Abstract

Background

To assess the reliability of fetal heart volume measurement by three-dimensional sonography (3DUS) using the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method.

Methods

This reliability study enrolled 30 pregnant women with singleton healthy pregnancies between 19 and 34 weeks of gestation. All volume acquirements were performed with a convex volumetric transducer (C3-7ED) coupled to an Accuvix XQ sonography device (Medison, Korea). The XI VOCAL 10 planes was the method of choice for volumetric measurement. 3D datasets were analyzed by two observers (EQSB and HJFM); fetal heart volume was measured twice by the first and once by the second observer to calculate intra and interobserver reproducibility. Statistical analysis used pareated Student's t test (p) and calculated Intraclass correlation coefficients (ICC). Bland-Altman plots were also constructed.

Results

We observed an excellent intra- and interobserver reliability for fetal cardiac volume assessed by XI VOCAL. For the intraobserver the ICC was 0.998 (95% CI: 0.997; 0.999), with mean of differences of 0.12 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.130). For interobserver the ICC was 0.899 (95%CI: 0.996; 0.998), mean of differences 0.05 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.175).

Conclusion

Fetal cardiac volume assessed by 3DUS using XI VOCAL method is highly reproducible between 19 to 34 gestational weeks.
Appendix
Available only for authorised users
Literature
1.
go back to reference Allan LD, Cook A: Pulmonary atresia with intact ventricular septum in the fetus. Cardiol Young 1992, 2: 367-376. 10.1017/S1047951100007964CrossRef Allan LD, Cook A: Pulmonary atresia with intact ventricular septum in the fetus. Cardiol Young 1992, 2: 367-376. 10.1017/S1047951100007964CrossRef
2.
go back to reference Daubeney PE, Sharland GK, Cook AC, Keeton BR, Anderson RH, Webber SA: Pulmonary atresia with intact ventricular septum: impact of fetal echocardiography on incidence at birth and postnatal outcome. Circulation 1998, 98: 562-566.CrossRefPubMed Daubeney PE, Sharland GK, Cook AC, Keeton BR, Anderson RH, Webber SA: Pulmonary atresia with intact ventricular septum: impact of fetal echocardiography on incidence at birth and postnatal outcome. Circulation 1998, 98: 562-566.CrossRefPubMed
3.
go back to reference Riccabona M, Nelson TR, Pretorius DH: Three-dimensional ultrasound: accuracy of distance and volume measurements. Ultrasound Obstet Gynecol 1996, 7: 429-34. 10.1046/j.1469-0705.1996.07060429.xCrossRefPubMed Riccabona M, Nelson TR, Pretorius DH: Three-dimensional ultrasound: accuracy of distance and volume measurements. Ultrasound Obstet Gynecol 1996, 7: 429-34. 10.1046/j.1469-0705.1996.07060429.xCrossRefPubMed
4.
go back to reference Raine-Fenning NJ, Clewes JS, Kendall NR, Bunkheila AK, Campbell BK, Johnson IR: The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting. Ultrasound Obstet Gynecol 2003, 21: 283-291. 10.1002/uog.61CrossRefPubMed Raine-Fenning NJ, Clewes JS, Kendall NR, Bunkheila AK, Campbell BK, Johnson IR: The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting. Ultrasound Obstet Gynecol 2003, 21: 283-291. 10.1002/uog.61CrossRefPubMed
5.
go back to reference Chang FM, Hsu KF, Ko HC, Yao BL, Chang CH, Yu CH, Liang RI, Chen HY: Fetal heart volume assessment by three-dimensional ultrasound. Ultrasound Obstet Gynecol 1997, 9: 42-48. 10.1046/j.1469-0705.1997.09010042.xCrossRefPubMed Chang FM, Hsu KF, Ko HC, Yao BL, Chang CH, Yu CH, Liang RI, Chen HY: Fetal heart volume assessment by three-dimensional ultrasound. Ultrasound Obstet Gynecol 1997, 9: 42-48. 10.1046/j.1469-0705.1997.09010042.xCrossRefPubMed
6.
go back to reference Peralta CF, Cavoretto P, Csapo B, Falcon O, Nicolaides KH: Lung and heart volumes by three-dimensional ultrasound in normal fetuses at 12 - 32 weeks' gestation. Ultrasound Obstet Gynecol 2006, 27: 128-133. 10.1002/uog.2670CrossRefPubMed Peralta CF, Cavoretto P, Csapo B, Falcon O, Nicolaides KH: Lung and heart volumes by three-dimensional ultrasound in normal fetuses at 12 - 32 weeks' gestation. Ultrasound Obstet Gynecol 2006, 27: 128-133. 10.1002/uog.2670CrossRefPubMed
7.
go back to reference Guimarães Filho HA, da Costa LL, Araujo Júnior E, Pires CR, Nardozza LM, Mattar R: XI VOCAL (eXtended Imaging VOCAL): a new modality for three-dimensional sonographic volume measurement. Arch Gynecol Obstet 2007, 276: 95-97. 10.1007/s00404-006-0312-2CrossRefPubMed Guimarães Filho HA, da Costa LL, Araujo Júnior E, Pires CR, Nardozza LM, Mattar R: XI VOCAL (eXtended Imaging VOCAL): a new modality for three-dimensional sonographic volume measurement. Arch Gynecol Obstet 2007, 276: 95-97. 10.1007/s00404-006-0312-2CrossRefPubMed
8.
go back to reference Cheong KB, Leung KY, Chan HY, Lee YP, Yang F, Tang MH: Comparison of inter- and intraobserver agreement between three types of fetal volume measurement technique (XI VOCAL, VOCAL and multiplanar). Ultrasound Obstet Gynecol 2009, 33: 287-94. 10.1002/uog.6255CrossRefPubMed Cheong KB, Leung KY, Chan HY, Lee YP, Yang F, Tang MH: Comparison of inter- and intraobserver agreement between three types of fetal volume measurement technique (XI VOCAL, VOCAL and multiplanar). Ultrasound Obstet Gynecol 2009, 33: 287-94. 10.1002/uog.6255CrossRefPubMed
9.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed
10.
go back to reference Barreto EQ, Milani HF, Haratz KK, Rolo LC, Araujo Júnior E, Nardozza LM: Three-dimensional sonographic volumetry of phantom objects: comparing rotational method Virtual organ Computer-aided AnaLysis (VOCAL) to multi slice method Extended Imaging (XI) VOCAL. Ultrasound Obstet Gynecol 2009,34(Suppl 1):213-214. 10.1002/uog.7137CrossRef Barreto EQ, Milani HF, Haratz KK, Rolo LC, Araujo Júnior E, Nardozza LM: Three-dimensional sonographic volumetry of phantom objects: comparing rotational method Virtual organ Computer-aided AnaLysis (VOCAL) to multi slice method Extended Imaging (XI) VOCAL. Ultrasound Obstet Gynecol 2009,34(Suppl 1):213-214. 10.1002/uog.7137CrossRef
11.
go back to reference Ruano R, Benachi A, Martinovic J, Grebille AG, Aubry MC, Dumez Y, Dommergues M: Can three-dimensional ultrasound be used for the assessment of the fetal lung volume in cases of congenital diaphragmatic hernia? Fetal Diagn Ther 2004, 19: 87-91. 10.1159/000074268CrossRefPubMed Ruano R, Benachi A, Martinovic J, Grebille AG, Aubry MC, Dumez Y, Dommergues M: Can three-dimensional ultrasound be used for the assessment of the fetal lung volume in cases of congenital diaphragmatic hernia? Fetal Diagn Ther 2004, 19: 87-91. 10.1159/000074268CrossRefPubMed
Metadata
Title
Reproducibility of fetal heart volume by 3D-sonography using the XI VOCAL method
Authors
Enoch Q Barreto
Hérbene F Milani
Edward Araujo Júnior
Karina K Haratz
Liliam C Rolo
Luciano M Nardozza
Hélio A Guimarães Filho
Antonio F Moron
Publication date
01-12-2010
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2010
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-8-17

Other articles of this Issue 1/2010

Cardiovascular Ultrasound 1/2010 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine