Skip to main content
Top
Published in: European Journal of Applied Physiology 5-6/2004

01-05-2004 | Original Article

Reliability of erector spinae oxygenation and blood volume responses using near-infrared spectroscopy in healthy males

Authors: Robert T. Kell, Mamdouh Farag, Yagesh Bhambhani

Published in: European Journal of Applied Physiology | Issue 5-6/2004

Login to get access

Abstract

The purpose of this investigation was to (1) describe the trends in oxygenation (OXY) and blood volume (BV) of the right and left paraspinal muscles during the Biering-Sorensen muscle endurance (BSME) test using near infrared spectroscopy (NIRS), and (2) assess the test-retest reliability of OXY and BV changes during the BSME in healthy males. Seventeen healthy males [age=28.4 (9.8) years, height=1.75 (0.05) m, body mass=82.7 (9.1) kg; mean (SD)] completed two BSME trials within 1 week. NIRS probes were placed bilaterally at lumbar 3. The test was performed with the subject in the prone position using the following protocol: 2 min baseline, BSME, and 4 min recovery. The delta and range values of OXY and BV were used for analysis. Acceptable intra-class correlations were observed for endurance time and all the NIRS variables at the point of fatigue and at each 10% segment of the BSME during the two trials. Bland-Altman plots confirmed the reproducibility of the bilateral NIRS responses of the paravertebral muscles. The BV responses were more reliable than the OXY responses during the two trials. The OXY and BV responses of the paravertebral muscles during static contractions can be measured reliably using NIRS. Future studies should focus primarily on BV for analysis.
Literature
go back to reference Alaranta H, Hurri H, Heliovaara M (1994) Non-dynamometric trunk performance tests: reliability and normative data. Scand J Rehabil Med 26:211–215PubMed Alaranta H, Hurri H, Heliovaara M (1994) Non-dynamometric trunk performance tests: reliability and normative data. Scand J Rehabil Med 26:211–215PubMed
go back to reference Barnes WS (1980) The relationship between maximum isometric strength and intramuscular circulatory occlusion. Ergonomics 23:351–357PubMed Barnes WS (1980) The relationship between maximum isometric strength and intramuscular circulatory occlusion. Ergonomics 23:351–357PubMed
go back to reference Biedermann H-J, Shanks GL, Inglis J (1990) Median frequency estimates of paraspinal muscles: reliability analysis. Electromyogr Clin Neurophysiol 30:83–88PubMed Biedermann H-J, Shanks GL, Inglis J (1990) Median frequency estimates of paraspinal muscles: reliability analysis. Electromyogr Clin Neurophysiol 30:83–88PubMed
go back to reference Biering-Sorensen F (1983) A prospective study of low back pain in a general population. Scand J Rehabil Med 15:81–88PubMed Biering-Sorensen F (1983) A prospective study of low back pain in a general population. Scand J Rehabil Med 15:81–88PubMed
go back to reference Biering-Sorensen F (1984a) Physical measurements as risk indicators for low-back trouble over a one-year period. Spine 9:106–119PubMed Biering-Sorensen F (1984a) Physical measurements as risk indicators for low-back trouble over a one-year period. Spine 9:106–119PubMed
go back to reference Biering-Sorensen F (1984b) A one-year prospective study of low back trouble in a general population. The prognostic value of low back history and physical measurements. Dan Med Bull 31:362–375PubMed Biering-Sorensen F (1984b) A one-year prospective study of low back trouble in a general population. The prognostic value of low back history and physical measurements. Dan Med Bull 31:362–375PubMed
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed
go back to reference Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087PubMed Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087PubMed
go back to reference Bonde-Petersen F, Mørk AL, Nielsen E (1975) Local muscle blood flow and sustained isometric contractions of human arm and back muscles. Eur J Appl Physiol 34:43–50 Bonde-Petersen F, Mørk AL, Nielsen E (1975) Local muscle blood flow and sustained isometric contractions of human arm and back muscles. Eur J Appl Physiol 34:43–50
go back to reference Chance B, Bank W (1995) Genetic disease of mitochondrial function evaluated by NMR and NIR spectroscopy of skeletal muscle. Biochim Biophys Acta 1271:7–14CrossRefPubMed Chance B, Bank W (1995) Genetic disease of mitochondrial function evaluated by NMR and NIR spectroscopy of skeletal muscle. Biochim Biophys Acta 1271:7–14CrossRefPubMed
go back to reference Chance B, Dait M, Zhang C (1992) Recovery from exercise-induced saturation in the quadriceps muscles of elite competitive rowers. Am J Physiol 262:C766-C775PubMed Chance B, Dait M, Zhang C (1992) Recovery from exercise-induced saturation in the quadriceps muscles of elite competitive rowers. Am J Physiol 262:C766-C775PubMed
go back to reference Fitts RH (1994) Cellular mechanisms of muscle fatigue. Physiol Rev 71:49–93 Fitts RH (1994) Cellular mechanisms of muscle fatigue. Physiol Rev 71:49–93
go back to reference Gaffney FA, Sjogaard G, Saltin B (1990) Cardiovascular and metabolic responses to static contraction in man. Acta Physiol Scand 138:249–258PubMed Gaffney FA, Sjogaard G, Saltin B (1990) Cardiovascular and metabolic responses to static contraction in man. Acta Physiol Scand 138:249–258PubMed
go back to reference Hansen J, Sander M, Hald CF (2000) Metabolic modulation of sympathetic vasoconstriction in human skeletal muscle: role of tissue hypoxia. J Physiol (Lond) 527:387–396 Hansen J, Sander M, Hald CF (2000) Metabolic modulation of sympathetic vasoconstriction in human skeletal muscle: role of tissue hypoxia. J Physiol (Lond) 527:387–396
go back to reference Humphreys PW, Lind AR (1962) The blood flow through active and inactive muscles of the forearm during sustained handgrip contractions. J Physiol (Lond) 166:120–135 Humphreys PW, Lind AR (1962) The blood flow through active and inactive muscles of the forearm during sustained handgrip contractions. J Physiol (Lond) 166:120–135
go back to reference Jensen BR, Jorgensen K, Hargens AR (1999) Physiological response to submaximal isometric contractions of the paravertebral muscles. Spine 24:2332–2338CrossRefPubMed Jensen BR, Jorgensen K, Hargens AR (1999) Physiological response to submaximal isometric contractions of the paravertebral muscles. Spine 24:2332–2338CrossRefPubMed
go back to reference Jørgensen K (1997) Human trunk extensor muscles physiology and ergonomics. Acta Physiol Scand 160:5–58 Jørgensen K (1997) Human trunk extensor muscles physiology and ergonomics. Acta Physiol Scand 160:5–58
go back to reference Jørgensen K, Nicolaisen T (1986) Two methods for determining trunk extensor endurance: A comparative study. Eur J Appl Physiol 55:639–644 Jørgensen K, Nicolaisen T (1986) Two methods for determining trunk extensor endurance: A comparative study. Eur J Appl Physiol 55:639–644
go back to reference Jørgensen K, Nicolaisen T (1987) Trunk extensor endurance: determination and relation to low-back trouble. Ergonomics 30:259–267PubMed Jørgensen K, Nicolaisen T (1987) Trunk extensor endurance: determination and relation to low-back trouble. Ergonomics 30:259–267PubMed
go back to reference Kankaanpaa M, Laaksonen D, Taimela S (1998) Age, sex, and body mass index as determinants of back and hip extensor fatigue in the isometric Sorensen back endurance test. Arch Phys Med Rehabil 79:1069–1075PubMed Kankaanpaa M, Laaksonen D, Taimela S (1998) Age, sex, and body mass index as determinants of back and hip extensor fatigue in the isometric Sorensen back endurance test. Arch Phys Med Rehabil 79:1069–1075PubMed
go back to reference Keller A, Hellesnes J, Jens IB, et al (2001) Reliability of the isokinetic trunk extensor test, Biering-Sorensen test, and Astrand bicycle test: assessment of intraclass correlation coefficient and critical difference in patients with chronic low back pain and healthy individuals. Spine 26:771–777CrossRefPubMed Keller A, Hellesnes J, Jens IB, et al (2001) Reliability of the isokinetic trunk extensor test, Biering-Sorensen test, and Astrand bicycle test: assessment of intraclass correlation coefficient and critical difference in patients with chronic low back pain and healthy individuals. Spine 26:771–777CrossRefPubMed
go back to reference Koumantakis GA, Arnall F, Cooper RG (2001) Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. Reliability in the context of clinical applications. Clin Biomech (Bristol, Avon) 16:263–266 Koumantakis GA, Arnall F, Cooper RG (2001) Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. Reliability in the context of clinical applications. Clin Biomech (Bristol, Avon) 16:263–266
go back to reference Latimer J, Maher CG, Refshauge K (1999) The reliability and validity of the Biering-Sorensen test in asymptomatic subjects and subjects reporting current or previous nonspecific low back pain. Spine 24:2085–2089; discussion 2090CrossRefPubMed Latimer J, Maher CG, Refshauge K (1999) The reliability and validity of the Biering-Sorensen test in asymptomatic subjects and subjects reporting current or previous nonspecific low back pain. Spine 24:2085–2089; discussion 2090CrossRefPubMed
go back to reference Maikala R, Bhambhani Y (2000) Low-back muscle oxygenation trends during simple postural variations-intersession reliability using near infra-red spectroscopy. IEA2000/HFES Congress, pp 5–9; 9–12 Maikala R, Bhambhani Y (2000) Low-back muscle oxygenation trends during simple postural variations-intersession reliability using near infra-red spectroscopy. IEA2000/HFES Congress, pp 5–9; 9–12
go back to reference Mancini D, Bolinger L, Li L (1994) Validation of near-infrared spectroscopy in humans. J Appl Physiol 77:2740–2745PubMed Mancini D, Bolinger L, Li L (1994) Validation of near-infrared spectroscopy in humans. J Appl Physiol 77:2740–2745PubMed
go back to reference Mannion AF, Dolan P (1994) Electromyographic median frequency changes during isometric contraction of the back extensors to fatigue. Spine 19:1223–1229PubMed Mannion AF, Dolan P (1994) Electromyographic median frequency changes during isometric contraction of the back extensors to fatigue. Spine 19:1223–1229PubMed
go back to reference Marshall JM (2000) Adenosine and muscle vasodilatation in acute systemic hypoxia. Acta Physiol Scand 168:561–573CrossRefPubMed Marshall JM (2000) Adenosine and muscle vasodilatation in acute systemic hypoxia. Acta Physiol Scand 168:561–573CrossRefPubMed
go back to reference Mayer T, Gatchel R, Betancur J (1995) Trunk muscle endurance measurement. Spine 20:920–927PubMed Mayer T, Gatchel R, Betancur J (1995) Trunk muscle endurance measurement. Spine 20:920–927PubMed
go back to reference McGill SM, Hughson RL, Parks K (2000) Lumbar erector spinae oxygenation during prolonged contractions: implications for prolonged work. Ergonomics 43:486–493CrossRefPubMed McGill SM, Hughson RL, Parks K (2000) Lumbar erector spinae oxygenation during prolonged contractions: implications for prolonged work. Ergonomics 43:486–493CrossRefPubMed
go back to reference Mitchell JH, Payne FC, Saltin B (1980) The role of muscle mass in the cardiovascular response to static exercise. J Physiol (Lond) 309:45–54 Mitchell JH, Payne FC, Saltin B (1980) The role of muscle mass in the cardiovascular response to static exercise. J Physiol (Lond) 309:45–54
go back to reference Moffroid MT, Haugh LD, Haig AJ (1993) Endurance training of trunk extensor muscles. Phys Ther 73:10–17PubMed Moffroid MT, Haugh LD, Haig AJ (1993) Endurance training of trunk extensor muscles. Phys Ther 73:10–17PubMed
go back to reference Moffroid MT, Reid S, Henry SM (1994) Some endurance measures in persons with chronic low back pain. J Orthop Sports Phys Ther 20:81–87PubMed Moffroid MT, Reid S, Henry SM (1994) Some endurance measures in persons with chronic low back pain. J Orthop Sports Phys Ther 20:81–87PubMed
go back to reference Moreland J, Finch E, Stratford P (1997) Interrater reliability of six tests of trunk muscle function and endurance. J Orthop Sports Phys Ther 26:200–208PubMed Moreland J, Finch E, Stratford P (1997) Interrater reliability of six tests of trunk muscle function and endurance. J Orthop Sports Phys Ther 26:200–208PubMed
go back to reference Newton M, Thow M, Somerville D (1993) Trunk strength testing with isomachines, part 2. Experimental evaluation of the Cybex II back testing system in normal subjects and patients with chronic low back pain. Spine 18:812–824PubMed Newton M, Thow M, Somerville D (1993) Trunk strength testing with isomachines, part 2. Experimental evaluation of the Cybex II back testing system in normal subjects and patients with chronic low back pain. Spine 18:812–824PubMed
go back to reference Obrig H, Villringer A (1997) Near-infrared spectroscopy in functional activation studies. Can NIRS demonstrate cortical activation? In: Villringer A, Dirnagl W (eds) Optical imaging of brain function and metabolism II. Advances in experimental medicince and biology. Plenum Press, New York, pp 113–127 Obrig H, Villringer A (1997) Near-infrared spectroscopy in functional activation studies. Can NIRS demonstrate cortical activation? In: Villringer A, Dirnagl W (eds) Optical imaging of brain function and metabolism II. Advances in experimental medicince and biology. Plenum Press, New York, pp 113–127
go back to reference Ottenbacher KJ (1991) Statistical conclusion validity multiple inferences in rehabilitation medicine. Am J Phys Med Rehabil 70:317–322PubMed Ottenbacher KJ (1991) Statistical conclusion validity multiple inferences in rehabilitation medicine. Am J Phys Med Rehabil 70:317–322PubMed
go back to reference Radegran G, Hellsten Y (2000) Adenosine and nitric oxide in exercise-induced human skeletal muscle vasodilatation. Acta Physiol Scand 168:575–591CrossRefPubMed Radegran G, Hellsten Y (2000) Adenosine and nitric oxide in exercise-induced human skeletal muscle vasodilatation. Acta Physiol Scand 168:575–591CrossRefPubMed
go back to reference Sjogaard G, Savard G, Juel C (1988) Muscle blood flow during isometric activity and its relation to muscle fatigue. Eur J Appl Physiol 57:327–335 Sjogaard G, Savard G, Juel C (1988) Muscle blood flow during isometric activity and its relation to muscle fatigue. Eur J Appl Physiol 57:327–335
go back to reference Smidt GL, Blanpied PR (1987) Analysis of strength tests and resistive exercises commonly used for low-back disorders. Spine 12:1025–1031PubMed Smidt GL, Blanpied PR (1987) Analysis of strength tests and resistive exercises commonly used for low-back disorders. Spine 12:1025–1031PubMed
go back to reference Suni JH, Oja P, Miilunpalo SI (1998) Health-related fitness test battery for adults: associations with perceived health, mobility, and back function and symptoms. Arch Phys Med Rehabil 79:559–569PubMed Suni JH, Oja P, Miilunpalo SI (1998) Health-related fitness test battery for adults: associations with perceived health, mobility, and back function and symptoms. Arch Phys Med Rehabil 79:559–569PubMed
go back to reference Wenger HA, Reed AT (1976) Metabolic factors associated with muscular fatigue during aerobic and anaerobic work. Can J Appl Physiol 1:43–48 Wenger HA, Reed AT (1976) Metabolic factors associated with muscular fatigue during aerobic and anaerobic work. Can J Appl Physiol 1:43–48
go back to reference Yoshitake Y, Ue H, Miyazaki M (2001) Assessment of lower-back muscle fatigue using electromyography, mechanomyography, and near-infrared spectroscopy. Eur J Appl Physiol 84:174–179 Yoshitake Y, Ue H, Miyazaki M (2001) Assessment of lower-back muscle fatigue using electromyography, mechanomyography, and near-infrared spectroscopy. Eur J Appl Physiol 84:174–179
Metadata
Title
Reliability of erector spinae oxygenation and blood volume responses using near-infrared spectroscopy in healthy males
Authors
Robert T. Kell
Mamdouh Farag
Yagesh Bhambhani
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 5-6/2004
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-003-1014-0

Other articles of this Issue 5-6/2004

European Journal of Applied Physiology 5-6/2004 Go to the issue