Skip to main content
Top
Published in: Journal of Medical Systems 1/2023

Open Access 01-12-2023 | Original Paper

Reducing Medication Errors by Adopting Automatic Dispensing Cabinets in Critical Care Units

Authors: Hui-Ning Tu, Tzu-Hao Shan, Yu-Chin Wu, Pei-Hsuan Shen, Tsung-Yu Wu, Wen-Liang Lin, Yea-Huei Yang-Kao, Ching-Lan Cheng

Published in: Journal of Medical Systems | Issue 1/2023

Login to get access

Abstract

Medication errors can have severe consequences and threaten patient safety. The patient safety-related benefits of automated dispensing cabinets (ADCs) have been reported by several previous studies, including a reduction in medication errors in intensive care units (ICUs) and emergency departments. However, the benefits of ADCs need to be assessed, given the different healthcare practice models. This study aimed to compare the rates of medication errors, including prescription, dispensing, and administrative, before and after using ADCs in intensive care units. The prescription, dispensing, and administrative error data before and after the adoption of ADCs were retrospectively collected from the medication error report system. The severity of medication errors was classified according to the National Coordinating Council for Medication Error Reporting and Prevention guidelines. The study outcome was the rate of medication errors. After the adoption of ADCs in the intensive care units, the rates of prescription and dispensing errors reduced from 3.03 to 1.75 per 100,000 prescriptions and 3.87 to 0 per 100,000 dispensations, respectively. The administrative error rate decreased from 0.046 to 0.026%. The ADCs decreased National Coordinating Council for Medication Error Reporting and Prevention category B and D errors by 75% and category C errors by 43%. To improve medication safety, multidisciplinary collaboration and strategies, such as the use of automated dispensing cabinets, education, and training programs from a systems perspective, are warranted.
Appendix
Available only for authorised users
Literature
2.
go back to reference Tariq RA, Vashisht R, Sinha A, Scherbak Y. Medication dispensing errors and prevention. StatPearls. Treasure Island (FL): StatPearls Publishing. Copyright. StatPearls Publishing LLC. 2022. Tariq RA, Vashisht R, Sinha A, Scherbak Y. Medication dispensing errors and prevention. StatPearls. Treasure Island (FL): StatPearls Publishing. Copyright. StatPearls Publishing LLC. 2022.
3.
go back to reference Prgomet M, Li L, Niazkhani Z, Georgiou A, Westbrook JI. Impact of commercial computerized provider order entry (CPOE) and clinical decision support systems (CDSSs) on medication errors, length of stay, and mortality in intensive care units: a systematic review and meta-analysis. J Am Med Inform Assoc. 2017;24:413–22.CrossRefPubMed Prgomet M, Li L, Niazkhani Z, Georgiou A, Westbrook JI. Impact of commercial computerized provider order entry (CPOE) and clinical decision support systems (CDSSs) on medication errors, length of stay, and mortality in intensive care units: a systematic review and meta-analysis. J Am Med Inform Assoc. 2017;24:413–22.CrossRefPubMed
4.
go back to reference Austin JA, Smith IR, Tariq A. The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments. Int J Pharm Pract. 2018;26:526–33.CrossRefPubMed Austin JA, Smith IR, Tariq A. The impact of closed-loop electronic medication management on time to first dose: a comparative study between paper and digital hospital environments. Int J Pharm Pract. 2018;26:526–33.CrossRefPubMed
5.
go back to reference Wang E-Y, Hu H-Y, Hong Y-C, Ai M-Y, Chen T-J, Chen Y-C, et al. Implementation of automated dispensing cabinet to improve process of inpatient drug delivery. Formosa. J Clin Pharm. 2021;29:253–68. Wang E-Y, Hu H-Y, Hong Y-C, Ai M-Y, Chen T-J, Chen Y-C, et al. Implementation of automated dispensing cabinet to improve process of inpatient drug delivery. Formosa. J Clin Pharm. 2021;29:253–68.
6.
go back to reference Chapuis C, Roustit M, Bal G, Schwebel C, Pansu P, David-Tchouda S, et al. Automated drug dispensing system reduces medication errors in an intensive care setting. Crit Care Med. 2010;38:2275–81.CrossRefPubMed Chapuis C, Roustit M, Bal G, Schwebel C, Pansu P, David-Tchouda S, et al. Automated drug dispensing system reduces medication errors in an intensive care setting. Crit Care Med. 2010;38:2275–81.CrossRefPubMed
7.
go back to reference Fanning L, Jones N, Manias E. Impact of automated dispensing cabinets on medication selection and preparation error rates in an emergency department: a prospective and direct observational before-and-after study. J Eval Clin Pract. 2016;22:156–63.CrossRefPubMed Fanning L, Jones N, Manias E. Impact of automated dispensing cabinets on medication selection and preparation error rates in an emergency department: a prospective and direct observational before-and-after study. J Eval Clin Pract. 2016;22:156–63.CrossRefPubMed
8.
go back to reference Risør BW, Lisby M, Sørensen J. Complex automated medication systems reduce medication administration errors in a Danish acute medical unit. Int J Qual Health Care. 2018;30:457–65.CrossRefPubMed Risør BW, Lisby M, Sørensen J. Complex automated medication systems reduce medication administration errors in a Danish acute medical unit. Int J Qual Health Care. 2018;30:457–65.CrossRefPubMed
9.
go back to reference Franklin BD, O’Grady K, Donyai P, Jacklin A, Barber N. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study. Qual Saf Health Care. 2007;16:279–84.CrossRefPubMedPubMedCentral Franklin BD, O’Grady K, Donyai P, Jacklin A, Barber N. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study. Qual Saf Health Care. 2007;16:279–84.CrossRefPubMedPubMedCentral
10.
11.
go back to reference Merchan C, Soliman J, Ahuja T, Arnouk S, Keeley K, Tracy J, et al. COVID-19 pandemic preparedness: A practical guide from an operational pharmacy perspective. Am J Health Syst Pharm. 2020;77:1598–605.CrossRefPubMed Merchan C, Soliman J, Ahuja T, Arnouk S, Keeley K, Tracy J, et al. COVID-19 pandemic preparedness: A practical guide from an operational pharmacy perspective. Am J Health Syst Pharm. 2020;77:1598–605.CrossRefPubMed
12.
go back to reference Barker KN, Flynn EA, Pepper GA, Bates DW, Mikeal RL. Medication errors observed in 36 health care facilities. Arch Intern Med. 2002;162:1897–903.CrossRefPubMed Barker KN, Flynn EA, Pepper GA, Bates DW, Mikeal RL. Medication errors observed in 36 health care facilities. Arch Intern Med. 2002;162:1897–903.CrossRefPubMed
14.
go back to reference James KL, Barlow D, McArtney R, Hiom S, Roberts D, Whittlesea C. Incidence, type and causes of dispensing errors: a review of the literature. Int J Pharm Pract. 2009;17:9–30.CrossRefPubMed James KL, Barlow D, McArtney R, Hiom S, Roberts D, Whittlesea C. Incidence, type and causes of dispensing errors: a review of the literature. Int J Pharm Pract. 2009;17:9–30.CrossRefPubMed
15.
go back to reference Aldhwaihi K, Schifano F, Pezzolesi C, Umaru N. A systematic review of the nature of dispensing errors in hospital pharmacies. Integr Pharm Res Pract. 2016;5:1–10.PubMedPubMedCentral Aldhwaihi K, Schifano F, Pezzolesi C, Umaru N. A systematic review of the nature of dispensing errors in hospital pharmacies. Integr Pharm Res Pract. 2016;5:1–10.PubMedPubMedCentral
16.
go back to reference Ahtiainen HK, Kallio MM, Airaksinen M, Holmström AR. Safety, time and cost evaluation of automated and semi-automated drug distribution systems in hospitals: a systematic review. Eur J Hosp Pharm. 2020;27:253–62.CrossRefPubMed Ahtiainen HK, Kallio MM, Airaksinen M, Holmström AR. Safety, time and cost evaluation of automated and semi-automated drug distribution systems in hospitals: a systematic review. Eur J Hosp Pharm. 2020;27:253–62.CrossRefPubMed
17.
go back to reference Jumeau M, Francois O, Bonnabry P. Impact of automated dispensing cabinets on dispensing errors, interruptions and pillbox preparation time. Eur J Hosp Pharm. 2021. Jumeau M, Francois O, Bonnabry P. Impact of automated dispensing cabinets on dispensing errors, interruptions and pillbox preparation time. Eur J Hosp Pharm. 2021.
18.
go back to reference Irwin A., Ross J., Seaton J., Mearns K. Retrospective analysis of DATIX dispensing error reports from Scottish NHS hospitals. Int J Pharm Pract 2011; 19: 417–23.CrossRefPubMed Irwin A., Ross J., Seaton J., Mearns K. Retrospective analysis of DATIX dispensing error reports from Scottish NHS hospitals. Int J Pharm Pract 2011; 19: 417–23.CrossRefPubMed
19.
go back to reference Institute of Medicine Committee on Quality of health care in A. In. In: Kohn LT, Corrigan JM, Donaldson MS, editors. To err is human: building a safer health system. Washington (DC): National Academies Press (US) Copyright; 2000. p. 2000 by the National Academy of Sciences. All rights reserved. Institute of Medicine Committee on Quality of health care in A. In. In: Kohn LT, Corrigan JM, Donaldson MS, editors. To err is human: building a safer health system. Washington (DC): National Academies Press (US) Copyright; 2000. p. 2000 by the National Academy of Sciences. All rights reserved.
20.
go back to reference Dib JG, Abdulmohsin SA, Farooki MU, Mohammed K, Iqbal M, Khan JA. Effects of an automated drug dispensing system on medication adverse event occurrences and cost containment at SAMSO. Hosp Pharm. 2006;41:1180–5.CrossRef Dib JG, Abdulmohsin SA, Farooki MU, Mohammed K, Iqbal M, Khan JA. Effects of an automated drug dispensing system on medication adverse event occurrences and cost containment at SAMSO. Hosp Pharm. 2006;41:1180–5.CrossRef
21.
go back to reference Cottney A. Improving the safety and efficiency of nurse medication rounds through the introduction of an automated dispensing cabinet. BMJ Qual Improv Rep. 2014;3. Cottney A. Improving the safety and efficiency of nurse medication rounds through the introduction of an automated dispensing cabinet. BMJ Qual Improv Rep. 2014;3.
22.
23.
go back to reference Bourne RS, Shulman R, Jennings JK. Reducing medication errors in critical care patients: pharmacist key resources and relationship with medicines optimisation. Int J Pharm Pract. 2018;26:534–40.CrossRefPubMed Bourne RS, Shulman R, Jennings JK. Reducing medication errors in critical care patients: pharmacist key resources and relationship with medicines optimisation. Int J Pharm Pract. 2018;26:534–40.CrossRefPubMed
24.
go back to reference Tsao NW, Lo C, Babich M, Shah K, Bansback NJ. Decentralized automated dispensing devices: systematic review of clinical and economic impacts in hospitals. Can J Hosp Pharm. 2014;67:138–48.PubMedPubMedCentral Tsao NW, Lo C, Babich M, Shah K, Bansback NJ. Decentralized automated dispensing devices: systematic review of clinical and economic impacts in hospitals. Can J Hosp Pharm. 2014;67:138–48.PubMedPubMedCentral
25.
go back to reference Klopotowska JE, Kuiper R, Van Kan HJ, De Pont AC, Dijkgraaf MG, Lie-A-Huen L, et al. On-ward participation of a hospital pharmacist in a Dutch intensive care unit reduces prescribing errors and related patient harm: an intervention study. Crit Care. 2010;14:R174.CrossRefPubMedPubMedCentral Klopotowska JE, Kuiper R, Van Kan HJ, De Pont AC, Dijkgraaf MG, Lie-A-Huen L, et al. On-ward participation of a hospital pharmacist in a Dutch intensive care unit reduces prescribing errors and related patient harm: an intervention study. Crit Care. 2010;14:R174.CrossRefPubMedPubMedCentral
26.
go back to reference Cho I, Park H, Choi YJ, Hwang MH, Bates DW. Understanding the nature of medication errors in an ICU with a computerized physician order entry system. PLOS ONE. 2014;9:e114243.CrossRefPubMedPubMedCentral Cho I, Park H, Choi YJ, Hwang MH, Bates DW. Understanding the nature of medication errors in an ICU with a computerized physician order entry system. PLOS ONE. 2014;9:e114243.CrossRefPubMedPubMedCentral
27.
go back to reference Cello R, Conley M, Cooley T, De la Torre C, Dorn M, Ferer DS, et al. ASHP guidelines on the safe use of automated dispensing cabinets. Am J Health Syst Pharm. 2022;79:e71-82.CrossRef Cello R, Conley M, Cooley T, De la Torre C, Dorn M, Ferer DS, et al. ASHP guidelines on the safe use of automated dispensing cabinets. Am J Health Syst Pharm. 2022;79:e71-82.CrossRef
Metadata
Title
Reducing Medication Errors by Adopting Automatic Dispensing Cabinets in Critical Care Units
Authors
Hui-Ning Tu
Tzu-Hao Shan
Yu-Chin Wu
Pei-Hsuan Shen
Tsung-Yu Wu
Wen-Liang Lin
Yea-Huei Yang-Kao
Ching-Lan Cheng
Publication date
01-12-2023
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 1/2023
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-023-01953-0

Other articles of this Issue 1/2023

Journal of Medical Systems 1/2023 Go to the issue