, 1994–2005. J Neurosurg 105:343–347PubMed
22.
go back to reference Lee MA (1998) EEG video recording of sudden unexpected death in epilepsy (SUDEP). Epilepsia 39: Supp 6: S123–124 Lee MA (1998) EEG video recording of sudden unexpected death in epilepsy (SUDEP). Epilepsia 39: Supp 6: S123–124
23.
go back to reference Lee SK, Lee SY, Kim KK, Hong KS, Lee DS, Chung CK (2005) Surgical outcome and prognostic factors of cryptogenic neocortical epilepsy. Ann Neurol 58:525–532PubMedCrossRef Lee SK, Lee SY, Kim KK, Hong KS, Lee DS, Chung CK (2005) Surgical outcome and prognostic factors of cryptogenic neocortical epilepsy. Ann Neurol 58:525–532PubMedCrossRef
24.
go back to reference Lee WS, Lee JK, Lee SA, Kang JK, Ko TS (2000) Complications and results of subdural grid electrode implantation in epilepsy surgery. Surg Neurol 54:346–351PubMedCrossRef Lee WS, Lee JK, Lee SA, Kang JK, Ko TS (2000) Complications and results of subdural grid electrode implantation in epilepsy surgery. Surg Neurol 54:346–351PubMedCrossRef
25.
go back to reference Leijten FSS, Spetgens WPJ, van Rijen PC, Gosselaar P, Vermeulen J, van Nieuwenhuizen O, van Huffelen AC (2006) Intracranial EEG monitoring for epilepsy surgery using electrode grids—results in the first 22 Dutch patients.[see comment]. Nederlands Tijdschrift voor Geneeskunde 150:2378–2385PubMed Leijten FSS, Spetgens WPJ, van Rijen PC, Gosselaar P, Vermeulen J, van Nieuwenhuizen O, van Huffelen AC (2006) Intracranial EEG monitoring for epilepsy surgery using electrode grids—results in the first 22 Dutch patients.[see comment]. Nederlands Tijdschrift voor Geneeskunde 150:2378–2385PubMed
26.
go back to reference Morrison G, Duchowny M, Resnick T, Alvarez L, Jayakar P, Prats AR, Dean P, Penate M (1992) Epilepsy surgery in childhood. A report of 79 patients. Pediatr Neurosurg 18:291–297PubMedCrossRef Morrison G, Duchowny M, Resnick T, Alvarez L, Jayakar P, Prats AR, Dean P, Penate M (1992) Epilepsy surgery in childhood. A report of 79 patients. Pediatr Neurosurg 18:291–297PubMedCrossRef
27.
go back to reference Musleh W, Yassari R, Hecox K, Kohrman M, Chico M, Frim D (2006) Low incidence of subdural grid-related complications in prolonged pediatric EEG monitoring. Pediatr Neurosurg 42:284–287PubMedCrossRef Musleh W, Yassari R, Hecox K, Kohrman M, Chico M, Frim D (2006) Low incidence of subdural grid-related complications in prolonged pediatric EEG monitoring. Pediatr Neurosurg 42:284–287PubMedCrossRef
28.
go back to reference Nilsson L, Ahlbom A, Farahmand BY, Tomson T (2003) Mortality in a population-based cohort of epilepsy surgery patients. Epilepsia 44:575–581PubMedCrossRef Nilsson L, Ahlbom A, Farahmand BY, Tomson T (2003) Mortality in a population-based cohort of epilepsy surgery patients. Epilepsia 44:575–581PubMedCrossRef
29.
go back to reference Onal C, Otsubo H, Araki T, Chitoku S, Ochi A, Weiss S, Elliott I, Snead OC 3rd, Rutka JT, Logan W (2003) Complications of invasive subdural grid monitoring in children with epilepsy. J Neurosurg 98:1017–1026PubMed Onal C, Otsubo H, Araki T, Chitoku S, Ochi A, Weiss S, Elliott I, Snead OC 3rd, Rutka JT, Logan W (2003) Complications of invasive subdural grid monitoring in children with epilepsy. J Neurosurg 98:1017–1026PubMed
30.
go back to reference Pilcher WH, Rusyniak WG (1993) Complications of epilepsy surgery. Neurosurg Clin N Am 4:311–325PubMed Pilcher WH, Rusyniak WG (1993) Complications of epilepsy surgery. Neurosurg Clin N Am 4:311–325PubMed
31.
go back to reference Rosenbaum TJ, Laxer KD, Vessely M, Smith WB (1986) Subdural electrodes for seizure focus localization. Neurosurgery 19:73–81PubMedCrossRef Rosenbaum TJ, Laxer KD, Vessely M, Smith WB (1986) Subdural electrodes for seizure focus localization. Neurosurgery 19:73–81PubMedCrossRef
33.
go back to reference Rydenhag B, Silander HC (2001) Complications of epilepsy surgery after 654 procedures in Sweden, September 1990-1995: a multicenter study based on the Swedish National Epilepsy Surgery Register. Neurosurgery 49:51–56PubMedCrossRef Rydenhag B, Silander HC (2001) Complications of epilepsy surgery after 654 procedures in Sweden, September 1990-1995: a multicenter study based on the Swedish National Epilepsy Surgery Register. Neurosurgery 49:51–56PubMedCrossRef
34.
go back to reference Shah AK, Fuerst D, Sood S, Asano E, Ahn-Ewing J, Pawlak C, Chugani HT (2007) Seizures lead to elevation of intracranial pressure in children undergoing invasive EEG monitoring. Epilepsia 48:1097–1103PubMedCrossRef Shah AK, Fuerst D, Sood S, Asano E, Ahn-Ewing J, Pawlak C, Chugani HT (2007) Seizures lead to elevation of intracranial pressure in children undergoing invasive EEG monitoring. Epilepsia 48:1097–1103PubMedCrossRef
35.
go back to reference Silberbusch MA, Rothman MI, Bergey GK, Zoarski GH, Zagardo MT (1998) Subdural grid implantation for intracranial EEG recording: CT and MR appearance. AJNR: Am J Neuroradiol 19:1089–1093PubMed Silberbusch MA, Rothman MI, Bergey GK, Zoarski GH, Zagardo MT (1998) Subdural grid implantation for intracranial EEG recording: CT and MR appearance. AJNR: Am J Neuroradiol 19:1089–1093PubMed
36.
go back to reference Son YJ, Chung CK, Lee SK, Chang KH, Lee DS, Yi YN, Kim HJ (1999) Comparison of localizing values of various diagnostic tests in non-lesional medial temporal lobe epilepsy. Seizure 8:465–470PubMedCrossRef Son YJ, Chung CK, Lee SK, Chang KH, Lee DS, Yi YN, Kim HJ (1999) Comparison of localizing values of various diagnostic tests in non-lesional medial temporal lobe epilepsy. Seizure 8:465–470PubMedCrossRef
37.
go back to reference Stephan CL, Kepes JJ, SantaCruz K, Wilkinson SB, Fegley B, Osorio I (2001) Spectrum of clinical and histopathologic responses to intracranial electrodes: from multifocal aseptic meningitis to multifocal hypersensitivity-type meningovasculitis. Epilepsia 42:895–901PubMedCrossRef Stephan CL, Kepes JJ, SantaCruz K, Wilkinson SB, Fegley B, Osorio I (2001) Spectrum of clinical and histopathologic responses to intracranial electrodes: from multifocal aseptic meningitis to multifocal hypersensitivity-type meningovasculitis. Epilepsia 42:895–901PubMedCrossRef
38.
go back to reference Umemura A, Jaggi JL, Hurtig HI, Siderowf AD, Colcher A, Stern MB, Baltuch GH (2003) Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients. J Neurosurg 98:779–784PubMedCrossRef Umemura A, Jaggi JL, Hurtig HI, Siderowf AD, Colcher A, Stern MB, Baltuch GH (2003) Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients. J Neurosurg 98:779–784PubMedCrossRef
39.
go back to reference Ween JE, Alexander MP, D’Esposito M, Roberts M (1996) Factors predictive of stroke outcome in a rehabilitation setting. Neurology 47:388–392PubMed Ween JE, Alexander MP, D’Esposito M, Roberts M (1996) Factors predictive of stroke outcome in a rehabilitation setting. Neurology 47:388–392PubMed
40.
go back to reference Wiggins GC, Elisevich K, Smith BJ (1999) Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy. Epilepsy Res 37:73–80PubMedCrossRef Wiggins GC, Elisevich K, Smith BJ (1999) Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy. Epilepsy Res 37:73–80PubMedCrossRef
41.
go back to reference Wyler AR, Ojemann GA, Lettich E, Ward AA Jr (1984) Subdural strip electrodes for localizing epileptogenic foci. J Neurosurg 60:1195–1200PubMed Wyler AR, Ojemann GA, Lettich E, Ward AA Jr (1984) Subdural strip electrodes for localizing epileptogenic foci. J Neurosurg 60:1195–1200PubMed
42.
go back to reference Wyler AR, Walker G, Somes G (1991) The morbidity of long-term seizure monitoring using subdural strip electrodes. J Neurosurg 74:734–737PubMed Wyler AR, Walker G, Somes G (1991) The morbidity of long-term seizure monitoring using subdural strip electrodes. J Neurosurg 74:734–737PubMed
43.
go back to reference Zaccariotti VA, Pannek HW, Holthausen H, Oppel F (1999) Evaluation with subdural plates in children and adolescents. Neurol Res 21:463–474PubMed Zaccariotti VA, Pannek HW, Holthausen H, Oppel F (1999) Evaluation with subdural plates in children and adolescents. Neurol Res 21:463–474PubMed
Metadata
Title
Risk factors for complications during intracranial electrode recording in presurgical evaluation of drug resistant partial epilepsy
Authors
Chong H. Wong
Julie Birkett
Karen Byth
Mark Dexter
Ernest Somerville
Deepak Gill
Ray Chaseling
Michael Fearnside
Andrew Bleasel
Publication date
01-01-2009
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 1/2009
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-008-0171-7

Other articles of this Issue 1/2009

Acta Neurochirurgica 1/2009 Go to the issue