Skip to main content
Top
Published in: BMC Anesthesiology 1/2018

Open Access 01-12-2018 | Research article

Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis

Authors: Bo Yao, Jian-yu Liu, Yun-bo Sun

Published in: BMC Anesthesiology | Issue 1/2018

Login to get access

Abstract

Background

Fluid overloading is detrimental to organ function and results in a poor prognosis. It is necessary to evaluate fluid responsiveness before fluid loading. We performed a systematic meta-analysis to evaluate the diagnostic value of the respiratory variation in peripheral arterial blood flow peak velocity (△Vpeak PA) in predicting fluid responsiveness in mechanically ventilated patients.

Methods

PubMed, Embase and The Cochrane Library databases were searched for studies that used △Vpeak PA to predict fluid responsiveness in mechanically ventilated patients. We calculated the pooled values of sensitivity, specificity and the area of the summary receiver operating characteristic curve by Meta-Disc 14.0 software.

Results

Nine studies with a total of 402 patients were included. Two low quality studies were deleted in further analysis. Moreover, because of different locations of peripheral artery, the rest included studies were divided into brachial site group and carotid site group for meta-analysis individually. The pooled sensitivity, specificity and area under curve were 0.85 (95% confidence interval (CI) 0.77–0.92), 0.86 (95% CI 0.77–0.92) and 0.9268 in carotid site group. The pooled sensitivity, specificity and area under curve were 0.72 (95% CI 0.60–0.81), 0.85 (95% CI 0.74–0.93) and 0.8587 in brachial site group.

Conclusions

△Vpeak of carotid and brachial artery had a diagnostic value in predicting fluid responsiveness respectively. Moreover, △Vpeak of carotid artery had more value than brachial artery in predicting fluid responsiveness. However, there was some clinical heterogeneity; therefore, further studies are needed to confirm diagnostic accuracy.
Literature
1.
go back to reference Kelm DJ, Perrin JT, Cartin-Ceba R, Gajic O, Schenck L, Kennedy CC. Fluid overload in patients with severe sepsis and septic shock treated with early goal-directed therapy is associated with increased acute need for fluid-related medical interventions and hospital death. Shock. 2015;43(1):68–73.CrossRef Kelm DJ, Perrin JT, Cartin-Ceba R, Gajic O, Schenck L, Kennedy CC. Fluid overload in patients with severe sepsis and septic shock treated with early goal-directed therapy is associated with increased acute need for fluid-related medical interventions and hospital death. Shock. 2015;43(1):68–73.CrossRef
2.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642–7.CrossRef Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642–7.CrossRef
3.
go back to reference Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1):172–8.CrossRef Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1):172–8.CrossRef
4.
go back to reference Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2008;35(1):64–8.CrossRef Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2008;35(1):64–8.CrossRef
6.
go back to reference Roehrig C, Govier M, Robinson J, Aneman A. Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery. Acta Anaesthesiol Scand. 2017;61(1):31–8.CrossRef Roehrig C, Govier M, Robinson J, Aneman A. Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery. Acta Anaesthesiol Scand. 2017;61(1):31–8.CrossRef
7.
go back to reference Brennan JM, Blair JE, Hampole C, et al. Radial artery pulse pressure variation correlates with brachial artery peak velocity variation in ventilated subjects when measured by internal medicine residents using hand-carried ultrasound devices. Chest. 2007;131(5):1301–7.CrossRef Brennan JM, Blair JE, Hampole C, et al. Radial artery pulse pressure variation correlates with brachial artery peak velocity variation in ventilated subjects when measured by internal medicine residents using hand-carried ultrasound devices. Chest. 2007;131(5):1301–7.CrossRef
8.
go back to reference Monge García MI, Gil Cano A, Díaz Monrové JC. Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care. 2009;13(5):R142.CrossRef Monge García MI, Gil Cano A, Díaz Monrové JC. Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care. 2009;13(5):R142.CrossRef
9.
go back to reference Yin WH, Chen Y, Jin XD, et al. Measurement of peak velocity variation of common carotid artery with bedside ultrasound to estimate preload in surgery ICU. Sichuan Da Xue Xue Bao Yi Xue Ban. 2013;44(4):624–8 [Article in Chinese].PubMed Yin WH, Chen Y, Jin XD, et al. Measurement of peak velocity variation of common carotid artery with bedside ultrasound to estimate preload in surgery ICU. Sichuan Da Xue Xue Bao Yi Xue Ban. 2013;44(4):624–8 [Article in Chinese].PubMed
10.
go back to reference Song Y, Kwak YL, Song JW, Kim YJ, Shim JK. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. Br J Anaesth. 2014;113(1):61–6.CrossRef Song Y, Kwak YL, Song JW, Kim YJ, Shim JK. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. Br J Anaesth. 2014;113(1):61–6.CrossRef
11.
go back to reference Ibarra-Estrada MÁ, López-Pulgarín JA, Mijangos-Méndez JC, Díaz-Gómez JL, Aguirre-Avalos G. Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study. Crit Ultrasound J. 2015;7(1):29.CrossRef Ibarra-Estrada MÁ, López-Pulgarín JA, Mijangos-Méndez JC, Díaz-Gómez JL, Aguirre-Avalos G. Respiratory variation in carotid peak systolic velocity predicts volume responsiveness in mechanically ventilated patients with septic shock: a prospective cohort study. Crit Ultrasound J. 2015;7(1):29.CrossRef
12.
go back to reference Zhu W, Wan L, Wan X, et al. Measurement of brachial artery velocity variation and inferior vena cava variability to estimate fluid responsiveness. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2016;28(8):713–7 [Article in Chinese].PubMed Zhu W, Wan L, Wan X, et al. Measurement of brachial artery velocity variation and inferior vena cava variability to estimate fluid responsiveness. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2016;28(8):713–7 [Article in Chinese].PubMed
14.
go back to reference Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.CrossRef Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.CrossRef
15.
go back to reference Harbord RM, Egger M, Sterne JA. A modified test for small-study effects in meta-analyses of controlled trials with binary endpoints. Stat Med. 2006;25(20):3443–57.CrossRef Harbord RM, Egger M, Sterne JA. A modified test for small-study effects in meta-analyses of controlled trials with binary endpoints. Stat Med. 2006;25(20):3443–57.CrossRef
16.
go back to reference Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18(6):650.CrossRef Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18(6):650.CrossRef
17.
go back to reference Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25(6):904–16.CrossRef Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25(6):904–16.CrossRef
18.
go back to reference Marik PE, Levitov A, Young A, Andrews L. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest. 2013;143(2):364–70.CrossRef Marik PE, Levitov A, Young A, Andrews L. The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest. 2013;143(2):364–70.CrossRef
19.
go back to reference Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111.CrossRef Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111.CrossRef
20.
go back to reference Sheng LF, Yan M, Zhang FJ, Ren QS, Yu SH, Wu M. The value of brachial artery peak velocity variation during the Valsalva maneuver to predict fluid responsiveness. Zhonghua Yi Xue Za Zhi. 2017;97(6):434–7 [Article in Chinese].PubMed Sheng LF, Yan M, Zhang FJ, Ren QS, Yu SH, Wu M. The value of brachial artery peak velocity variation during the Valsalva maneuver to predict fluid responsiveness. Zhonghua Yi Xue Za Zhi. 2017;97(6):434–7 [Article in Chinese].PubMed
Metadata
Title
Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
Authors
Bo Yao
Jian-yu Liu
Yun-bo Sun
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2018
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-018-0635-0

Other articles of this Issue 1/2018

BMC Anesthesiology 1/2018 Go to the issue