Abstract

Purpose

The role of the radioguided occult lesion localisation (ROLL) technique in breast cancer has been increasing in recent years. One of the important drawbacks of such a technique is radiotracer spillage within the mammary gland that makes the precise lesion resection difficult, and this requires the use of a hook-wire collocation to reach the lesion. The possibility of obtaining an intraoperative image of the specimen could help to confirm whether the lesion is correctly removed. Some types of portable gamma cameras have been designed, but up to now, intraoperative use has been confined to surgery of parathyroid adenomas and sentinel lymph node location. The aim of the study was to value the usefulness of an intraoperative gamma camera to assess the resection of non-palpable breast lesions.

Materials and methods

The study involved 42 women diagnosed with non-palpable early breast cancer. Lymphoscintigraphy was performed on the day before surgery by injection of 99mTc-labelled nanocolloid. During surgery a gamma probe was used to guide the surgeon, and afterwards images of the surgical bed and the tumoral specimen were acquired by means of a portable gamma camera, fitted with a pinhole collimator. A 99mTc pointer was used to draw an outline image around the specimen.

Results

On lymphoscintigraphy, radiotracer was concentrated in 31 cases. During surgery, all lesions were removed. In the images acquired by the portable gamma camera, the lesion was centred inside the surgical specimen in 23 of 42 cases, non-centred in 15 and in contact in 4 cases. Congruence of 60% was found between the intraoperative images and the histopathological results. The posterior margin was the most frequently involved. The whole acquisition time for the tumoral specimen with its margins was 5 min at most.

Conclusion

The use of portable gamma cameras in theatre is in an early phase. The short period of time required during the surgical procedure will allow the surgical team to improve this technique until it can replace hand-held probes. The intraoperative acquisition of such images can predict the involvement of surgical margins, avoiding future surgical procedures.
Literature
1.
go back to reference De Cicco C, Pizzamiglio M, Trifirò G, Luini A, Ferrari M, Prisco G. Radioguided occult lesion localisation (ROLL) and surgical biopsy in breast cancer. Q J Nucl Med. 2002;46:145–51.PubMed De Cicco C, Pizzamiglio M, Trifirò G, Luini A, Ferrari M, Prisco G. Radioguided occult lesion localisation (ROLL) and surgical biopsy in breast cancer. Q J Nucl Med. 2002;46:145–51.PubMed
2.
go back to reference Zgajnar J, Hocevar M, Frkovic-Grazio S, Hertl K, Scheweiger E, Besic N. Radioguided occult lesion localization (ROLL) of the nonpalpable breast lesions. Neoplasma. 2004;51:385–9.PubMed Zgajnar J, Hocevar M, Frkovic-Grazio S, Hertl K, Scheweiger E, Besic N. Radioguided occult lesion localization (ROLL) of the nonpalpable breast lesions. Neoplasma. 2004;51:385–9.PubMed
3.
go back to reference Thind CR, Desmond S, Harris O, Nadeem R, Chagla LS, Audisio RA. Radio-guided localization of clinical occult breast lesions (ROLL): a DGH experience. Clin Radiol. 2005;60:681–6.PubMedCrossRef Thind CR, Desmond S, Harris O, Nadeem R, Chagla LS, Audisio RA. Radio-guided localization of clinical occult breast lesions (ROLL): a DGH experience. Clin Radiol. 2005;60:681–6.PubMedCrossRef
4.
go back to reference Cortés Romera M, Pardo García R, Soriano Castrejón A, García Vicente A, Ruiz Díaz M, Poblete García VM. Localización radioguiada de lesiones ocultas de mama (ROLL). Rev Esp Med Nucl. 2005;24:374–9.PubMedCrossRef Cortés Romera M, Pardo García R, Soriano Castrejón A, García Vicente A, Ruiz Díaz M, Poblete García VM. Localización radioguiada de lesiones ocultas de mama (ROLL). Rev Esp Med Nucl. 2005;24:374–9.PubMedCrossRef
5.
go back to reference Gray RJ, Salud C, Nguyen K, Dauway E, Friedland J, Berman C. Randomized prospective evaluation of a novel technique for biopsy of lumpectomy of nonpalpable breast lesions: radioactive seed versus wire localization. Ann Surg Oncol. 2001;8:711–5.PubMedCrossRef Gray RJ, Salud C, Nguyen K, Dauway E, Friedland J, Berman C. Randomized prospective evaluation of a novel technique for biopsy of lumpectomy of nonpalpable breast lesions: radioactive seed versus wire localization. Ann Surg Oncol. 2001;8:711–5.PubMedCrossRef
6.
go back to reference Abe A, Takahashi N, Lee J, Oka T, Shizukuishi K, Kikuchi T. Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera. Eur J Nucl Med Mol Imaging. 2003;30:805–11.PubMedCrossRef Abe A, Takahashi N, Lee J, Oka T, Shizukuishi K, Kikuchi T. Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera. Eur J Nucl Med Mol Imaging. 2003;30:805–11.PubMedCrossRef
7.
go back to reference Tsuchimochi M, Sakahara H, Hayama K, Funaki M, Ohno R, Shirahata T, et al. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications. Eur J Nucl Med Mol Imaging. 2003;30:1605–14.PubMedCrossRef Tsuchimochi M, Sakahara H, Hayama K, Funaki M, Ohno R, Shirahata T, et al. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications. Eur J Nucl Med Mol Imaging. 2003;30:1605–14.PubMedCrossRef
8.
go back to reference Pitre S, Menard L, Ricard M, Solal M, Garbay JR, Charon Y. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience. Eur J Nucl Med Mol Imaging. 2003;30:339–43.PubMedCrossRef Pitre S, Menard L, Ricard M, Solal M, Garbay JR, Charon Y. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience. Eur J Nucl Med Mol Imaging. 2003;30:339–43.PubMedCrossRef
9.
go back to reference Fernandez MM, Benlloch JM, Cerdá J, Escat B, Giménez EN, Giménez M, et al. A flat-panel-based mini gamma camera for lymph nodes studies. Nucl Instrum Methods Phys Res A. 2004;527:92–6.CrossRef Fernandez MM, Benlloch JM, Cerdá J, Escat B, Giménez EN, Giménez M, et al. A flat-panel-based mini gamma camera for lymph nodes studies. Nucl Instrum Methods Phys Res A. 2004;527:92–6.CrossRef
10.
go back to reference Ortega J, Ferrer-Rebolleda J, Cassinello N, Lledo S. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy. Eur J Nucl Med Mol Imaging. 2007;34:165–9.PubMedCrossRef Ortega J, Ferrer-Rebolleda J, Cassinello N, Lledo S. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy. Eur J Nucl Med Mol Imaging. 2007;34:165–9.PubMedCrossRef
11.
go back to reference Kitagawa W, Shimizu K, Akasu H. Radioguided parathyroidectomy for primary hyperparathyroidism using the solid-state, multi-crystal gamma camera. Med Sci Monit. 2003;9:CS53–6.PubMed Kitagawa W, Shimizu K, Akasu H. Radioguided parathyroidectomy for primary hyperparathyroidism using the solid-state, multi-crystal gamma camera. Med Sci Monit. 2003;9:CS53–6.PubMed
12.
go back to reference Mathelin C, Salvador S, Huss D, Guyonnet JL. Precise localization of sentinel lymph nodes and estimation of their depth using a prototype intraoperative mini gamma-camera in patients with breast cancer. J Nucl Med. 2007;48:623–9.PubMedCrossRef Mathelin C, Salvador S, Huss D, Guyonnet JL. Precise localization of sentinel lymph nodes and estimation of their depth using a prototype intraoperative mini gamma-camera in patients with breast cancer. J Nucl Med. 2007;48:623–9.PubMedCrossRef
13.
go back to reference Schillaci O, D'Errico G, Scafe R, Soluri A, Burgio N, Santagata A, et al. Sentinel node detection with imaging probe. Tumori. 2002;88:S32–5.PubMed Schillaci O, D'Errico G, Scafe R, Soluri A, Burgio N, Santagata A, et al. Sentinel node detection with imaging probe. Tumori. 2002;88:S32–5.PubMed
14.
go back to reference Fujii H, Kitagawa Y, Kitajima M, Kubo A. Sentinel nodes of malignancies originating in the alimentary tract. Ann Nucl Med. 2004;18:1–12.PubMedCrossRef Fujii H, Kitagawa Y, Kitajima M, Kubo A. Sentinel nodes of malignancies originating in the alimentary tract. Ann Nucl Med. 2004;18:1–12.PubMedCrossRef
15.
go back to reference Luini A, Zurrida S, Galimberti V, Paganelli G. Radioguided surgery of occult breast lesions. Eur J Cancer. 1998;34:204–5.PubMedCrossRef Luini A, Zurrida S, Galimberti V, Paganelli G. Radioguided surgery of occult breast lesions. Eur J Cancer. 1998;34:204–5.PubMedCrossRef
16.
go back to reference van Rijk MC, Tanis PJ, Nieweg OE, Loo CE, Valdés-Olmos RA, Olenburg HSA, et al. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer. Ann Surg Oncol. 2006;14:627–32.PubMedCrossRef van Rijk MC, Tanis PJ, Nieweg OE, Loo CE, Valdés-Olmos RA, Olenburg HSA, et al. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer. Ann Surg Oncol. 2006;14:627–32.PubMedCrossRef
17.
go back to reference Intra M, De Cicco C, Gentilini O, Luini A, Paganelli G. Radioguided localisation (ROLL) of non-palpable breast lesions and simultaneous sentinel lymph node biopsy (SNOLL): the experience of the European Institute of Oncology. Eur J Nucl Med Mol Imaging. 2007;34:957–8.PubMedCrossRef Intra M, De Cicco C, Gentilini O, Luini A, Paganelli G. Radioguided localisation (ROLL) of non-palpable breast lesions and simultaneous sentinel lymph node biopsy (SNOLL): the experience of the European Institute of Oncology. Eur J Nucl Med Mol Imaging. 2007;34:957–8.PubMedCrossRef
18.
go back to reference Rubello D, Fig LM, Casara D, Piotto A, Boni G, Pelizzo MR, et al. Radioguided surgery of parathyroid adenomas and recurrent thyroid cancer using the “low sestamibi dose” protocol. Cancer Biother Radiopharm. 2006;21:194–205.PubMedCrossRef Rubello D, Fig LM, Casara D, Piotto A, Boni G, Pelizzo MR, et al. Radioguided surgery of parathyroid adenomas and recurrent thyroid cancer using the “low sestamibi dose” protocol. Cancer Biother Radiopharm. 2006;21:194–205.PubMedCrossRef
19.
go back to reference Goldstein RE, Billheimer D, Martin WH, Richards K. Sestamibi scanning and minimally invasive radioguided parathyroidectomy without intraoperative parathyroid hormone measurement. Ann Surg. 2003;237:722–30.PubMedCrossRef Goldstein RE, Billheimer D, Martin WH, Richards K. Sestamibi scanning and minimally invasive radioguided parathyroidectomy without intraoperative parathyroid hormone measurement. Ann Surg. 2003;237:722–30.PubMedCrossRef
20.
go back to reference Rosa C, Cossard D, Biandrate F, Campagnoni AP, Pandolfi R, Piccolini M, et al. Merkel cell carcinoma: a report of two cases. Chir Ital. 2006;58:785–91.PubMed Rosa C, Cossard D, Biandrate F, Campagnoni AP, Pandolfi R, Piccolini M, et al. Merkel cell carcinoma: a report of two cases. Chir Ital. 2006;58:785–91.PubMed
21.
go back to reference Barros A, Cardoso MA, Sheng PY, Costa PA, Pelizon C. Radioguided localisation of non-palpable breast lesions and simultaneous sentinel lymph node mapping. Eur J Nucl Med. 2002;29:1561–5.CrossRef Barros A, Cardoso MA, Sheng PY, Costa PA, Pelizon C. Radioguided localisation of non-palpable breast lesions and simultaneous sentinel lymph node mapping. Eur J Nucl Med. 2002;29:1561–5.CrossRef
22.
go back to reference Snider HG, Morrison DG. Intraoperative ultrasound localization of nonpalpable breast lesions. Ann Surg Oncol. 1999;6:308–14.PubMedCrossRef Snider HG, Morrison DG. Intraoperative ultrasound localization of nonpalpable breast lesions. Ann Surg Oncol. 1999;6:308–14.PubMedCrossRef
23.
go back to reference Bennett IC, Greenslade J, Chiam H. Intraoperative ultrasound-guided excision of nonpalpable breast lesions. World J Surg. 2005;23:369–74.CrossRef Bennett IC, Greenslade J, Chiam H. Intraoperative ultrasound-guided excision of nonpalpable breast lesions. World J Surg. 2005;23:369–74.CrossRef
24.
go back to reference Rampaul RS, Bagnall M, Burrell H, Pinder SE, Evans AJ, Macmillan RD. Randomized clinical trial comparing radioisotope occult lesion localization and wire-guided excision for biopsy of occult breast lesions. Br J Surg. 2004;91:1575–7.PubMedCrossRef Rampaul RS, Bagnall M, Burrell H, Pinder SE, Evans AJ, Macmillan RD. Randomized clinical trial comparing radioisotope occult lesion localization and wire-guided excision for biopsy of occult breast lesions. Br J Surg. 2004;91:1575–7.PubMedCrossRef
25.
go back to reference Patel A, Pain SJ, Britton P, Sinnatambt R, Warren R, Bobrow L, et al. Radioguided occult lesion localisation (ROLL) and sentinel node biopsy for impalpable invasive breast cancer. Eur J Surg Oncol. 2004;30:918–23.PubMedCrossRef Patel A, Pain SJ, Britton P, Sinnatambt R, Warren R, Bobrow L, et al. Radioguided occult lesion localisation (ROLL) and sentinel node biopsy for impalpable invasive breast cancer. Eur J Surg Oncol. 2004;30:918–23.PubMedCrossRef
Metadata
Title
Radioguided occult lesion localisation in breast cancer using an intraoperative portable gamma camera: first results
Authors
P. Paredes
S. Vidal-Sicart
G. Zanón
N. Roé
S. Rubí
S. Lafuente
J. Pavía
F. Pons
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 2/2008
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-007-0640-x

Other articles of this Issue 2/2008

European Journal of Nuclear Medicine and Molecular Imaging 2/2008 Go to the issue

Society communications

Society communications