The aim of this study was to determine ovarian dose, effective dose and associated radiogenic risks from hysterosalpingography (HSG), and to provide data for the estimation of radiogenic risks related to HSG studies performed in any laboratory. The fluoroscopy time, number of radiographs taken and entrance surface dose were measured in a series of 78 consecutive patients undergoing HSG as part of their infertility work-up. Organ-dose values per radiograph and per minute of fluoroscopy were separately determined using an anthropomorphic phantom and thermoluminescence dosimetry. The radiogenic risk for deleterious effects on a possible future embryo and the radiogenic risk for cancer induction on the patient undergoing HSG were estimated. The average HSG procedure in our laboratory involves a mean fluoroscopic time of 0.3 min and a mean number of radiographs of 3.2. The dose to female gonads from an average HSG procedure was 2.7 mGy and the patient effective dose was 1.2 mSv. The risk for radiogenic anomalies in a future embryo of the woman undergoing an average HSG procedure and the risk for radiogenic fatal cancer induction in the exposed woman were estimated to be less than 10–3 of the correspondent nominal risks. Radiation risks from a typical HSG are low, but they may be elevated if fluoroscopic and/or radiographic exposures are prolonged for any reason. Present data allow the estimation of radiogenic risks associated with HSG procedures performed in other laboratories with use of different equipment, screening time and number of radiographs taken.
Literature
1.
go back to reference Collins JI, Woodward PJ (1995) Radiological evaluation of infertility. Semin Ultrasound CT 16:304–316CrossRef Collins JI, Woodward PJ (1995) Radiological evaluation of infertility. Semin Ultrasound CT 16:304–316CrossRef
2.
go back to reference Ubeda B, Paraira M, Alert E, Abuin RA (2001) Hysterosalpingography: spectrum of normal variants and nonpathologic findings. Am J Roentgenol 177:131–135CrossRef Ubeda B, Paraira M, Alert E, Abuin RA (2001) Hysterosalpingography: spectrum of normal variants and nonpathologic findings. Am J Roentgenol 177:131–135CrossRef
3.
go back to reference Maubon AJ, Degraef M, Boncoeur-Martel MP, Rouanet JP (2001) Interventional radiology in female infertility: technique and role. Eur Radiol 11:771–778CrossRefPubMed Maubon AJ, Degraef M, Boncoeur-Martel MP, Rouanet JP (2001) Interventional radiology in female infertility: technique and role. Eur Radiol 11:771–778CrossRefPubMed
4.
go back to reference Ott DJ, Fayez JA (1991) Hysterosalpingography. Urban and Schwarzenberg, Baltimore Ott DJ, Fayez JA (1991) Hysterosalpingography. Urban and Schwarzenberg, Baltimore
5.
go back to reference Karande VC, Levrant SG, Pratt DE, Morris RS, Balin MS, Gleicher N (1997) What is the radiation exposure to patients during a gynaecoradiologic procedure? Fertil Steril 67:401–403CrossRefPubMed Karande VC, Levrant SG, Pratt DE, Morris RS, Balin MS, Gleicher N (1997) What is the radiation exposure to patients during a gynaecoradiologic procedure? Fertil Steril 67:401–403CrossRefPubMed
6.
go back to reference Hedgpeth PL, Thurmond AS, Fry R, Schmidgall JR, Rosch J (1991) Radiographic fallopian tube recanalization: absorbed ovarian radiation dose. Radiology 180:121–122CrossRefPubMed Hedgpeth PL, Thurmond AS, Fry R, Schmidgall JR, Rosch J (1991) Radiographic fallopian tube recanalization: absorbed ovarian radiation dose. Radiology 180:121–122CrossRefPubMed
7.
go back to reference Fife IAJ, Wilson DJ, Lewis CA (1994) Entrance surface and ovarian doses in hysterosalpingography. Br J Radiol 67:860–863CrossRefPubMed Fife IAJ, Wilson DJ, Lewis CA (1994) Entrance surface and ovarian doses in hysterosalpingography. Br J Radiol 67:860–863CrossRefPubMed
8.
go back to reference Fernandez JM, Vano E, Guibelalde E (1996) Patient doses in hysterosalpingography. Br J Radiol 69:751–754CrossRefPubMed Fernandez JM, Vano E, Guibelalde E (1996) Patient doses in hysterosalpingography. Br J Radiol 69:751–754CrossRefPubMed
9.
go back to reference Nakamura K, Ishiguchi T, Maekoshi H, Ando Y, Tsuzaka M, Tamiya T, Suganuma N, Ishigaki T (1996) Selective fallopian tube catheterization in female infertility: clinical results and absorbed radiation dose. Eur Radiol 6:465–469CrossRefPubMed Nakamura K, Ishiguchi T, Maekoshi H, Ando Y, Tsuzaka M, Tamiya T, Suganuma N, Ishigaki T (1996) Selective fallopian tube catheterization in female infertility: clinical results and absorbed radiation dose. Eur Radiol 6:465–469CrossRefPubMed
10.
go back to reference Gregan ACM, Peach D, McHugo JM (1998) Patient dosimetry in hysterosalpingography: a comparative study. Br J Radiol 71:1058–1061CrossRefPubMed Gregan ACM, Peach D, McHugo JM (1998) Patient dosimetry in hysterosalpingography: a comparative study. Br J Radiol 71:1058–1061CrossRefPubMed
11.
go back to reference Papaioannou S, Afnan M, Coomarasamy A, Ola B, Hammadieh N, Temperton DH, McHugo JM, Sharif K (2002) Long term safety of fluoroscopically guided selective salpingography and tubal catheterization. Hum Reprod 17:370–372CrossRefPubMed Papaioannou S, Afnan M, Coomarasamy A, Ola B, Hammadieh N, Temperton DH, McHugo JM, Sharif K (2002) Long term safety of fluoroscopically guided selective salpingography and tubal catheterization. Hum Reprod 17:370–372CrossRefPubMed
12.
go back to reference Huda W, Sandison GA (1984) Estimation of mean organ doses in diagnostic radiology from rando phantom measurements. Health Phys 47:463–467PubMed Huda W, Sandison GA (1984) Estimation of mean organ doses in diagnostic radiology from rando phantom measurements. Health Phys 47:463–467PubMed
13.
go back to reference Czechowski J, Janeczek J, Kelly G, Johansen J (2001) Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses. Eur Radiol 11:711–713CrossRefPubMed Czechowski J, Janeczek J, Kelly G, Johansen J (2001) Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses. Eur Radiol 11:711–713CrossRefPubMed
14.
go back to reference Marshall NW, Shehu G, Marsh D, Faulkner K, Malone J, Dewhurst K (2001) Effective dose in Albanian direct chest fluoroscopy. Eur Radiol 11:705–710CrossRefPubMed Marshall NW, Shehu G, Marsh D, Faulkner K, Malone J, Dewhurst K (2001) Effective dose in Albanian direct chest fluoroscopy. Eur Radiol 11:705–710CrossRefPubMed
15.
go back to reference Perisinakis K, Theocharopoulos N, Karkavitsas N, Damilakis J (2002) Patient effective radiation dose and associated detriment risk from transmission scans using153Gd line sources in cardiac SPECT studies. Health Phys 83:66–74CrossRefPubMed Perisinakis K, Theocharopoulos N, Karkavitsas N, Damilakis J (2002) Patient effective radiation dose and associated detriment risk from transmission scans using153Gd line sources in cardiac SPECT studies. Health Phys 83:66–74CrossRefPubMed
16.
go back to reference Damilakis J, Perisinakis K, Prassopoulos P, Dimivasili E, Varveris H, Gourtsoyiannis N (2002) Conceptus radiation dose and risk from chest screen-film radiography. Eur Radiol DOI 10.1007/s00330–002–1352-z Damilakis J, Perisinakis K, Prassopoulos P, Dimivasili E, Varveris H, Gourtsoyiannis N (2002) Conceptus radiation dose and risk from chest screen-film radiography. Eur Radiol DOI 10.1007/s00330–002–1352-z
17.
go back to reference ICRP 60 (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP, vol 21, pp 1–3. Pergamon Press, Oxford ICRP 60 (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP, vol 21, pp 1–3. Pergamon Press, Oxford
18.
go back to reference Bo WJ, Wolfman NT, Krueger WA, Carr JJ, Bowden RL, Meschan I (1998) Basic atlas of sectional anatomy with correlated imaging, 3rd edn. Saunders, Philadelphia Bo WJ, Wolfman NT, Krueger WA, Carr JJ, Bowden RL, Meschan I (1998) Basic atlas of sectional anatomy with correlated imaging, 3rd edn. Saunders, Philadelphia
19.
go back to reference Hart D, Jones DG, Wall BF (1994) Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements. NRPB-R262, National Radiological Protection Board Hart D, Jones DG, Wall BF (1994) Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements. NRPB-R262, National Radiological Protection Board
20.
go back to reference Le Heron JC (1995) XDOSE, Ministry of Health, National Radiation Laboratory, Christchurch, New Zealand Le Heron JC (1995) XDOSE, Ministry of Health, National Radiation Laboratory, Christchurch, New Zealand
21.
go back to reference National Research Council (1990) Health effects exposure to low levels of ionizing radiation. BEIR V, National Academy Press, Washington DC National Research Council (1990) Health effects exposure to low levels of ionizing radiation. BEIR V, National Academy Press, Washington DC
22.
go back to reference National Radiological Protection Board (NRPB) (1994) Estimates of radiation detriment in a UK population. NRPB R260. HMSO Publications center, Chilton, UK National Radiological Protection Board (NRPB) (1994) Estimates of radiation detriment in a UK population. NRPB R260. HMSO Publications center, Chilton, UK
23.
go back to reference National Council on Radiation Protection and Measurements (NCRP) (1987) Ionizing radiation exposure of the population in the United States. NCRP Report no. 93. NCRP publications, Bethesda, Maryland National Council on Radiation Protection and Measurements (NCRP) (1987) Ionizing radiation exposure of the population in the United States. NCRP Report no. 93. NCRP publications, Bethesda, Maryland
24.
go back to reference National Radiological Protection Board (NRPB) (1999) Ionising radiation exposure of the UK population: 1999 review. NRPB R311. HMSO Publications Center, Chilton, UK National Radiological Protection Board (NRPB) (1999) Ionising radiation exposure of the UK population: 1999 review. NRPB R311. HMSO Publications Center, Chilton, UK
25.
go back to reference Hall EJ (1994) Hereditary effects of radiation. In: Hall EJ (ed) Radiobiology for the radiologist. Lippincott, Philadelphia Hall EJ (1994) Hereditary effects of radiation. In: Hall EJ (ed) Radiobiology for the radiologist. Lippincott, Philadelphia
26.
go back to reference Jongen VHWM, Collins JMP, Lubbers JA, van Selm M (2001) Unsuspected early pregnancy at hysterosalpingography. Fertil Steril 76:610–611CrossRefPubMed Jongen VHWM, Collins JMP, Lubbers JA, van Selm M (2001) Unsuspected early pregnancy at hysterosalpingography. Fertil Steril 76:610–611CrossRefPubMed
27.
go back to reference Wiesner W, Ruehm SG, Bongartz G, Kaim A, Reese E, De Geyter C (2001) Three-dimensional dynamic MR hysterosalpingography: a preliminary report. Eur Radiol 11:1439–1444CrossRefPubMed Wiesner W, Ruehm SG, Bongartz G, Kaim A, Reese E, De Geyter C (2001) Three-dimensional dynamic MR hysterosalpingography: a preliminary report. Eur Radiol 11:1439–1444CrossRefPubMed
Metadata
Title
Radiogenic risks from hysterosalpingography
Authors
Kostas Perisinakis
John Damilakis
John Grammatikakis
Nicholas Theocharopoulos
Nicholas Gourtsoyiannis
Publication date
01-07-2003
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 7/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-002-1809-0

Other articles of this Issue 7/2003

European Radiology 7/2003 Go to the issue

Interpretation Corner

Knee trauma (2003:7a)