Skip to main content
Top
Published in: Molecular Imaging and Biology 2/2019

Open Access 01-04-2019 | Research Article

Quantitative Intensity Harmonization of Dopamine Transporter SPECT Images Using Gamma Mixture Models

Authors: Alberto Llera, Ismael Huertas, Pablo Mir, Christian F. Beckmann

Published in: Molecular Imaging and Biology | Issue 2/2019

Login to get access

Abstract

Purpose

Differences in site, device, and/or settings may cause large variations in the intensity profile of dopamine transporter (DAT) single-photon emission computed tomography (SPECT) images. However, the current standard to evaluate these images, the striatal binding ratio (SBR), does not efficiently account for this heterogeneity and the assessment can be unequivalent across distinct acquisition pipelines. In this work, we present a voxel-based automated approach to intensity normalize such type of data that improves on cross-session interpretation.

Procedures

The normalization method consists of a reparametrization of the voxel values based on the cumulative density function (CDF) of a Gamma distribution modeling the specific region intensity. The harmonization ability was tested in 1342 SPECT images from the PPMI repository, acquired with 7 distinct gamma camera models and at 24 different sites. We compared the striatal quantification across distinct cameras for raw intensities, SBR values, and after applying the Gamma CDF (GDCF) harmonization. As a proof-of-concept, we evaluated the impact of GCDF normalization in a classification task between controls and Parkinson disease patients.

Results

Raw striatal intensities and SBR values presented significant differences across distinct camera models. We demonstrate that GCDF normalization efficiently alleviated these differences in striatal quantification and with values constrained to a fixed interval [0, 1]. Also, our method allowed a fully automated image assessment that provided maximal classification ability, given by an area under the curve (AUC) of AUC = 0.94 when used mean regional variables and AUC = 0.98 when used voxel-based variables.

Conclusion

The GCDF normalization method is useful to standardize the intensity of DAT SPECT images in an automated fashion and enables the development of unbiased algorithms using multicenter datasets. This method may constitute a key pre-processing step in the analysis of this type of images.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tatsch K, Poepperl G (2013) Nigrostriatal dopamine terminal imaging with dopamine transporter SPECT: an update. J Nucl Med 54:1331–1338CrossRefPubMed Tatsch K, Poepperl G (2013) Nigrostriatal dopamine terminal imaging with dopamine transporter SPECT: an update. J Nucl Med 54:1331–1338CrossRefPubMed
2.
go back to reference Booij J, Teune LK, Verberne HJ (2012) The role of molecular imaging in the differential diagnosis of parkinsonism. Q J Nucl Med Mol Imaging 56:17–26PubMed Booij J, Teune LK, Verberne HJ (2012) The role of molecular imaging in the differential diagnosis of parkinsonism. Q J Nucl Med Mol Imaging 56:17–26PubMed
3.
go back to reference Djang DS, Janssen MJ, Bohnen N et al (2012) SNM practice guideline for dopamine transporter imaging with 123I-ioflupane SPECT 1.0. J Nucl Med 53:154–163CrossRefPubMed Djang DS, Janssen MJ, Bohnen N et al (2012) SNM practice guideline for dopamine transporter imaging with 123I-ioflupane SPECT 1.0. J Nucl Med 53:154–163CrossRefPubMed
4.
go back to reference Badiavas K, Molyvda E, Iakovou I, Tsolaki M, Psarrakos K, Karatzas N (2011) SPECT imaging evaluation in movement disorders: far beyond visual assessment. Eur J Nucl Med Mol Imaging 38:764–773CrossRefPubMed Badiavas K, Molyvda E, Iakovou I, Tsolaki M, Psarrakos K, Karatzas N (2011) SPECT imaging evaluation in movement disorders: far beyond visual assessment. Eur J Nucl Med Mol Imaging 38:764–773CrossRefPubMed
5.
go back to reference Varrone A, Dickson JC, Tossici-Bolt L, Sera T, Asenbaum S, Booij J, Kapucu OL, Kluge A, Knudsen GM, Koulibaly PM, Nobili F, Pagani M, Sabri O, Vander Borght T, van Laere K, Tatsch K (2013) European multicentre database of healthy controls for [123I]FP-CIT SPECT (ENC-DAT): age-related effects, gender differences and evaluation of different methods of analysis. Eur J Nucl Med Mol Imaging 40:213–227CrossRefPubMed Varrone A, Dickson JC, Tossici-Bolt L, Sera T, Asenbaum S, Booij J, Kapucu OL, Kluge A, Knudsen GM, Koulibaly PM, Nobili F, Pagani M, Sabri O, Vander Borght T, van Laere K, Tatsch K (2013) European multicentre database of healthy controls for [123I]FP-CIT SPECT (ENC-DAT): age-related effects, gender differences and evaluation of different methods of analysis. Eur J Nucl Med Mol Imaging 40:213–227CrossRefPubMed
6.
go back to reference Tossici-Bolt L, Dickson JC, Sera T, de Nijs R, Bagnara MC, Jonsson C, Scheepers E, Zito F, Seese A, Koulibaly PM, Kapucu OL, Koole M, Raith M, George J, Lonsdale MN, Münzing W, Tatsch K, Varrone A (2011) Calibration of gamma camera systems for a multicentre European [123I]FP-CIT SPECT normal database. Eur J Nucl Med Mol Imaging 38:1529–1540CrossRefPubMed Tossici-Bolt L, Dickson JC, Sera T, de Nijs R, Bagnara MC, Jonsson C, Scheepers E, Zito F, Seese A, Koulibaly PM, Kapucu OL, Koole M, Raith M, George J, Lonsdale MN, Münzing W, Tatsch K, Varrone A (2011) Calibration of gamma camera systems for a multicentre European [123I]FP-CIT SPECT normal database. Eur J Nucl Med Mol Imaging 38:1529–1540CrossRefPubMed
7.
go back to reference Buchert R, Kluge A, Tossici-Bolt L, Dickson J, Bronzel M, Lange C, Asenbaum S, Booij J, Atay Kapucu LÖ, Svarer C, Koulibaly PM, Nobili F, Pagani M, Sabri O, Sera T, Tatsch K, Vander Borght T, van Laere K, Varrone A, Iida H (2016) Reduction in camera-specific variability in [123I]FP-CIT SPECT outcome measures by image reconstruction optimized for multisite settings: impact on age-dependence of the specific binding ratio in the ENC-DAT database of healthy controls. Eur J Nucl Med Mol Imaging 43:1323–1336CrossRefPubMed Buchert R, Kluge A, Tossici-Bolt L, Dickson J, Bronzel M, Lange C, Asenbaum S, Booij J, Atay Kapucu LÖ, Svarer C, Koulibaly PM, Nobili F, Pagani M, Sabri O, Sera T, Tatsch K, Vander Borght T, van Laere K, Varrone A, Iida H (2016) Reduction in camera-specific variability in [123I]FP-CIT SPECT outcome measures by image reconstruction optimized for multisite settings: impact on age-dependence of the specific binding ratio in the ENC-DAT database of healthy controls. Eur J Nucl Med Mol Imaging 43:1323–1336CrossRefPubMed
9.
go back to reference Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens TEJ, Johansen-Berg H, Bannister PR, de Luca M, Drobnjak I, Flitney DE, Niazy RK, Saunders J, Vickers J, Zhang Y, de Stefano N, Brady JM, Matthews PM (2004) Advances in functional and structural MR image analysis and implementation as FSL. NeuroImage 23(Suppl 1):S208–S219CrossRef Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens TEJ, Johansen-Berg H, Bannister PR, de Luca M, Drobnjak I, Flitney DE, Niazy RK, Saunders J, Vickers J, Zhang Y, de Stefano N, Brady JM, Matthews PM (2004) Advances in functional and structural MR image analysis and implementation as FSL. NeuroImage 23(Suppl 1):S208–S219CrossRef
10.
go back to reference Woolrich MW, Jbabdi S, Patenaude B, Chappell M, Makni S, Behrens T, Beckmann C, Jenkinson M, Smith SM (2009) Bayesian analysis of neuroimaging data in FSL. NeuroImage 45:S173–S186CrossRefPubMed Woolrich MW, Jbabdi S, Patenaude B, Chappell M, Makni S, Behrens T, Beckmann C, Jenkinson M, Smith SM (2009) Bayesian analysis of neuroimaging data in FSL. NeuroImage 45:S173–S186CrossRefPubMed
11.
go back to reference Garcia-Gomez FJ, Garcia-Solis D, Luis-Simon FJ et al (2013) Elaboration of the SPM template for the standardization of SPECT images with Jenkinson M, Beckmann CF, Behrens TE -Ioflupane. Rev Esp Med Nucl Imagen Mol 32:350–356PubMed Garcia-Gomez FJ, Garcia-Solis D, Luis-Simon FJ et al (2013) Elaboration of the SPM template for the standardization of SPECT images with Jenkinson M, Beckmann CF, Behrens TE -Ioflupane. Rev Esp Med Nucl Imagen Mol 32:350–356PubMed
12.
go back to reference Llera A, Vidaurre D, Pruim RHR, Beckmann CF (2016) Variational mixture models with gamma or inverse-gamma components. ArXiv e-prints Volume 16072016 Llera A, Vidaurre D, Pruim RHR, Beckmann CF (2016) Variational mixture models with gamma or inverse-gamma components. ArXiv e-prints Volume 16072016
13.
14.
go back to reference Poldrack RA, Baker CI, Durnez J, Gorgolewski KJ, Matthews PM, Munafò MR, Nichols TE, Poline JB, Vul E, Yarkoni T (2017) Scanning the horizon: towards transparent and reproducible neuroimaging research. Nat Rev Neurosci 18:115–126CrossRefPubMed Poldrack RA, Baker CI, Durnez J, Gorgolewski KJ, Matthews PM, Munafò MR, Nichols TE, Poline JB, Vul E, Yarkoni T (2017) Scanning the horizon: towards transparent and reproducible neuroimaging research. Nat Rev Neurosci 18:115–126CrossRefPubMed
15.
go back to reference Brahim A, Gorriz JM, Ramirez J, Khedher L (2014) Linear intensity normalization of DaTSCAN images using mean square error and a model-based clustering approach. Stud Health Technol Inform 207:251–260PubMed Brahim A, Gorriz JM, Ramirez J, Khedher L (2014) Linear intensity normalization of DaTSCAN images using mean square error and a model-based clustering approach. Stud Health Technol Inform 207:251–260PubMed
16.
go back to reference Brahim A, Ramirez J, Gorriz JM et al (2015) Comparison between different intensity normalization methods in variational mixture models with gamma or inverse-gamma components—ioflupane imaging for the automatic detection of parkinsonism. PLoS One 10:e0130274CrossRefPubMedPubMedCentral Brahim A, Ramirez J, Gorriz JM et al (2015) Comparison between different intensity normalization methods in variational mixture models with gamma or inverse-gamma components—ioflupane imaging for the automatic detection of parkinsonism. PLoS One 10:e0130274CrossRefPubMedPubMedCentral
17.
go back to reference Salas-Gonzalez D, Gorriz JM, Ramirez J, Illan IA, Lang EW (2013) Linear intensity normalization of FP-CIT SPECT brain images using the alpha-stable distribution. NeuroImage 65:449–455CrossRefPubMed Salas-Gonzalez D, Gorriz JM, Ramirez J, Illan IA, Lang EW (2013) Linear intensity normalization of FP-CIT SPECT brain images using the alpha-stable distribution. NeuroImage 65:449–455CrossRefPubMed
Metadata
Title
Quantitative Intensity Harmonization of Dopamine Transporter SPECT Images Using Gamma Mixture Models
Authors
Alberto Llera
Ismael Huertas
Pablo Mir
Christian F. Beckmann
Publication date
01-04-2019
Publisher
Springer International Publishing
Published in
Molecular Imaging and Biology / Issue 2/2019
Print ISSN: 1536-1632
Electronic ISSN: 1860-2002
DOI
https://doi.org/10.1007/s11307-018-1217-8

Other articles of this Issue 2/2019

Molecular Imaging and Biology 2/2019 Go to the issue