Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 5/2021

01-05-2021 | Refractive Errors | Trauma

Sutureless scleral fixation: comparison between 3-piece IOL and new single-piece foldable IOL

Authors: Isabella D’Agostino, Salvatore Parrulli, Stefano De Angelis, Alessandro Invernizzi, Ferdinando Bottoni, Giovanni Staurenghi, Matteo Giuseppe Cereda

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 5/2021

Login to get access

Abstract

Purpose

Comparing two different sutureless scleral fixation techniques.

Methods

A retrospective study of patients who underwent sutureless scleral fixation IOL from October 2013 to May 2018 at “Luigi Sacco Hospital”, University of Milan. Comparison between two groups: Group 1 implanted with a 3-piece ALCON-MA60AC and group 2 implanted with a newly developed single-piece foldable IOL SOLEKO FIL-SSF. Patients underwent a complete preoperative ophthalmic assessment and post-operative evaluation at 1, 3, and 6 months. Vitrectomy was performed in all cases. The two groups were compared for age, axial length, and lens status at baseline. Visual acuity, refractive results, surgical time, and post-operative complications were recorded.

Results

Thirty-one eyes were included: group 1, 15 eyes of 15 patients, and group 2, 16 eyes of 14 patients. No difference was found in visual acuity. Mean refractive error was 1D in both groups (group 1 1.01D, group 2 1.09D), but spherical equivalent was more often moved toward negative values and induced astigmatism was greater in the 3-piece group (group 1 1.91D [SD ± 2.07], group 2 0.67D [SD ± 0.88] P = 0.04). Surgical procedure was faster in group 2 (mean time difference 21′, P = 0.01*). New displacement occurred in 5 cases (33%) of group 1 and in no cases of group 2 (P = 0.01*). Post-operative bleeding was registered only in group 1 (20%), but the difference was not statistically significant.

Conclusions

The group 2 IOL gives in our sample better results due to less post-operative astigmatism and reducing dislocation and bleeding during follow-up. Surgical technique appeared easier and faster: the specifically designed IOL seems to be a feasible solution for sutureless scleral fixation.
Appendix
Available only for authorised users
Literature
7.
16.
go back to reference Kershner RM (1994) Simple method of transscleral fixation of a posterior chamber intraocular lens in the absence of the lens capsule. J Refract Corneal Surg 10(6):647–651CrossRef Kershner RM (1994) Simple method of transscleral fixation of a posterior chamber intraocular lens in the absence of the lens capsule. J Refract Corneal Surg 10(6):647–651CrossRef
Metadata
Title
Sutureless scleral fixation: comparison between 3-piece IOL and new single-piece foldable IOL
Authors
Isabella D’Agostino
Salvatore Parrulli
Stefano De Angelis
Alessandro Invernizzi
Ferdinando Bottoni
Giovanni Staurenghi
Matteo Giuseppe Cereda
Publication date
01-05-2021
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 5/2021
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-020-04980-6

Other articles of this Issue 5/2021

Graefe's Archive for Clinical and Experimental Ophthalmology 5/2021 Go to the issue