Abstract

Background

Currently, the reduction and support of comminuted medial cortex of humeral fracture remains a challenge, Therefore, a novel reduction and fixation technique that employs an anteromedial small locking plate was explored in this study, and its viability and the associated complications were assessed.

Methods

Fifteen cases of proximal humeral fractures with medial instability (five cases were classified as three-part and ten as four-part by Neer classification) were treated by the proposed reduction technique using an anteromedial small locking plate. Subsequently, the radiological and clinical outcomes were evaluated over an average follow-up period of 18.53 months.

Results

The average operation time was 108 min (range, 70–130 min), and the mean fracture union time in all patients was 12.13 weeks (range, 8–16 weeks). Complications such as infection and neurovascular injury were not observed. Postoperative X-ray showed avascular necrosis and screw penetration in one patient, while screw penetration, varus malunion, or significant reduction loss was not found in the other cases. The mean Constant score was 79.8 (range, 68–92) during the final visit.

Conclusions

The use of an anteromedial small locking plate improved the reduction efficiency, reconstructed the medial support, and alleviated the occurrence of complications in proximal humeral fractures with medial instability.
Literature
1.
go back to reference Biermann N, Prall WC, Böcker W, Mayr HO, Haasters F. Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies. Arch Orthop Trauma Surg. 2019;139:1075–99.CrossRef Biermann N, Prall WC, Böcker W, Mayr HO, Haasters F. Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies. Arch Orthop Trauma Surg. 2019;139:1075–99.CrossRef
2.
go back to reference Aaron D, Shatsky J, Paredes JC, Jiang C, Parsons BO, Flatow EL. Proximal humeral fractures: internal fixation. J Bone Jt Surg Am. 2012;94:2280–8. Aaron D, Shatsky J, Paredes JC, Jiang C, Parsons BO, Flatow EL. Proximal humeral fractures: internal fixation. J Bone Jt Surg Am. 2012;94:2280–8.
3.
go back to reference Maier D, Jaeger M, Izadpanah K, Strohm PC, Suedkamp NP. Proximal humeral fracture treatment in adults. J Bone Jt Surg Am. 2014;96:251–61.CrossRef Maier D, Jaeger M, Izadpanah K, Strohm PC, Suedkamp NP. Proximal humeral fracture treatment in adults. J Bone Jt Surg Am. 2014;96:251–61.CrossRef
4.
go back to reference Konrad G, Bayer J, Hepp P, Voigt C, Oestern H, Kääb M, et al. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Surgical technique. J Bone Jt Surg Am. 2010;92(Suppl 1):85–95.CrossRef Konrad G, Bayer J, Hepp P, Voigt C, Oestern H, Kääb M, et al. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Surgical technique. J Bone Jt Surg Am. 2010;92(Suppl 1):85–95.CrossRef
5.
go back to reference Spross C, Grueninger P, Gohil S, Dietrich M. Open reduction and internal fixation of fractures of the proximal part of the humerus. JBJS Essent Surg Tech. 2015;5:e15.CrossRef Spross C, Grueninger P, Gohil S, Dietrich M. Open reduction and internal fixation of fractures of the proximal part of the humerus. JBJS Essent Surg Tech. 2015;5:e15.CrossRef
6.
go back to reference Fleischhacker E, Siebenbürger G, Helfen T, Gleich J, Böcker W, Ockert B. Varus malposition relates to functional outcomes following open reduction and internal fixation for proximal humeral fractures: a retrospective comparative cohort study with minimum 2 years follow-up. Injury. 2021;52:506–10.CrossRef Fleischhacker E, Siebenbürger G, Helfen T, Gleich J, Böcker W, Ockert B. Varus malposition relates to functional outcomes following open reduction and internal fixation for proximal humeral fractures: a retrospective comparative cohort study with minimum 2 years follow-up. Injury. 2021;52:506–10.CrossRef
7.
go back to reference Schnetzke M, Bockmeyer J, Porschke F, Studier-Fischer S, Grützner PA, Guehring T. Quality of reduction influences outcome after locked-plate fixation of proximal humeral type-C fractures. J Bone Jt Surg Am. 2016;98:1777–85.CrossRef Schnetzke M, Bockmeyer J, Porschke F, Studier-Fischer S, Grützner PA, Guehring T. Quality of reduction influences outcome after locked-plate fixation of proximal humeral type-C fractures. J Bone Jt Surg Am. 2016;98:1777–85.CrossRef
8.
go back to reference Laux CJ, Grubhofer F, Werner CML, Simmen H-P, Osterhoff G. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12:137.CrossRef Laux CJ, Grubhofer F, Werner CML, Simmen H-P, Osterhoff G. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12:137.CrossRef
9.
go back to reference Choi S, Seo KB, Kwon YS, Kang H, Cho C, Rho JY. Dual plate for comminuted proximal humerus fractures. Acta Orthop Belg. 2019;85:429–36.PubMed Choi S, Seo KB, Kwon YS, Kang H, Cho C, Rho JY. Dual plate for comminuted proximal humerus fractures. Acta Orthop Belg. 2019;85:429–36.PubMed
10.
go back to reference Wang J-Q, Jiang B-J, Guo W-J, Zhao Y-M. Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study. BMC Musculoskelet Disord. 2018;19:420.CrossRef Wang J-Q, Jiang B-J, Guo W-J, Zhao Y-M. Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study. BMC Musculoskelet Disord. 2018;19:420.CrossRef
11.
go back to reference Padegimas EM, Chang G, Namjouyan K, Namdari S. Failure to restore the calcar and locking screw cross-threading predicts varus collapse in proximal humerus fracture fixation. J Shoulder Elbow Surg. 2020;29:291–5.CrossRef Padegimas EM, Chang G, Namjouyan K, Namdari S. Failure to restore the calcar and locking screw cross-threading predicts varus collapse in proximal humerus fracture fixation. J Shoulder Elbow Surg. 2020;29:291–5.CrossRef
12.
go back to reference Liskutin T, Harkin E, Summers H, Cohen J, Bernstein M, Lack W. The influence of biplanar reduction and surgeon experience on proximal humerus fractures treated with ORIF. Injury. 2020;51:322–8.CrossRef Liskutin T, Harkin E, Summers H, Cohen J, Bernstein M, Lack W. The influence of biplanar reduction and surgeon experience on proximal humerus fractures treated with ORIF. Injury. 2020;51:322–8.CrossRef
13.
go back to reference Barlow JD, Logli AL, Steinmann SP, Sems SA, Cross WW, Yuan BJ, et al. Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate. J Shoulder Elbow Surg. 2020;29:1689–94.CrossRef Barlow JD, Logli AL, Steinmann SP, Sems SA, Cross WW, Yuan BJ, et al. Locking plate fixation of proximal humerus fractures in patients older than 60 years continues to be associated with a high complication rate. J Shoulder Elbow Surg. 2020;29:1689–94.CrossRef
14.
go back to reference Theopold J, Schleifenbaum S, Müller M, Werner M, Hammer N, Josten C, et al. Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures. PloS One. 2018;13:e0206349.CrossRef Theopold J, Schleifenbaum S, Müller M, Werner M, Hammer N, Josten C, et al. Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures. PloS One. 2018;13:e0206349.CrossRef
15.
go back to reference Theopold J, Marquaß B, Fakler J, Steinke H, Josten C, Hepp P. The bicipital groove as a landmark for reconstruction of complex proximal humeral fractures with hybrid double plate osteosynthesis. BMC Surg. 2016;16:10.CrossRef Theopold J, Marquaß B, Fakler J, Steinke H, Josten C, Hepp P. The bicipital groove as a landmark for reconstruction of complex proximal humeral fractures with hybrid double plate osteosynthesis. BMC Surg. 2016;16:10.CrossRef
16.
go back to reference He Y, Zhang Y, Wang Y, Zhou D, Wang F. Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support. J Orthop Surg Res. 2017;12:72.CrossRef He Y, Zhang Y, Wang Y, Zhou D, Wang F. Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support. J Orthop Surg Res. 2017;12:72.CrossRef
17.
go back to reference Gerber C, Schneeberger AG, Vinh TS. The arterial vascularization of the humeral head. An anatomical study. J Bone Jt Surg Am. 1990;72:1486–94.CrossRef Gerber C, Schneeberger AG, Vinh TS. The arterial vascularization of the humeral head. An anatomical study. J Bone Jt Surg Am. 1990;72:1486–94.CrossRef
18.
go back to reference Hettrich CM, Boraiah S, Dyke JP, Neviaser A, Helfet DL, Lorich DG. Quantitative assessment of the vascularity of the proximal part of the humerus. J Bone Jt Surg Am. 2010;92:943–8.CrossRef Hettrich CM, Boraiah S, Dyke JP, Neviaser A, Helfet DL, Lorich DG. Quantitative assessment of the vascularity of the proximal part of the humerus. J Bone Jt Surg Am. 2010;92:943–8.CrossRef
19.
go back to reference Campochiaro G, Rebuzzi M, Baudi P, Catani F. Complex proximal humerus fractures: Hertel’s criteria reliability to predict head necrosis. Musculoskelet Surg. 2015;99 Suppl 1:S9-S15. Campochiaro G, Rebuzzi M, Baudi P, Catani F. Complex proximal humerus fractures: Hertel’s criteria reliability to predict head necrosis. Musculoskelet Surg. 2015;99 Suppl 1:S9-S15.
20.
go back to reference Hertel R, Hempfing A, Stiehler M, Leunig M. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elbow Surg. 2004;13:427–33.CrossRef Hertel R, Hempfing A, Stiehler M, Leunig M. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elbow Surg. 2004;13:427–33.CrossRef
21.
go back to reference Lee CW, Shin SJ. Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Shoulder Elbow Surg. 2009;18:83–88.CrossRef Lee CW, Shin SJ. Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation. J Shoulder Elbow Surg. 2009;18:83–88.CrossRef
22.
go back to reference Owsley KC, Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures. J Bone Jt Surg Am. 2008;90:233–40.CrossRef Owsley KC, Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures. J Bone Jt Surg Am. 2008;90:233–40.CrossRef
Metadata
Title
Reduction and fixation of proximal humeral fracture with severe medial instability using a small locking plate
Authors
Yuelei Zhang
Lifu Wan
Lecheng Zhang
Chao Yan
Gang Wang
Publication date
01-12-2021
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2021
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-021-01388-9

Other articles of this Issue 1/2021

BMC Surgery 1/2021 Go to the issue