Skip to main content
Top
Published in: Intensive Care Medicine 8/2009

01-08-2009 | Correspondence

Reply to Copetti and Cattarossi

Authors: Thomas Geeraerts, Olivier Bergès, Sybille Merceron, Yoann Launey, Dan Benhamou, Bernard Vigué, Jacques Duranteau

Published in: Intensive Care Medicine | Issue 8/2009

Login to get access

Excerpt

We thank Drs. Copetti and Cattarossi for their comments. We however disagree with the assumption that our results [1, 2] are related to artifacts. …
Literature
1.
go back to reference Geeraerts T, Merceron S, Benhamou D, Vigue B, Duranteau J (2008) Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 34:2062–2067PubMedCrossRef Geeraerts T, Merceron S, Benhamou D, Vigue B, Duranteau J (2008) Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 34:2062–2067PubMedCrossRef
2.
go back to reference Geeraerts T, Launey Y, Martin L, Pottecher J, Vigue B, Duranteau J, Benhamou D (2007) Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med 33:1704–1711PubMedCrossRef Geeraerts T, Launey Y, Martin L, Pottecher J, Vigue B, Duranteau J, Benhamou D (2007) Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med 33:1704–1711PubMedCrossRef
3.
go back to reference Blehar DJ, Gaspari RJ, Montoya A, Calderon R (2008) Correlation of visual axis and coronal axis measurements of the optic nerve sheath diamter. J Ultrasound Med 27:407–411PubMed Blehar DJ, Gaspari RJ, Montoya A, Calderon R (2008) Correlation of visual axis and coronal axis measurements of the optic nerve sheath diamter. J Ultrasound Med 27:407–411PubMed
4.
go back to reference Geeraerts T, Newcombe VFJ, Coles JP, Abate MG, Perkes IE, Hutchinson PJA, Outtrim JG, Chatfield DA, Menon DK (2008) Use of T2-weigthed magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure. Crit Care 12:R114PubMedCrossRef Geeraerts T, Newcombe VFJ, Coles JP, Abate MG, Perkes IE, Hutchinson PJA, Outtrim JG, Chatfield DA, Menon DK (2008) Use of T2-weigthed magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure. Crit Care 12:R114PubMedCrossRef
5.
go back to reference Berges O, Koskas P, Lafitte F, Piekarski JD (2006) Sonography of the eye and orbit with a multipurpose ultrasound unit. J Radiol 87:345–353PubMedCrossRef Berges O, Koskas P, Lafitte F, Piekarski JD (2006) Sonography of the eye and orbit with a multipurpose ultrasound unit. J Radiol 87:345–353PubMedCrossRef
Metadata
Title
Reply to Copetti and Cattarossi
Authors
Thomas Geeraerts
Olivier Bergès
Sybille Merceron
Yoann Launey
Dan Benhamou
Bernard Vigué
Jacques Duranteau
Publication date
01-08-2009
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 8/2009
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-009-1495-3

Other articles of this Issue 8/2009

Intensive Care Medicine 8/2009 Go to the issue