Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 5/2008

01-06-2008 | Original Paper

Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

Authors: Dae-Weung Kim, Soon-Ah Park, Chang-Guhn Kim, Cheol Lee, Seok Kyu Oh, Jin-Won Jeong

Published in: The International Journal of Cardiovascular Imaging | Issue 5/2008

Login to get access

Abstract

Purpose If coronary artery was treated with optimal stent implantation, myocardial perfusion in the territory supplied by a dilated coronary artery should be not reversible. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Methods About 66 patients that underwent M-SPECT within 24 h of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Results Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis.
Literature
1.
go back to reference Wijns W, Serruys PW, Reiber JH et al (1985) Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution thallium scintigraphy. Am J Cardiol 55:357–361PubMedCrossRef Wijns W, Serruys PW, Reiber JH et al (1985) Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution thallium scintigraphy. Am J Cardiol 55:357–361PubMedCrossRef
2.
go back to reference Jain A, Mahmarian JJ, Borges-Neto S et al (1988) Clinical significance of perfusion defects by thallium-201 single photon emission tomography following oral dipyridamole early after coronary angioplasty. J Am Coll Cardiol 11:970–976PubMed Jain A, Mahmarian JJ, Borges-Neto S et al (1988) Clinical significance of perfusion defects by thallium-201 single photon emission tomography following oral dipyridamole early after coronary angioplasty. J Am Coll Cardiol 11:970–976PubMed
3.
go back to reference Hardoff R, Shefer A, Gips S et al (1990) Predicting late restenosis after coronary angioplasty by very early (12–24 h) thallium-201 scintigraphy: implications with regard to mechanisms of late coronary restenosis. J Am Coll Cardiol 15:1486–1492PubMed Hardoff R, Shefer A, Gips S et al (1990) Predicting late restenosis after coronary angioplasty by very early (12–24 h) thallium-201 scintigraphy: implications with regard to mechanisms of late coronary restenosis. J Am Coll Cardiol 15:1486–1492PubMed
4.
go back to reference Bachmann R, Sechtem U, Voth E et al (1997) Dipyridamole scintigraphy and intravascular ultrasound after successful coronary intervention. J Nucl Med 38:553–558PubMed Bachmann R, Sechtem U, Voth E et al (1997) Dipyridamole scintigraphy and intravascular ultrasound after successful coronary intervention. J Nucl Med 38:553–558PubMed
5.
go back to reference Holmes D (1990) Very early prediction of restenosis after successful coronary angioplasty: how early is early and can we identify it? J Am Coll Cardiol 15:265–266PubMed Holmes D (1990) Very early prediction of restenosis after successful coronary angioplasty: how early is early and can we identify it? J Am Coll Cardiol 15:265–266PubMed
6.
go back to reference Serruys PW, de Jaegere P, Kiemeneij F et al (1994) A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 331:489–495PubMedCrossRef Serruys PW, de Jaegere P, Kiemeneij F et al (1994) A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 331:489–495PubMedCrossRef
7.
go back to reference Fischman DL, Leon MB, Baim DS et al (1994) A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 331:496–501PubMedCrossRef Fischman DL, Leon MB, Baim DS et al (1994) A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 331:496–501PubMedCrossRef
8.
go back to reference Rodes-Cabua J, Candell-Riera J, Domingo E et al (2001) Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation. J Nucl Med 42:1768–1772 Rodes-Cabua J, Candell-Riera J, Domingo E et al (2001) Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation. J Nucl Med 42:1768–1772
9.
go back to reference Jaffe R, Haim SB, Karkabi B et al (2002) Myocardial perfusion abnormalities early (12–24h) after coronary stenting or balloon angioplasty: implications regarding pathophysiology and late clinical outcome. Cardiology 98:60–66PubMedCrossRef Jaffe R, Haim SB, Karkabi B et al (2002) Myocardial perfusion abnormalities early (12–24h) after coronary stenting or balloon angioplasty: implications regarding pathophysiology and late clinical outcome. Cardiology 98:60–66PubMedCrossRef
10.
go back to reference Nagaoka H, Iizuka T, Kubota S et al (1998) Redistribution in thallium-201 myocardial imaging soon after successful coronary stenting: tomographic evaluation during coronary hyperemia induced by adenosine. Jpn Circ J 62:160–166PubMedCrossRef Nagaoka H, Iizuka T, Kubota S et al (1998) Redistribution in thallium-201 myocardial imaging soon after successful coronary stenting: tomographic evaluation during coronary hyperemia induced by adenosine. Jpn Circ J 62:160–166PubMedCrossRef
11.
go back to reference Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Circulation 51:5–40PubMed Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Circulation 51:5–40PubMed
12.
go back to reference Emmett L, Iwanochko RM, Freeman MR et al (2002) Reversible regional wall motion abnormalities on exercise technetium-99m-gated cardiac single photon emission computed tomography predict high-grade angiographic stenoses. J Am Coll Cardiol 39:991–998PubMedCrossRef Emmett L, Iwanochko RM, Freeman MR et al (2002) Reversible regional wall motion abnormalities on exercise technetium-99m-gated cardiac single photon emission computed tomography predict high-grade angiographic stenoses. J Am Coll Cardiol 39:991–998PubMedCrossRef
13.
go back to reference Caramore PRA, Lima VC, Seidelin PH et al (1999) Long-term endothelial dysfunction after coronary artery stenting. J Am Coll Cardiol 34:1675–1679CrossRef Caramore PRA, Lima VC, Seidelin PH et al (1999) Long-term endothelial dysfunction after coronary artery stenting. J Am Coll Cardiol 34:1675–1679CrossRef
14.
go back to reference Kern MJ, Puri S, Bach RG et al (1999) Abnormal coronary flow velocity reserve after coronary artery stenting in patients. Circulation 100:2491–2498PubMed Kern MJ, Puri S, Bach RG et al (1999) Abnormal coronary flow velocity reserve after coronary artery stenting in patients. Circulation 100:2491–2498PubMed
15.
go back to reference Leosco D, Fineschi M, Pierli C et al (1999) Intracoronary serotonin release after high-pressure coronary stenting. Am J Cardiol 84:1317–1322PubMedCrossRef Leosco D, Fineschi M, Pierli C et al (1999) Intracoronary serotonin release after high-pressure coronary stenting. Am J Cardiol 84:1317–1322PubMedCrossRef
16.
go back to reference van Beusekom HM, Whelan DM, Hofma SH et al (1998) Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. J Am Coll Cardiol 32:1109–1117PubMedCrossRef van Beusekom HM, Whelan DM, Hofma SH et al (1998) Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. J Am Coll Cardiol 32:1109–1117PubMedCrossRef
17.
go back to reference Marx R, Jax T, Schannwell CM et al (2006) Disturbed endothelial function of the internal thoracic artery in patients with coronary artery disease. Int J Cardiovasc Imaging 22:755–762PubMedCrossRef Marx R, Jax T, Schannwell CM et al (2006) Disturbed endothelial function of the internal thoracic artery in patients with coronary artery disease. Int J Cardiovasc Imaging 22:755–762PubMedCrossRef
18.
go back to reference Giedd KN, Bergmann SR (2004) Myocardial perfusion imaging following percutaneous coronary intervention: the importance of restenosis, disease progression, and directed reintervention. J Am Coll Cardiol 43:328–336PubMedCrossRef Giedd KN, Bergmann SR (2004) Myocardial perfusion imaging following percutaneous coronary intervention: the importance of restenosis, disease progression, and directed reintervention. J Am Coll Cardiol 43:328–336PubMedCrossRef
19.
go back to reference DePuey EG (1991) Myocardial perfusion imaging with thallium-201 to evaluate patients before and after percutaneous transluminal coronary angioplasty. Circulation 84:159–165 DePuey EG (1991) Myocardial perfusion imaging with thallium-201 to evaluate patients before and after percutaneous transluminal coronary angioplasty. Circulation 84:159–165
20.
go back to reference Wilson RF, Johnson MR, Marcus ML et al (1988) The effect of coronary angioplasty on coronary flow reserve. Circulation 77:873–885PubMed Wilson RF, Johnson MR, Marcus ML et al (1988) The effect of coronary angioplasty on coronary flow reserve. Circulation 77:873–885PubMed
21.
go back to reference Uren NG, Crake T, Lefroy DC et al (1993) Delayed recovery of coronary resistive vessel function after coronary angioplasty. J Am Coll Cardiol 21:612–621PubMedCrossRef Uren NG, Crake T, Lefroy DC et al (1993) Delayed recovery of coronary resistive vessel function after coronary angioplasty. J Am Coll Cardiol 21:612–621PubMedCrossRef
22.
go back to reference Versaci F, Tomai F, Nudi F et al (1996) Differences of regional coronary flow reserve assessed by adenosine thallium-201 scintigraphy early and six months after successful percutaneous transluminal coronary angioplasty or stent implantation. Am J Cardiol 78:1097–1102PubMedCrossRef Versaci F, Tomai F, Nudi F et al (1996) Differences of regional coronary flow reserve assessed by adenosine thallium-201 scintigraphy early and six months after successful percutaneous transluminal coronary angioplasty or stent implantation. Am J Cardiol 78:1097–1102PubMedCrossRef
23.
go back to reference Lewis BS, Hardoff R, Merdler A et al (1995) Importance of immediate and very early postprocedural angiographic and thallium-201 single photon emission computed tomographic perfusion measurements in predicting late results after coronary intervention. Am Heart J 130:425–432PubMedCrossRef Lewis BS, Hardoff R, Merdler A et al (1995) Importance of immediate and very early postprocedural angiographic and thallium-201 single photon emission computed tomographic perfusion measurements in predicting late results after coronary intervention. Am Heart J 130:425–432PubMedCrossRef
24.
go back to reference Samuels B, Schummann J, Kiat H et al (1995) Acute stent thrombosis associated with exercise testing after successful percutaneous transluminal coronary angioplasty. Am Heart J 130:1120–1122PubMedCrossRef Samuels B, Schummann J, Kiat H et al (1995) Acute stent thrombosis associated with exercise testing after successful percutaneous transluminal coronary angioplasty. Am Heart J 130:1120–1122PubMedCrossRef
25.
go back to reference Meurin P, Domniez T, Weber H et al (1999) Occlusion of a coronary endoprosthesis after a negative stress test. Arch Mal Coeur Vaiss 92:369–372PubMed Meurin P, Domniez T, Weber H et al (1999) Occlusion of a coronary endoprosthesis after a negative stress test. Arch Mal Coeur Vaiss 92:369–372PubMed
26.
go back to reference Roffi M, Wenaweser P, Windecker S et al (2003) Early exercise after coronary stenting is safe. J Am Coll Cardiol 42:1569–1573PubMedCrossRef Roffi M, Wenaweser P, Windecker S et al (2003) Early exercise after coronary stenting is safe. J Am Coll Cardiol 42:1569–1573PubMedCrossRef
27.
go back to reference Kulhanek J, Sorrell VL, Ershadi RE et al (2002) Adenosine myocardial perfusion single photon emission computed tomographic stress testing 24–72 h after uncomplicated myocardial infarction. Int J Cardiovasc Imaging 18:269–272PubMedCrossRef Kulhanek J, Sorrell VL, Ershadi RE et al (2002) Adenosine myocardial perfusion single photon emission computed tomographic stress testing 24–72 h after uncomplicated myocardial infarction. Int J Cardiovasc Imaging 18:269–272PubMedCrossRef
28.
go back to reference Bauters C, Hubert E, Prat A et al (1998) Predictors of restenosis after coronary stent implantation. J Am Coll Cardiol 31:1291–1298PubMedCrossRef Bauters C, Hubert E, Prat A et al (1998) Predictors of restenosis after coronary stent implantation. J Am Coll Cardiol 31:1291–1298PubMedCrossRef
29.
go back to reference Berger PB, Bell MR, Grill DE et al (1998) Frequency of adverse clinical events in the 12 months following successful intracoronary stent placement in patients treated with aspirin and ticlopidine (without warfarin). Am J Cardiol 81:713–718PubMedCrossRef Berger PB, Bell MR, Grill DE et al (1998) Frequency of adverse clinical events in the 12 months following successful intracoronary stent placement in patients treated with aspirin and ticlopidine (without warfarin). Am J Cardiol 81:713–718PubMedCrossRef
Metadata
Title
Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis
Authors
Dae-Weung Kim
Soon-Ah Park
Chang-Guhn Kim
Cheol Lee
Seok Kyu Oh
Jin-Won Jeong
Publication date
01-06-2008
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 5/2008
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-007-9273-1

Other articles of this Issue 5/2008

The International Journal of Cardiovascular Imaging 5/2008 Go to the issue