Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Research

Retention of hybrid-abutment-crowns with offset implant placement: influence of Crown materials and Ti-base height

Authors: Ahmed Alseddiek, Walid Al-Zordk, Ahmed Attia

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

The purpose of the current study was to assess the impact of three esthetic CAD/CAM material, titanium base height and their interaction on the retention strength of a hybrid-abutment-crown.

Methods

A total of 42 hybrid-abutment crowns with identical external geometries were designed in CAD software to fit two different Ti-Base abutment heights (n = 42/abutment height): either short (S) with 4 mm (n = 21) or long (L) 7 mm (n = 21) height. Each main group was divided into 3 subgroups (n = 7), according to esthetic crown material, Zirconia (Z), Lithium disilicate (L) and Hybrid ceramic (V). A universal primer and an adhesive resin cement were used for bonding according to the manufacturer instructions. Artificial aging in form of water storage (30 days), chewing simulation (50,000-cycles, 49 N, 1.67 Hz) and thermal cyclic (5000 cycles at 5–55 °C) were applied, specimens were pulled-out under tension load in (N) using a universal testing machine. Two and one-way ANOVA and Post Hoc Tukey test were used for statistical analysis.

Results

Long lithium disilicate (LL) group showed the highest retention (738.7 ± 178.5) followed by short lithium disilicate (LS) group (688.6 ± 169.9). Meanwhile, short zirconia (ZS) showed the lowest retention strength (231.1 ± 86.9).

Conclusion

CAD/CAM fabricated lithium disilicate hybrid-abutment-crown can be used instead of conventional crowns over implant abutment. Etchable ceramics are recommended as a material of choice for CAD/CAM fabricated hybrid-abutment-crowns instead of zirconia in terms of retention durability.
Literature
1.
go back to reference Jung RE, Zembic A, Pjetursson BE, Zwahlen M, ThomaDS. Systematic review of the survival rate and the incidenceof biological, technical, and esthetic compilcations ofsingle crowns on implans reported in longitudinal studieswith a mean follow-up of 5 years. Clin Oral Implant Res. 2012;23:2–21.CrossRef Jung RE, Zembic A, Pjetursson BE, Zwahlen M, ThomaDS. Systematic review of the survival rate and the incidenceof biological, technical, and esthetic compilcations ofsingle crowns on implans reported in longitudinal studieswith a mean follow-up of 5 years. Clin Oral Implant Res. 2012;23:2–21.CrossRef
2.
go back to reference De Angelis P, Passarelli PC, Gasparini G, Boniello R, D’Amato G, De Angelis S. Monolithic CAD-CAM lithium disilicate versus monolithic CAD-CAM zirconia for single implant-supported posterior crowns using a digital workflow: a 3-year cross-sectional retrospective study. J Prosthet Dent. 2020;123:252–6.CrossRefPubMed De Angelis P, Passarelli PC, Gasparini G, Boniello R, D’Amato G, De Angelis S. Monolithic CAD-CAM lithium disilicate versus monolithic CAD-CAM zirconia for single implant-supported posterior crowns using a digital workflow: a 3-year cross-sectional retrospective study. J Prosthet Dent. 2020;123:252–6.CrossRefPubMed
3.
go back to reference Edelhoff D, Sorensen JA. Tooth structure removal associated with various preparation designs for posterior teeth. Int J Periodontics Restorative Dent., Oliveira D, Pereira JC, Gomes-Ferreira PHS, Kottwitz AB. Prosthetic resolution of malpositioned dental implants with5-year follow-up. Edelhoff D, Sorensen JA. Tooth structure removal associated with various preparation designs for posterior teeth. Int J Periodontics Restorative Dent., Oliveira D, Pereira JC, Gomes-Ferreira PHS, Kottwitz AB. Prosthetic resolution of malpositioned dental implants with5-year follow-up.
4.
go back to reference Oliveira D, Pereira JC, Gomes-Ferreira PHS, Kottwitz AB. Prosthetic resolution of malpositioned dental implants with 5-year follow-up. Oliveira D, Pereira JC, Gomes-Ferreira PHS, Kottwitz AB. Prosthetic resolution of malpositioned dental implants with 5-year follow-up.
5.
go back to reference Chung H, Park C, Yun K-D, Lim H-P, Park S-W, Yang H. Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis. J Dent Rehabil Appl Sci. 2020;36:176–82.CrossRef Chung H, Park C, Yun K-D, Lim H-P, Park S-W, Yang H. Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis. J Dent Rehabil Appl Sci. 2020;36:176–82.CrossRef
6.
go back to reference Tribst JPM, Piva AMDOD, Borges ALS, Bottino MA. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis. Revista de Odontologia da UNESP. 2018;47(3):149–54.CrossRef Tribst JPM, Piva AMDOD, Borges ALS, Bottino MA. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis. Revista de Odontologia da UNESP. 2018;47(3):149–54.CrossRef
7.
go back to reference Maló P, De Arauja Nobre M, Lopes A, Ferro A. GravitoI. Single tooth rehabilitation supported by dental implantsused in an immediate provisionalization protocol: reporton long term outcome with retrospective follow-up. Clin Implant Dent Relat Res. 2015;17:511–9.CrossRef Maló P, De Arauja Nobre M, Lopes A, Ferro A. GravitoI. Single tooth rehabilitation supported by dental implantsused in an immediate provisionalization protocol: reporton long term outcome with retrospective follow-up. Clin Implant Dent Relat Res. 2015;17:511–9.CrossRef
8.
go back to reference Zarauz C. Clinical recommendations for implant abutment selection for single-implant reconstructions: customized vs standardized ceramic and metallic solutions. Int J Periodontics Restorative Dent. 2020;40:31–7.CrossRefPubMed Zarauz C. Clinical recommendations for implant abutment selection for single-implant reconstructions: customized vs standardized ceramic and metallic solutions. Int J Periodontics Restorative Dent. 2020;40:31–7.CrossRefPubMed
9.
go back to reference Korsch M, Walther W. Prefabricated Versus customized abutments: a retrospective analysis of loosening of cement-retained fixed Implant-Supported Reconstructions. Int J Prosthodont. 2015;28:522–6.CrossRefPubMed Korsch M, Walther W. Prefabricated Versus customized abutments: a retrospective analysis of loosening of cement-retained fixed Implant-Supported Reconstructions. Int J Prosthodont. 2015;28:522–6.CrossRefPubMed
10.
go back to reference Abichandani SJ, Nadiger R, Kavlekar AS. Abutment selection, designing, and its influence on the emergence profile: a comprehensive review. Eur J Prosthodont. 2013;1(1):1.CrossRef Abichandani SJ, Nadiger R, Kavlekar AS. Abutment selection, designing, and its influence on the emergence profile: a comprehensive review. Eur J Prosthodont. 2013;1(1):1.CrossRef
11.
go back to reference Turkoglu P, Kose A, Sen D. Abutment selection for anterior implant-supported restorations. An Update on Dental Implantology and Biomaterial. 2019:61. Turkoglu P, Kose A, Sen D. Abutment selection for anterior implant-supported restorations. An Update on Dental Implantology and Biomaterial. 2019:61.
12.
go back to reference Martinez-Rus F, Ferreiroa A, Özcan M, Bartolomé JF, Pradies G. Fracture resistance of crowns cemented ontitanium and zirconia implant abutments: a comparison omonolithic versus manually veneered all-ceramic systems. Int J Oral Maxillofac Implants. 2012;27:1448–55.PubMed Martinez-Rus F, Ferreiroa A, Özcan M, Bartolomé JF, Pradies G. Fracture resistance of crowns cemented ontitanium and zirconia implant abutments: a comparison omonolithic versus manually veneered all-ceramic systems. Int J Oral Maxillofac Implants. 2012;27:1448–55.PubMed
13.
go back to reference Nouh I, Kern M, Sabet AE, Aboelfadl AK, Hamdy AM, Chaar MS. Mechanical behavior of posterior all-ceramic hybrid‐abutment‐crowns versus hybrid‐abutments with separate crowns—A laboratory study. Clin Oral Implants Res. 2019;30:90–8.CrossRefPubMed Nouh I, Kern M, Sabet AE, Aboelfadl AK, Hamdy AM, Chaar MS. Mechanical behavior of posterior all-ceramic hybrid‐abutment‐crowns versus hybrid‐abutments with separate crowns—A laboratory study. Clin Oral Implants Res. 2019;30:90–8.CrossRefPubMed
14.
go back to reference Mangano F, Margiani B, Admakin O. A novel full-digital protocol (SCAN-PLAN-MAKE-DONE®) for the design and fabrication of implant-supported monolithic translucent zirconia crowns cemented on customized hybrid abutments: a retrospective clinical study on 25 patients. Int J Environ Res Public Health. 2019;16:317.CrossRefPubMedPubMedCentral Mangano F, Margiani B, Admakin O. A novel full-digital protocol (SCAN-PLAN-MAKE-DONE®) for the design and fabrication of implant-supported monolithic translucent zirconia crowns cemented on customized hybrid abutments: a retrospective clinical study on 25 patients. Int J Environ Res Public Health. 2019;16:317.CrossRefPubMedPubMedCentral
15.
go back to reference Pitta J, Hicklin SP, Fehmer V, Boldt J, Gierthmuehlen PC, Sailer I. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns. Int J Oral Maxillofac Implants. 2019;34:1091–7.CrossRefPubMed Pitta J, Hicklin SP, Fehmer V, Boldt J, Gierthmuehlen PC, Sailer I. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns. Int J Oral Maxillofac Implants. 2019;34:1091–7.CrossRefPubMed
16.
go back to reference Mehl C, Zhang Q, Lehmann F, Kern M. Retention of zirconia on titanium in two-piece abutments with self-adhesive resin cement. J Prosthet Dent. 2018;120:214–9.CrossRefPubMed Mehl C, Zhang Q, Lehmann F, Kern M. Retention of zirconia on titanium in two-piece abutments with self-adhesive resin cement. J Prosthet Dent. 2018;120:214–9.CrossRefPubMed
17.
go back to reference Kemarly K, Arnason SC, Parke A, Lien W, Vandewalle KS. Effect of various surface treatments on Ti-Base Coping Retention. Oper Dent. 2020;45:426–34.CrossRefPubMed Kemarly K, Arnason SC, Parke A, Lien W, Vandewalle KS. Effect of various surface treatments on Ti-Base Coping Retention. Oper Dent. 2020;45:426–34.CrossRefPubMed
18.
go back to reference Alqahtani F, Flinton R. Post-fatigue fracture resistance of modified prefabricated zirconia implant abutments. J Prosthet Dent. 2014;112:299–305.CrossRefPubMed Alqahtani F, Flinton R. Post-fatigue fracture resistance of modified prefabricated zirconia implant abutments. J Prosthet Dent. 2014;112:299–305.CrossRefPubMed
19.
go back to reference Stimmelmayr M, Edelhoff D, Güth JF, Erdelt K, Happe A, Beuer F. Wear at the titanium-titanium and the titanium-zirconia implant abutment interface: a comparative invitro study. Dent Mater. 2012;28:1215–20.CrossRefPubMed Stimmelmayr M, Edelhoff D, Güth JF, Erdelt K, Happe A, Beuer F. Wear at the titanium-titanium and the titanium-zirconia implant abutment interface: a comparative invitro study. Dent Mater. 2012;28:1215–20.CrossRefPubMed
20.
go back to reference Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater. 2013;29:419–26.CrossRefPubMed Coldea A, Swain MV, Thiel N. Mechanical properties of polymer-infiltrated-ceramic-network materials. Dent Mater. 2013;29:419–26.CrossRefPubMed
21.
22.
go back to reference Zahoui A, Bergamo ET, Marun MM, Silva KP, Coelho PG, Bonfante EA. Cementation Protocol for Bonding Zirconia Crowns to Titanium Base CAD/CAM abutments. Int J Prosthodont. 2020;33:527–35.CrossRefPubMed Zahoui A, Bergamo ET, Marun MM, Silva KP, Coelho PG, Bonfante EA. Cementation Protocol for Bonding Zirconia Crowns to Titanium Base CAD/CAM abutments. Int J Prosthodont. 2020;33:527–35.CrossRefPubMed
23.
go back to reference Silva CE, Soares S, Machado CM, et al. Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns. Implant Dent. 2018;27:582–7.CrossRefPubMed Silva CE, Soares S, Machado CM, et al. Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns. Implant Dent. 2018;27:582–7.CrossRefPubMed
24.
go back to reference Bernal G, Okamura M, Munoz CA. The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations. J Prosthodont. 2003;12:111–5.CrossRefPubMed Bernal G, Okamura M, Munoz CA. The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations. J Prosthodont. 2003;12:111–5.CrossRefPubMed
25.
go back to reference Blatz MB, Alvarez M, Sawyer K, Brindis M. How to Bond Zirconia: the APC Concept. Compend Contin Educ Dent. 2016;37:611–8.PubMed Blatz MB, Alvarez M, Sawyer K, Brindis M. How to Bond Zirconia: the APC Concept. Compend Contin Educ Dent. 2016;37:611–8.PubMed
26.
go back to reference Campos F, Almeida CS, Rippe MP, de Melo RM, Valandro LF, Bottino MA. Resin Bonding to a hybrid ceramic: Effects of Surface Treatments and Aging. Oper Dent. 2016;41:171–8.CrossRefPubMed Campos F, Almeida CS, Rippe MP, de Melo RM, Valandro LF, Bottino MA. Resin Bonding to a hybrid ceramic: Effects of Surface Treatments and Aging. Oper Dent. 2016;41:171–8.CrossRefPubMed
27.
go back to reference Peumans M, Valjakova EB, De Munck J, Mishevska CB, Van Meerbeek B. Bonding effectiveness of luting composites to different CAD/CAM materials. J Adhes Dent. 2016;18:289–302.PubMed Peumans M, Valjakova EB, De Munck J, Mishevska CB, Van Meerbeek B. Bonding effectiveness of luting composites to different CAD/CAM materials. J Adhes Dent. 2016;18:289–302.PubMed
28.
go back to reference Pitta J, Burkhardt F, Mekki M, Fehmer V, Mojon P, Sailer I. Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging. J Prosthet Dent. 2021;126:214–21.CrossRefPubMed Pitta J, Burkhardt F, Mekki M, Fehmer V, Mojon P, Sailer I. Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging. J Prosthet Dent. 2021;126:214–21.CrossRefPubMed
29.
go back to reference Chieffi N, Chersoni S, Papacchini F, Vano M, Goracci C, Davidson CL, et al. The effect of application sustained seating pressure on adhesive luting procedure. Dent Mater. 2007;23:159–64.CrossRefPubMed Chieffi N, Chersoni S, Papacchini F, Vano M, Goracci C, Davidson CL, et al. The effect of application sustained seating pressure on adhesive luting procedure. Dent Mater. 2007;23:159–64.CrossRefPubMed
30.
go back to reference Chieffi N, Chersoni S, Papacchini F, Vano M, Goracci C, Davidson CL, et al. Effect of the seating pressure on the adhesive bonding of indirect restorations. Am J Dent. 2006;19:333–6.PubMed Chieffi N, Chersoni S, Papacchini F, Vano M, Goracci C, Davidson CL, et al. Effect of the seating pressure on the adhesive bonding of indirect restorations. Am J Dent. 2006;19:333–6.PubMed
31.
go back to reference Steiner M, Mitsias ME, Ludwig K, Kern M. In vitro evaluation of a mechanical testing chewing simulator. Dent Mater. 2009;25:494–9.CrossRefPubMed Steiner M, Mitsias ME, Ludwig K, Kern M. In vitro evaluation of a mechanical testing chewing simulator. Dent Mater. 2009;25:494–9.CrossRefPubMed
32.
go back to reference Silva CEP, Soares S, Machado CM, et al. Effect of CAD/CAM abutment height and cement type on the Retention of Zirconia crowns. Implant Dent. 2018;27:582–7.CrossRefPubMed Silva CEP, Soares S, Machado CM, et al. Effect of CAD/CAM abutment height and cement type on the Retention of Zirconia crowns. Implant Dent. 2018;27:582–7.CrossRefPubMed
33.
go back to reference Abbo B, Razzoog ME, Vivas J, Sierraalta M. Resistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights. J Prosthet Dent. 2008;99:25–9.CrossRefPubMed Abbo B, Razzoog ME, Vivas J, Sierraalta M. Resistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights. J Prosthet Dent. 2008;99:25–9.CrossRefPubMed
34.
go back to reference Dhesi GS, Sidhu S, Al-Haj Husain N, Özcan M. Evaluation of Adhesion Protocol for Titanium Base Abutments to different ceramic and hybrid materials. Eur J Prosthodont Restor Dent. 2021;29:22–34.PubMed Dhesi GS, Sidhu S, Al-Haj Husain N, Özcan M. Evaluation of Adhesion Protocol for Titanium Base Abutments to different ceramic and hybrid materials. Eur J Prosthodont Restor Dent. 2021;29:22–34.PubMed
35.
go back to reference Elashmawy Y, Aboushelib M, Elshahawy W. Retention of different CAD/CAM endocrowns bonded to severely damaged endodontically treated teeth: an in vitro study. J Indian Prosthodont Soc. 2021 Jul-Sep;21(3):269–75. Elashmawy Y, Aboushelib M, Elshahawy W. Retention of different CAD/CAM endocrowns bonded to severely damaged endodontically treated teeth: an in vitro study. J Indian Prosthodont Soc. 2021 Jul-Sep;21(3):269–75.
36.
go back to reference Fayyazi A, Habibi L, Heidari B, Tavakolizadeh S. Tensile Bond Strength and Retention of three types of ceramic endocrowns. J Dent (Shiraz). 2023;24:34–40.PubMed Fayyazi A, Habibi L, Heidari B, Tavakolizadeh S. Tensile Bond Strength and Retention of three types of ceramic endocrowns. J Dent (Shiraz). 2023;24:34–40.PubMed
37.
go back to reference Bjelopavlovic M, Weyhrauch M, Scheller H, Wentaschek S, Lehmann KM. Retentive strength of CAD/CAM-Fabricated all-ceramic crowns luted on Titanium Implant Abutments using different ceramic materials and Luting Agents: an in Vitro Study. Mater (Basel). 2022;15:6968.ADSCrossRef Bjelopavlovic M, Weyhrauch M, Scheller H, Wentaschek S, Lehmann KM. Retentive strength of CAD/CAM-Fabricated all-ceramic crowns luted on Titanium Implant Abutments using different ceramic materials and Luting Agents: an in Vitro Study. Mater (Basel). 2022;15:6968.ADSCrossRef
38.
go back to reference Ongun S, Kurtulmus-Yilmaz S, Meriç G, Ulusoy M. A comparative study on the Mechanical Properties of a polymer-infiltrated ceramic-network material used for the fabrication of Hybrid Abutment. Mater (Basel). 2018;11:1681.ADSCrossRef Ongun S, Kurtulmus-Yilmaz S, Meriç G, Ulusoy M. A comparative study on the Mechanical Properties of a polymer-infiltrated ceramic-network material used for the fabrication of Hybrid Abutment. Mater (Basel). 2018;11:1681.ADSCrossRef
Metadata
Title
Retention of hybrid-abutment-crowns with offset implant placement: influence of Crown materials and Ti-base height
Authors
Ahmed Alseddiek
Walid Al-Zordk
Ahmed Attia
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03490-1

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue