Skip to main content
Top
Published in: Radiation Oncology 1/2014

Open Access 01-12-2014 | Research

Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer

Authors: Seong Soon Jang, Gil Ja Huh, Suk Young Park, Po Song Yang, Hae Nam Chung, Jae Hyuk Seo, Ji Chan Park, Young Jun Yang, Eun Youn Cho

Published in: Radiation Oncology | Issue 1/2014

Login to get access

Abstract

Background

To evaluate the volumetric and geometric differences in the ITVs generated by four-dimensional (4D) computed tomography (CT), a modified slow CT scan, and a combination of these CT methods in lung cancer patients treated with stereotactic body radiotherapy (SBRT).

Methods

Both 4D CT and modified slow CT using a multi-slice CT scanner were performed for SBRT planning in 14 patients with 15 pulmonary targets. Volumetric and geometric analyses were performed for (1) ITVall, generated by combining the gross tumor volumes (GTVs) from all 8 phases of the 4D CT; (2) ITV2, generated by combining the GTVs from 2 extreme phases of the 4D CT; (3) ITVslow, derived from the GTV on the modified slow CT scan; (4) ITVall+slow, generated by combining ITVall and ITVslow; and (5) ITV2+slow, generated by combining ITV2 and ITVslow. Three SBRT plans were performed using 3 ITVs to assess the dosimetric effects on normal lung caused by the various target volumes.

Results

ITVall (11.8 ± 8.3 cm3) was significantly smaller than ITVall+slow (12.5 ± 8.9 cm3), with mean values of 5.8% for the percentage volume difference, and a mean of 7.5% of ITVslow was not encompassed in ITVall. The geometric coverages of ITV2 and ITVslow for ITVall were 84.7 ± 6.6% and 76.2 ± 9.3%, respectively, but the coverage for ITVall increased to 90.9 ± 5.9% by using the composite of these two ITVs. There were statistically significant increases in the lung-dose parameters of the plans based on ITVall+slow compared to the plans based on ITVall or ITV2+slow. However, the magnitudes of these differences were relatively small, with a value of less than 3% in all dosimetric parameters.

Conclusions

Due to its ability to provides additional motion information, the combination of 4D CT and a modified slow CT scan in SBRT planning for lung cancer can be used to reduce possible errors in true target delineation caused by breathing pattern variations.
Appendix
Available only for authorised users
Literature
1.
go back to reference Chi A, Liao Z, Nguyen NP, Xu J, Stea B, Komaki R: Systemic review of the patterns of failure following stereotactic body radiation therapy in early-stage non-small-cell lung cancer: clinical implications. Radiother Oncol 2010, 94: 1-11. 10.1016/j.radonc.2009.12.008CrossRefPubMed Chi A, Liao Z, Nguyen NP, Xu J, Stea B, Komaki R: Systemic review of the patterns of failure following stereotactic body radiation therapy in early-stage non-small-cell lung cancer: clinical implications. Radiother Oncol 2010, 94: 1-11. 10.1016/j.radonc.2009.12.008CrossRefPubMed
2.
go back to reference Stevens CW, Munden RF, Forster KM, Kelly JF, Liao Z, Starkschall G, Tucker S, Komaki R: Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. Int J Radiat Oncol Biol Phys 2001, 51: 62-68.CrossRefPubMed Stevens CW, Munden RF, Forster KM, Kelly JF, Liao Z, Starkschall G, Tucker S, Komaki R: Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. Int J Radiat Oncol Biol Phys 2001, 51: 62-68.CrossRefPubMed
3.
go back to reference Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, van Herk M, Lebesque JV, Miyasaka K: Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 2002, 53: 822-834. 10.1016/S0360-3016(02)02803-1CrossRefPubMed Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, van Herk M, Lebesque JV, Miyasaka K: Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 2002, 53: 822-834. 10.1016/S0360-3016(02)02803-1CrossRefPubMed
4.
go back to reference Loo BW Jr, Kavanagh BD, Meyer JL: Motion management and image guidance for thoracic tumor radiotherapy: clinical treatment programs. Front Radiat Ther Oncol 2011, 43: 271-291.CrossRefPubMed Loo BW Jr, Kavanagh BD, Meyer JL: Motion management and image guidance for thoracic tumor radiotherapy: clinical treatment programs. Front Radiat Ther Oncol 2011, 43: 271-291.CrossRefPubMed
5.
go back to reference ICRU Report 62: Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50). Bethesda: International Commission on Radiation Units and Measurement; 1999. ICRU Report 62: Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50). Bethesda: International Commission on Radiation Units and Measurement; 1999.
6.
go back to reference Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006, 33: 3874-3900. 10.1118/1.2349696CrossRefPubMed Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006, 33: 3874-3900. 10.1118/1.2349696CrossRefPubMed
7.
go back to reference Jiang SB: Radiotherapy of mobile tumors. Semin Radiat Oncol 2006, 16: 239-248. 10.1016/j.semradonc.2006.04.007CrossRefPubMed Jiang SB: Radiotherapy of mobile tumors. Semin Radiat Oncol 2006, 16: 239-248. 10.1016/j.semradonc.2006.04.007CrossRefPubMed
8.
go back to reference De Ruysscher D, Faivre-Finn C, Nestle U, Hurkmans CW, Le Péchoux C, Price A, Senan S: European organisation for research and treatment of cancer recommendations for planning and delivery of high-dose, high-precision radiotherapy for lung cancer. J Clin Oncol 2010, 28: 5301-5310. 10.1200/JCO.2010.30.3271CrossRefPubMed De Ruysscher D, Faivre-Finn C, Nestle U, Hurkmans CW, Le Péchoux C, Price A, Senan S: European organisation for research and treatment of cancer recommendations for planning and delivery of high-dose, high-precision radiotherapy for lung cancer. J Clin Oncol 2010, 28: 5301-5310. 10.1200/JCO.2010.30.3271CrossRefPubMed
9.
go back to reference Slotman BJ, Lagerwaard FJ, Senan S: 4D imaging for target definition in stereotactic radiotherapy for lung cancer. Acta Oncol 2006, 45: 966-972. 10.1080/02841860600902817CrossRefPubMed Slotman BJ, Lagerwaard FJ, Senan S: 4D imaging for target definition in stereotactic radiotherapy for lung cancer. Acta Oncol 2006, 45: 966-972. 10.1080/02841860600902817CrossRefPubMed
10.
go back to reference Chang JY, Cox JD: Improving radiation conformality in the treatment of non-small cell lung cancer. Semin Radiat Oncol 2010, 20: 171-177. 10.1016/j.semradonc.2010.01.005PubMedCentralCrossRefPubMed Chang JY, Cox JD: Improving radiation conformality in the treatment of non-small cell lung cancer. Semin Radiat Oncol 2010, 20: 171-177. 10.1016/j.semradonc.2010.01.005PubMedCentralCrossRefPubMed
11.
go back to reference de Koste JR, Lagerwaard FJ, de Boer HC, Nijssen-Visser MR, Senan S: Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? Int J Radiat Oncol Biol Phys 2003, 55: 1394-1399. 10.1016/S0360-3016(02)04602-3CrossRefPubMed de Koste JR, Lagerwaard FJ, de Boer HC, Nijssen-Visser MR, Senan S: Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? Int J Radiat Oncol Biol Phys 2003, 55: 1394-1399. 10.1016/S0360-3016(02)04602-3CrossRefPubMed
12.
go back to reference Bradley JD, Nofal AN, El Naqa IM, Lu W, Liu J, Hubenschmidt J, Low DA, Drzymala RE, Khullar D: Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 2006, 81: 264-268. 10.1016/j.radonc.2006.10.009CrossRefPubMed Bradley JD, Nofal AN, El Naqa IM, Lu W, Liu J, Hubenschmidt J, Low DA, Drzymala RE, Khullar D: Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 2006, 81: 264-268. 10.1016/j.radonc.2006.10.009CrossRefPubMed
13.
go back to reference Seki S, Kunieda E, Takeda A, Nagaoka T, Deloar HM, Kawase T, Fukada J, Kawaguchi O, Uematsu M, Kubo A: Differences in the definition of internal target volumes using slow CT alone or in combination with thin-slice CT under breath-holding conditions during the planning of stereotactic radiotherapy for lung cancer. Radiother Oncol 2007, 85: 443-449. 10.1016/j.radonc.2007.10.010CrossRefPubMed Seki S, Kunieda E, Takeda A, Nagaoka T, Deloar HM, Kawase T, Fukada J, Kawaguchi O, Uematsu M, Kubo A: Differences in the definition of internal target volumes using slow CT alone or in combination with thin-slice CT under breath-holding conditions during the planning of stereotactic radiotherapy for lung cancer. Radiother Oncol 2007, 85: 443-449. 10.1016/j.radonc.2007.10.010CrossRefPubMed
14.
go back to reference Nakamura M, Narita Y, Matsuo Y, Narabayashi M, Nakata M, Yano S, Miyabe Y, Matsugi K, Sawada A, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M: Geometrical differences in target volumes between slow CT and 4D CT imaging in stereotactic body radiotherapy for lung tumors in the upper and middle lobe. Med Phys 2008, 35: 4142-4148. 10.1118/1.2968096CrossRefPubMed Nakamura M, Narita Y, Matsuo Y, Narabayashi M, Nakata M, Yano S, Miyabe Y, Matsugi K, Sawada A, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M: Geometrical differences in target volumes between slow CT and 4D CT imaging in stereotactic body radiotherapy for lung tumors in the upper and middle lobe. Med Phys 2008, 35: 4142-4148. 10.1118/1.2968096CrossRefPubMed
15.
go back to reference Ge H, Cai J, Kelsey CR, Yin FF: Quantification and minimization of uncertainties of internal target volume for stereotactic body radiation therapy of lung cancer. Int J Radiat Oncol Biol Phys 2013, 85: 438-443. 10.1016/j.ijrobp.2012.04.032CrossRefPubMed Ge H, Cai J, Kelsey CR, Yin FF: Quantification and minimization of uncertainties of internal target volume for stereotactic body radiation therapy of lung cancer. Int J Radiat Oncol Biol Phys 2013, 85: 438-443. 10.1016/j.ijrobp.2012.04.032CrossRefPubMed
16.
go back to reference Chinneck CD, McJury M, Hounsell AR: The potential for undertaking slow CT using a modern CT scanner. Br J Radiol 2010, 83: 687-693. 10.1259/bjr/31551018PubMedCentralCrossRefPubMed Chinneck CD, McJury M, Hounsell AR: The potential for undertaking slow CT using a modern CT scanner. Br J Radiol 2010, 83: 687-693. 10.1259/bjr/31551018PubMedCentralCrossRefPubMed
17.
go back to reference Liu HH, Balter P, Tutt T, Choi B, Zhang J, Wang C, Chi M, Luo D, Pan T, Hunjan S, Starkschall G, Rosen I, Prado K, Liao Z, Chang J, Komaki R, Cox JD, Mohan R, Dong L: Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. Int J Radiat Oncol Biol Phys 2007, 68: 531-540. 10.1016/j.ijrobp.2006.12.066CrossRefPubMed Liu HH, Balter P, Tutt T, Choi B, Zhang J, Wang C, Chi M, Luo D, Pan T, Hunjan S, Starkschall G, Rosen I, Prado K, Liao Z, Chang J, Komaki R, Cox JD, Mohan R, Dong L: Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. Int J Radiat Oncol Biol Phys 2007, 68: 531-540. 10.1016/j.ijrobp.2006.12.066CrossRefPubMed
18.
go back to reference Lagerwaard FJ, de Koste JR VS, Nijssen-Visser MR, Schuchhard-Schipper RH, Oei SS, Munne A, Senan S: Multiple “slow” CT scans for incorporating lung tumor mobility in radiotherapy planning. Int J Radiat Oncol Biol Phys 2001, 51: 932-937. 10.1016/S0360-3016(01)01716-3CrossRefPubMed Lagerwaard FJ, de Koste JR VS, Nijssen-Visser MR, Schuchhard-Schipper RH, Oei SS, Munne A, Senan S: Multiple “slow” CT scans for incorporating lung tumor mobility in radiotherapy planning. Int J Radiat Oncol Biol Phys 2001, 51: 932-937. 10.1016/S0360-3016(01)01716-3CrossRefPubMed
19.
go back to reference Wurstbauer K, Deutschmann H, Kopp P, Sedlmayer F: Radiotherapy planning for lung cancer: slow CTs allow the drawing of tighter margins. Radiother Oncol 2005, 75: 165-170. 10.1016/j.radonc.2005.02.003CrossRefPubMed Wurstbauer K, Deutschmann H, Kopp P, Sedlmayer F: Radiotherapy planning for lung cancer: slow CTs allow the drawing of tighter margins. Radiother Oncol 2005, 75: 165-170. 10.1016/j.radonc.2005.02.003CrossRefPubMed
20.
go back to reference Muirhead R, McNee SG, Featherstone C, Moore K, Muscat S: Use of maximum intensity projections (MIPs) for target outlining in 4DCT radiotherapy planning. J Thorac Oncol 2008, 3: 1433-1438. 10.1097/JTO.0b013e31818e5db7CrossRefPubMed Muirhead R, McNee SG, Featherstone C, Moore K, Muscat S: Use of maximum intensity projections (MIPs) for target outlining in 4DCT radiotherapy planning. J Thorac Oncol 2008, 3: 1433-1438. 10.1097/JTO.0b013e31818e5db7CrossRefPubMed
21.
go back to reference Ezhil M, Vedam S, Balter P, Choi B, Mirkovic D, Starkschall G, Chang JY: Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography. Radiat Oncol 2009, 4: 4. 10.1186/1748-717X-4-4PubMedCentralCrossRefPubMed Ezhil M, Vedam S, Balter P, Choi B, Mirkovic D, Starkschall G, Chang JY: Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography. Radiat Oncol 2009, 4: 4. 10.1186/1748-717X-4-4PubMedCentralCrossRefPubMed
22.
go back to reference Rietzel E, Liu AK, Doppke KP, Wolfgang JA, Chen AB, Chen GT, Choi NC: Design of 4D treatment planning target volumes. Int J Radiat Oncol Biol Phys 2006, 66: 287-295. 10.1016/j.ijrobp.2006.05.024CrossRefPubMed Rietzel E, Liu AK, Doppke KP, Wolfgang JA, Chen AB, Chen GT, Choi NC: Design of 4D treatment planning target volumes. Int J Radiat Oncol Biol Phys 2006, 66: 287-295. 10.1016/j.ijrobp.2006.05.024CrossRefPubMed
23.
go back to reference Borst GR, Ishikawa M, Nijkamp J, Hauptmann M, Shirato H, Onimaru R, van den Heuvel MM, Belderbos J, Lebesque JV, Sonke JJ: Radiation pneumonitis in patients treated for malignant pulmonary lesions with hypofractionated radiation therapy. Radiother Oncol 2009, 91: 307-313. 10.1016/j.radonc.2009.02.003CrossRefPubMed Borst GR, Ishikawa M, Nijkamp J, Hauptmann M, Shirato H, Onimaru R, van den Heuvel MM, Belderbos J, Lebesque JV, Sonke JJ: Radiation pneumonitis in patients treated for malignant pulmonary lesions with hypofractionated radiation therapy. Radiother Oncol 2009, 91: 307-313. 10.1016/j.radonc.2009.02.003CrossRefPubMed
24.
go back to reference Matsuo Y, Shibuya K, Nakamura M, Narabayashi M, Sakanaka K, Ueki N, Miyagi K, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M: Dose–volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer. Int J Radiat Oncol Biol Phys 2012, 83: e545-e549. 10.1016/j.ijrobp.2012.01.018CrossRefPubMed Matsuo Y, Shibuya K, Nakamura M, Narabayashi M, Sakanaka K, Ueki N, Miyagi K, Norihisa Y, Mizowaki T, Nagata Y, Hiraoka M: Dose–volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer. Int J Radiat Oncol Biol Phys 2012, 83: e545-e549. 10.1016/j.ijrobp.2012.01.018CrossRefPubMed
25.
go back to reference Barriger RB, Forquer JA, Brabham JG, Andolino DL, Shapiro RH, Henderson MA, Johnstone PA, Fakiris AJ: A dose-volume analysis of radiation pneumonitis in non-small cell lung cancer patients treated with stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys 2012, 82: 457-462. 10.1016/j.ijrobp.2010.08.056CrossRefPubMed Barriger RB, Forquer JA, Brabham JG, Andolino DL, Shapiro RH, Henderson MA, Johnstone PA, Fakiris AJ: A dose-volume analysis of radiation pneumonitis in non-small cell lung cancer patients treated with stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys 2012, 82: 457-462. 10.1016/j.ijrobp.2010.08.056CrossRefPubMed
26.
go back to reference Baker R, Han G, Sarangkasiri S, DeMarco M, Turke C, Stevens CW, Dilling TJ: Clinical and dosimetric predictors of radiation pneumonitis in a large series of patients treated with stereotactic body radiation therapy to the lung. Int J Radiat Oncol Biol Phys 2013, 85: 190-195. 10.1016/j.ijrobp.2012.03.041CrossRefPubMed Baker R, Han G, Sarangkasiri S, DeMarco M, Turke C, Stevens CW, Dilling TJ: Clinical and dosimetric predictors of radiation pneumonitis in a large series of patients treated with stereotactic body radiation therapy to the lung. Int J Radiat Oncol Biol Phys 2013, 85: 190-195. 10.1016/j.ijrobp.2012.03.041CrossRefPubMed
Metadata
Title
Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer
Authors
Seong Soon Jang
Gil Ja Huh
Suk Young Park
Po Song Yang
Hae Nam Chung
Jae Hyuk Seo
Ji Chan Park
Young Jun Yang
Eun Youn Cho
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2014
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-9-106

Other articles of this Issue 1/2014

Radiation Oncology 1/2014 Go to the issue