Skip to main content
Top
Literature
1.
go back to reference Barczynski M, Konturek A, Cichon S (2008) Minimally invasive video-assisted thyroidectomy (MIVAT) with and without use of harmonic scalpel—a randomized study. Langenbeck’s Arch Surg 393:647–654CrossRef Barczynski M, Konturek A, Cichon S (2008) Minimally invasive video-assisted thyroidectomy (MIVAT) with and without use of harmonic scalpel—a randomized study. Langenbeck’s Arch Surg 393:647–654CrossRef
3.
4.
go back to reference Miccoli P, Materazzi G, Berti P (2008) New technologies in surgery: diagnosis and treatment of complications of MIVAT (minimally invasive video-assisted thyroidectomy). Pol J Surg 80:809–818 Miccoli P, Materazzi G, Berti P (2008) New technologies in surgery: diagnosis and treatment of complications of MIVAT (minimally invasive video-assisted thyroidectomy). Pol J Surg 80:809–818
5.
6.
go back to reference Sgourakis G, Sotiropoulos GC, Neuhäuser M, Musholt TJ, Karaliotas C, Lang H (2008) Comparison between minimally invasive video-assisted thyroidectomy and conventional thyroidectomy: is there any evidence-based information? Thyroid 18:721–727. doi:10.1089/thy.2008.0028 PubMedCrossRef Sgourakis G, Sotiropoulos GC, Neuhäuser M, Musholt TJ, Karaliotas C, Lang H (2008) Comparison between minimally invasive video-assisted thyroidectomy and conventional thyroidectomy: is there any evidence-based information? Thyroid 18:721–727. doi:10.​1089/​thy.​2008.​0028 PubMedCrossRef
7.
go back to reference Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17:1228–1230. doi:10.1007/s00464-002-8833-7 PubMedCrossRef Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17:1228–1230. doi:10.​1007/​s00464-002-8833-7 PubMedCrossRef
Metadata
Title
Reply to G. Dionigi’s letter: energy based devices and recurrent laryngeal nerve injury: the need for safer instruments
Author
Marcin Barczynski
Publication date
01-05-2009
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 3/2009
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-008-0450-z

Other articles of this Issue 3/2009

Langenbeck's Archives of Surgery 3/2009 Go to the issue

Case Management and Clinical Consequences

Sudden death after open gastric bypass surgery