Excerpt

Patient motion, almost inevitable during the acquisition of medical images and radiation therapy, naturally generates artifacts and uncertainties as to the nature, delineation, and location of lesions and, hence, as to the most appropriate course of treatment. …
Literature
1.
go back to reference Li G, Citrin D, Camphausen K, Mueller B, Burman C, Mychalczak B, et al. Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat 2008;7(1):67–81. Feb.PubMed Li G, Citrin D, Camphausen K, Mueller B, Burman C, Mychalczak B, et al. Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat 2008;7(1):67–81. Feb.PubMed
2.
go back to reference Hamill JJ, Bosmans G, Dekker A. Respiratory-gated CT as a tool for the simulation of breathing artifacts in PET and PET/CT. Med Phys 2008;35(2):576–85. Feb.PubMedCrossRef Hamill JJ, Bosmans G, Dekker A. Respiratory-gated CT as a tool for the simulation of breathing artifacts in PET and PET/CT. Med Phys 2008;35(2):576–85. Feb.PubMedCrossRef
3.
go back to reference Dawood M, Buther F, Jiang X, Schafers KP. Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging 2008;27(8):1164–75. Aug.PubMedCrossRef Dawood M, Buther F, Jiang X, Schafers KP. Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging 2008;27(8):1164–75. Aug.PubMedCrossRef
4.
go back to reference Park SJ, Ionascu D, Killoran J, Mamede M, Gerbaudo VH, Chin L, et al. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images. Phys Med Biol 2008;53(13):3661–79. Jul 7.PubMedCrossRef Park SJ, Ionascu D, Killoran J, Mamede M, Gerbaudo VH, Chin L, et al. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images. Phys Med Biol 2008;53(13):3661–79. Jul 7.PubMedCrossRef
5.
go back to reference Brahme A, Nyman P, Skatt B. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. Med Phys 2008;35(5):1670–81. May.PubMedCrossRef Brahme A, Nyman P, Skatt B. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. Med Phys 2008;35(5):1670–81. May.PubMedCrossRef
6.
go back to reference Vines DC, Keller H, Hoisak JD, Breen SL. Quantitative PET comparing gated with nongated acquisitions using a NEMA phantom with respiratory-simulated motion. J Nucl Med Technol 2007;35(4):246–51. Dec.PubMedCrossRef Vines DC, Keller H, Hoisak JD, Breen SL. Quantitative PET comparing gated with nongated acquisitions using a NEMA phantom with respiratory-simulated motion. J Nucl Med Technol 2007;35(4):246–51. Dec.PubMedCrossRef
7.
go back to reference Schäfers KP, Stegger L. Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: image fusion and motion correction. Basic Res Cardiol 2008;103(2):191–9. Mar.PubMedCrossRef Schäfers KP, Stegger L. Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: image fusion and motion correction. Basic Res Cardiol 2008;103(2):191–9. Mar.PubMedCrossRef
8.
go back to reference Khurshid K, McGough RJ, Berger K. Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images. Phys Med Biol 2008;53(20):5705–18. Oct 21.PubMedCrossRef Khurshid K, McGough RJ, Berger K. Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images. Phys Med Biol 2008;53(20):5705–18. Oct 21.PubMedCrossRef
9.
go back to reference McQuaid SJ, Hutton BF. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT. Eur J Nucl Med Mol Imaging 2008;35(6):1117–23. Jun.PubMedCrossRef McQuaid SJ, Hutton BF. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT. Eur J Nucl Med Mol Imaging 2008;35(6):1117–23. Jun.PubMedCrossRef
Metadata
Title
Respiratory and cardiac motion correction with 4D PET imaging: shooting at moving targets
Author
Giovanni Lucignani
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 2/2009
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-008-1017-5

Other articles of this Issue 2/2009

European Journal of Nuclear Medicine and Molecular Imaging 2/2009 Go to the issue