Published in: Netherlands Heart Journal 3/2013

01-03-2013 | Editorial Comment

Riata type implantable cardiac defibrillator leads: increasingly small, progressively troublesome

Authors: A. Elvan, A. Adiyaman

Published in: Netherlands Heart Journal | Issue 3/2013

Login to get access

Excerpt

Already in 1970, Mirowski and colleagues worked on the development of the first implantable cardiac defibrillator (ICD). Since then, important progression has been made by increasingly complex pacing and defibrillation functions, higher battery durability, and reduction of both device and shock lead size. A large amount of evidence has shown that ICDs are life-saving and cost-effective, both for primary and secondary prevention of sudden arrhythmic cardiac death. In the last decade, a quest for smaller shock lead design was initiated, but unfortunately increasing dysfunction rates of ICD generators and leads were to be unmasked only a few years later.[1, 2] Medtronic’s 6.7 Fr Sprint Fidelis lead was recalled by the FDA in 2007 and St. Jude’s 7.6 Fr Riata and 6.3 Riata ST leads were recalled by the manufacturer, FDA and the Dutch authorities in 2011. By then, the vast amount of approximately 227,000 Riata leads, and 268,000 Sprint Fidelis leads had been distributed worldwide. …
Literature
1.
go back to reference Beukema RJ, Ramdat Misier AR, Delnoy PP, et al. Characteristics of sprint fidelis lead failure. Neth Heart J. 2010;18:12–7.PubMed Beukema RJ, Ramdat Misier AR, Delnoy PP, et al. Characteristics of sprint fidelis lead failure. Neth Heart J. 2010;18:12–7.PubMed
2.
go back to reference Shein MJ, Moynahan M. FDA viewpoint: St. Jude Medical’s Riata ST leads. Pacing Clin Electrophysiol. 2008;31:16.PubMedCrossRef Shein MJ, Moynahan M. FDA viewpoint: St. Jude Medical’s Riata ST leads. Pacing Clin Electrophysiol. 2008;31:16.PubMedCrossRef
5.
go back to reference Hauser RG, Abdelhadi R, McGriff D, et al. Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Hear Rhythm. 2012;9:1227–35.CrossRef Hauser RG, Abdelhadi R, McGriff D, et al. Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads. Hear Rhythm. 2012;9:1227–35.CrossRef
Metadata
Title
Riata type implantable cardiac defibrillator leads: increasingly small, progressively troublesome
Authors
A. Elvan
A. Adiyaman
Publication date
01-03-2013
Publisher
Bohn Stafleu van Loghum
Published in
Netherlands Heart Journal / Issue 3/2013
Print ISSN: 1568-5888
Electronic ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-013-0377-z

Other articles of this Issue 3/2013

Netherlands Heart Journal 3/2013 Go to the issue

Rhythm Puzzle - Questions

Palpitations, should one worry?