Residual monomer elution from different conventional and CAD/CAM dental polymers during artificial aging

Authors: Madalena Lucia Pinheiro Dias Engler, Jan-Frederik Güth, Christine Keul, Kurt Erdelt, Daniel Edelhoff, Anja Liebermann

Published in: Clinical Oral Investigations | Issue 1/2020

Login to get access

Abstract

Objectives

Analyze and quantify the residual monomer elution of nine conventional and CAD/CAM (computer-aided design/computer-aided manufacturing) dental polymers during artificial aging.

Materials and methods

A total of 360 square–shaped specimens (14 × 12 × 2 ± 0.05 mm) were fabricated from eight CAD/CAM polymer blanks (n = 40): Avadent Base material, Avadent Teeth material, PMMA Multi blank, PMMA Mono blank, Temp Premium, Telio CAD, Ceramill Temp, Shofu Block HC, and conventional polymer PalaXpress. Specimens were aged in distilled water for 60 days at 37 °C and the evaluation of the residual monomer elution was made through UV spectrophotometry. Statistical analysis was carried out in the SPSS software. One-way ANOVA and Scheffé post hoc test were applied (α < 0.05).

Results

Aging time significantly changed the elution in all groups, except for PalaXpress. Statistically significant differences of elution were found between the materials. Shofu Block HC presented the highest, whereas PMMA Multi blank A3 and Mono blank A1 presented the lowest elution after the 60th day of aging.

Conclusions

CAD/CAM dental polymers as well as the conventional polymer PalaXpress eluted residual monomer within aging time. The differences in elution were material-dependent; still, the maximum elution found is below the specified threshold of ISO standard 20795-1.

Clinical relevance

With the evolution of CAD/CAM technology, material’s manufacturers have invested in the development of polymeric materials with higher resistance and stability to produce indirect restorations using CAD/CAM. It is expected that these materials present lower elution of residual monomer than conventional polymers.
Literature
1.
go back to reference Pfeiffer P, Rosenbauer EU (2004) Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials. J Prosthet Dent 92:72–78CrossRef Pfeiffer P, Rosenbauer EU (2004) Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials. J Prosthet Dent 92:72–78CrossRef
2.
go back to reference Kedjarune U, Charoenwolaruck N, Koontongkaew S (1999) Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J 44:25–30CrossRef Kedjarune U, Charoenwolaruck N, Koontongkaew S (1999) Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer. Aust Dent J 44:25–30CrossRef
3.
go back to reference Ivkovic N, Bozovic D, Ristic S, Mirjanic V, Jankovic O (2013) The residual monomer in dental acrylic resin and its adverse effects. Contemp Mater 4:84–91 Ivkovic N, Bozovic D, Ristic S, Mirjanic V, Jankovic O (2013) The residual monomer in dental acrylic resin and its adverse effects. Contemp Mater 4:84–91
4.
go back to reference Rao MRN, Reddy NS, Ramasay C, Banj RF (2016) Spectrophotometric analysis of residual monomer in acrylic resin samples processed with two different polymerization methods. Indian J Dent Sci 8:35–37 Rao MRN, Reddy NS, Ramasay C, Banj RF (2016) Spectrophotometric analysis of residual monomer in acrylic resin samples processed with two different polymerization methods. Indian J Dent Sci 8:35–37
5.
go back to reference Stafford GD, Brooks SC (1985) The loss of residual monomer from acrylic orthodontic resins. Dent Mater 1:135–138CrossRef Stafford GD, Brooks SC (1985) The loss of residual monomer from acrylic orthodontic resins. Dent Mater 1:135–138CrossRef
6.
go back to reference Goiato MC, Freitas E, Santos D, Medeiros R, Sonego M (2015) Acrylic resin cytotoxicity for denture base – literature review. Adv Clin Exp Med 24:679–686CrossRef Goiato MC, Freitas E, Santos D, Medeiros R, Sonego M (2015) Acrylic resin cytotoxicity for denture base – literature review. Adv Clin Exp Med 24:679–686CrossRef
7.
go back to reference Saravi ME, Vojdani M, Bahrani F (2012) Evaluation of cellular toxicity of three denture base acrylic resins. J Dent (Tehran) 9:180–188 Saravi ME, Vojdani M, Bahrani F (2012) Evaluation of cellular toxicity of three denture base acrylic resins. J Dent (Tehran) 9:180–188
8.
go back to reference Jorge JH, Giampaolo ET, Machado AL, Vergani CE (2003) Cytotoxicity of denture base acrylic resins: a literature review. J Prosthet Dent 90:190–193CrossRef Jorge JH, Giampaolo ET, Machado AL, Vergani CE (2003) Cytotoxicity of denture base acrylic resins: a literature review. J Prosthet Dent 90:190–193CrossRef
9.
go back to reference Lung CYK, Darvell BW (2005) Minimization of the inevitable residual monomer in denture base acrylic. Dent Mater 21:1119–1128CrossRef Lung CYK, Darvell BW (2005) Minimization of the inevitable residual monomer in denture base acrylic. Dent Mater 21:1119–1128CrossRef
10.
go back to reference Bettencourt AF, Neves CB, Almeida MS, Pinheiro LM, Oliveira SA, Lopes LP et al (2010) Biodegradation of acrylic based resins: a review. Dent Mater 26:e171–e180CrossRef Bettencourt AF, Neves CB, Almeida MS, Pinheiro LM, Oliveira SA, Lopes LP et al (2010) Biodegradation of acrylic based resins: a review. Dent Mater 26:e171–e180CrossRef
11.
go back to reference Urban VM, Cass QB, Oliveira RV, Giampaolo ET, Machado AL (2006) Development and application of methods for determination of residual monomer in dental acrylic resins using high performance liquid chromatography. Biomed Chromatogr 20:369–376CrossRef Urban VM, Cass QB, Oliveira RV, Giampaolo ET, Machado AL (2006) Development and application of methods for determination of residual monomer in dental acrylic resins using high performance liquid chromatography. Biomed Chromatogr 20:369–376CrossRef
12.
go back to reference Giunta JL, Grauer I, Zablotsky M (1979) Allergic contact stomatitis caused by acrylic resin. J Prosthet Dent 42:188–190CrossRef Giunta JL, Grauer I, Zablotsky M (1979) Allergic contact stomatitis caused by acrylic resin. J Prosthet Dent 42:188–190CrossRef
13.
go back to reference McCabe JF, Basker RM (1976) Tissue sensitivity to acrylic resin. A method of measuring the residual monomer content and its clinical application. Br Dent J 140:347–350CrossRef McCabe JF, Basker RM (1976) Tissue sensitivity to acrylic resin. A method of measuring the residual monomer content and its clinical application. Br Dent J 140:347–350CrossRef
14.
go back to reference Harrison A, Huggett R (1992) Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. J Dent 20:370–374CrossRef Harrison A, Huggett R (1992) Effect of the curing cycle on residual monomer levels of acrylic resin denture base polymers. J Dent 20:370–374CrossRef
15.
go back to reference Nisar S, Moeen F, Khan YH (2015) Effect of varying powder liquid ratios and curing conditions on the residual monomer concentration of heat cure acrylic resin. Pakistan Oral Dent J 35:713–718 Nisar S, Moeen F, Khan YH (2015) Effect of varying powder liquid ratios and curing conditions on the residual monomer concentration of heat cure acrylic resin. Pakistan Oral Dent J 35:713–718
16.
go back to reference Liu PR (2005) Panorama of dental CAD/CAM restorative systems. Compend Contin Educ Dent 26:507–513PubMed Liu PR (2005) Panorama of dental CAD/CAM restorative systems. Compend Contin Educ Dent 26:507–513PubMed
17.
go back to reference Karl M, Graef F, Wichmann M, Krafft T (2012) Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses. J Prosthet Dent 107:232–238CrossRef Karl M, Graef F, Wichmann M, Krafft T (2012) Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses. J Prosthet Dent 107:232–238CrossRef
18.
go back to reference Güth JF, Zuch T, Zwinge S, Engels J, Stimmelmayr M, Edelhoff D (2013) Optical properties of manually and CAD/CAM-fabricated polymers. Dent Mater J 32:865–871CrossRef Güth JF, Zuch T, Zwinge S, Engels J, Stimmelmayr M, Edelhoff D (2013) Optical properties of manually and CAD/CAM-fabricated polymers. Dent Mater J 32:865–871CrossRef
19.
go back to reference Güth JF, Magne P (2016) Optical integration of CAD/CAM materials. Int J Esthet Dent 11:394–409PubMed Güth JF, Magne P (2016) Optical integration of CAD/CAM materials. Int J Esthet Dent 11:394–409PubMed
20.
go back to reference Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J (2012) CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 107:34–46CrossRef Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J (2012) CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 107:34–46CrossRef
21.
go back to reference Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ (2015) Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent 114:818–825CrossRef Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ (2015) Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent 114:818–825CrossRef
22.
go back to reference Awad D, Stawarczyk B, Liebermann A, Ilie N (2015) Translucency of esthetic dental restorative CAD/CAM materials and composite resins with respect to thickness and surface roughness. J Prosthet Dent 113:534–540CrossRef Awad D, Stawarczyk B, Liebermann A, Ilie N (2015) Translucency of esthetic dental restorative CAD/CAM materials and composite resins with respect to thickness and surface roughness. J Prosthet Dent 113:534–540CrossRef
23.
go back to reference Fasbinder DJ (2010) Materials for chairside CAD/CAM restorations. Compend Contin Educ Dent 31:702–709PubMed Fasbinder DJ (2010) Materials for chairside CAD/CAM restorations. Compend Contin Educ Dent 31:702–709PubMed
24.
go back to reference Bural C, Aktas E, Deniz G, Ünlücerci Y, Bayraktar G (2011) Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles. J Appl Oral Sci 19:306–312CrossRef Bural C, Aktas E, Deniz G, Ünlücerci Y, Bayraktar G (2011) Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles. J Appl Oral Sci 19:306–312CrossRef
25.
go back to reference Dogan A, Bek B, Cevik NN, Usanmaz A (1995) The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption. J Dent 23:313–318CrossRef Dogan A, Bek B, Cevik NN, Usanmaz A (1995) The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption. J Dent 23:313–318CrossRef
26.
go back to reference Vallittu PK, Ruyter IE, Buykuilmaz S (1998) Effect of polymerization temperature and time on the residual monomer content of denture base polymers. Eur J Oral Sci 106:588–593CrossRef Vallittu PK, Ruyter IE, Buykuilmaz S (1998) Effect of polymerization temperature and time on the residual monomer content of denture base polymers. Eur J Oral Sci 106:588–593CrossRef
27.
go back to reference ISO 20795-1:2013 (2013) Dentistry – Base polymers – Part 1: Denture base polymers. Int Organ Standardization ISO 20795-1:2013 (2013) Dentistry – Base polymers – Part 1: Denture base polymers. Int Organ Standardization
28.
go back to reference Koda T, Tsuchiya H, Yamauchi M, Hoshino Y, Takagi N, Kawano J (1989) High-performance liquid chromatographic estimation of eluates from denture base polymers. J Dent 17:84–89CrossRef Koda T, Tsuchiya H, Yamauchi M, Hoshino Y, Takagi N, Kawano J (1989) High-performance liquid chromatographic estimation of eluates from denture base polymers. J Dent 17:84–89CrossRef
29.
go back to reference Lauvahutanon S, Shiozawa M, Takahashi H, Iwasaki N, Oki M, Finger WJ, Arksornnukit M (2017) Discoloration of various CAD/CAM blocks after immersion in coffee. Restor Dent Endod 42:9–18CrossRef Lauvahutanon S, Shiozawa M, Takahashi H, Iwasaki N, Oki M, Finger WJ, Arksornnukit M (2017) Discoloration of various CAD/CAM blocks after immersion in coffee. Restor Dent Endod 42:9–18CrossRef
30.
go back to reference Watanabe M (2004) Degradation and formation of bisphenol A in polycarbonate used in dentistry. J Med Dent Sci 51:1–6PubMed Watanabe M (2004) Degradation and formation of bisphenol A in polycarbonate used in dentistry. J Med Dent Sci 51:1–6PubMed
31.
go back to reference Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H (2017) Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig 21:1697–1705CrossRef Steinmassl PA, Wiedemair V, Huck C, Klaunzer F, Steinmassl O, Grunert I, Dumfahrt H (2017) Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig 21:1697–1705CrossRef
Metadata
Title
Residual monomer elution from different conventional and CAD/CAM dental polymers during artificial aging
Authors
Madalena Lucia Pinheiro Dias Engler
Jan-Frederik Güth
Christine Keul
Kurt Erdelt
Daniel Edelhoff
Anja Liebermann
Publication date
01-01-2020
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 1/2020
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-019-02947-4

Other articles of this Issue 1/2020

Clinical Oral Investigations 1/2020 Go to the issue