Quantitative evaluation of skin shrinkage associated with non-invasive skin tightening: a simple method for reproducible linear measurement using microtattoos

Authors: Murad Alam, Marisa Pongprutthipan, Shivani Nanda, Natalie A. Kim, Jillian H. Swary, Wanjarus Roongpisuthipong, Arielle N. Kauvar, Alexandra Weil, Sanjana Iyengar, Brian R. Chen, Jelena Vasic, Amanda Maisel, Dennis P. West, Michael Nodzenksi, Emir Veledar, Emily Poon

Published in: Lasers in Medical Science | Issue 4/2019

Login to get access

Abstract

Non-invasive skin-tightening devices can induce thermal denaturation and skin shrinkage via externally applied radiofrequency emissions or high-frequency ultrasound. Therefore, the purpose of this study is to develop and test a method for measurement of skin reduction associated with application of such energy devices. Twenty-five healthy participants with mild to moderate skin laxity of the arms were enrolled. Pinpoint microtattoos were placed at each of the treatment sites to delineate two 6 × 12 cm rectangles per subject. A non-stretchable filament, tape and marking pen apparatus was used to measure the size of each rectangle before treatment and at follow-up visit by two blinded investigators. After randomization, one side received a single pass with a radiofrequency device (6.78 MHz), while the contralateral side received multiple passes. Participants underwent two treatment sessions to each side 2 weeks apart, and returned for follow-up 4 weeks after the second treatment. Length and area measurement were analyzed to assess precision and accuracy of measurements and to compare efficacy of treatment between pre- and post-treatment. Concordance correlation coefficients (CCC) demonstrated substantial inter-investigator reliability and precision in length measurements (CCC, 0.94 to 0.98 in pre-treatment; 0.95 to 0.98 in post-treatment). Measurements at the 6-week post-treatment follow-up demonstrated a statistically significant skin reduction in all six of the measured parameters. A simple skin measurement method requiring minimal instrumentation can quantitatively evaluate skin shrinkage associated with non-invasive skin-tightening devices.
Literature
1.
go back to reference Rabe JH, Mamelak AJ, McElgunn PJ, Morison WL, Sauder DN (2006) Photoaging: mechanisms and repair. J Am Acad Dermatol 55:1–19CrossRefPubMed Rabe JH, Mamelak AJ, McElgunn PJ, Morison WL, Sauder DN (2006) Photoaging: mechanisms and repair. J Am Acad Dermatol 55:1–19CrossRefPubMed
2.
go back to reference Makrantonaki E, Zouboulis CC (2007) Molecular mechanisms of skin aging: state of the art. Ann N Y Acad Sci 1119:40–50CrossRefPubMed Makrantonaki E, Zouboulis CC (2007) Molecular mechanisms of skin aging: state of the art. Ann N Y Acad Sci 1119:40–50CrossRefPubMed
3.
go back to reference Morton LM, Dover JS (2014) Foreseeing the future of skin tightening. Dermatol Surg 40(Suppl 12):S199–S202CrossRefPubMed Morton LM, Dover JS (2014) Foreseeing the future of skin tightening. Dermatol Surg 40(Suppl 12):S199–S202CrossRefPubMed
4.
go back to reference Fisher GH, Jacobson LG, Bernstein LJ, Kim KH, Geronemus RG (2005) Nonablative radiofrequency treatment of facial laxity. Dermatol Surg 31:1237–1241 discussion 1241CrossRefPubMed Fisher GH, Jacobson LG, Bernstein LJ, Kim KH, Geronemus RG (2005) Nonablative radiofrequency treatment of facial laxity. Dermatol Surg 31:1237–1241 discussion 1241CrossRefPubMed
5.
go back to reference Carruthers J, Fabi S, Weiss R (2014) Monopolar radiofrequency for skin tightening: our experience and a review of the literature. Dermatol Surg 40(Suppl 12):S168–S173CrossRefPubMed Carruthers J, Fabi S, Weiss R (2014) Monopolar radiofrequency for skin tightening: our experience and a review of the literature. Dermatol Surg 40(Suppl 12):S168–S173CrossRefPubMed
6.
go back to reference Elman M, Vider I, Harth Y, Gottfried V, Shemer A (2010) Non-invasive therapy of wrinkles and lax skin using a novel multisource phase-controlled radio frequency system. J Cosmet Laser Ther 12:81–86CrossRefPubMed Elman M, Vider I, Harth Y, Gottfried V, Shemer A (2010) Non-invasive therapy of wrinkles and lax skin using a novel multisource phase-controlled radio frequency system. J Cosmet Laser Ther 12:81–86CrossRefPubMed
7.
go back to reference Suh DH, Chang KY, Son HC, Ryu JH (2009) Radiofrequency and 585-nm pulsed dye laser treatment of striae distensae: a report of 37 Asian patients. Semin Cutan Med Surg 28:236–243CrossRef Suh DH, Chang KY, Son HC, Ryu JH (2009) Radiofrequency and 585-nm pulsed dye laser treatment of striae distensae: a report of 37 Asian patients. Semin Cutan Med Surg 28:236–243CrossRef
8.
go back to reference Anolik R, Chapas AM, Brightman LA, Geronemus RG (2009) Radiofrequency devices for body shaping: a review and study of 12 patients. Clin Plast Surg 36(2):261–268CrossRef Anolik R, Chapas AM, Brightman LA, Geronemus RG (2009) Radiofrequency devices for body shaping: a review and study of 12 patients. Clin Plast Surg 36(2):261–268CrossRef
9.
go back to reference Hodgkinson DJ (2009) Clinical applications of radiofrequency: nonsurgical skin tightening (thermage). Clin Plast Surg 36(2):261–268CrossRefPubMed Hodgkinson DJ (2009) Clinical applications of radiofrequency: nonsurgical skin tightening (thermage). Clin Plast Surg 36(2):261–268CrossRefPubMed
10.
go back to reference Alster TS, Tanzi EL (2012) Noninvasive lifting of arm, thigh, and knee skin with transcutaneous intense focused ultrasound. Dermatol Surg 38:754–759CrossRefPubMed Alster TS, Tanzi EL (2012) Noninvasive lifting of arm, thigh, and knee skin with transcutaneous intense focused ultrasound. Dermatol Surg 38:754–759CrossRefPubMed
11.
go back to reference Blyumin-Karasik M, Rouhani P, Avashia N, Miteva M, Romanelli P, Kaufmann J, Woolery-Lloyd H (2011) Skin tightening of aging upper arms using an infrared light device. Dermatol Surg 37:441–449CrossRefPubMed Blyumin-Karasik M, Rouhani P, Avashia N, Miteva M, Romanelli P, Kaufmann J, Woolery-Lloyd H (2011) Skin tightening of aging upper arms using an infrared light device. Dermatol Surg 37:441–449CrossRefPubMed
12.
go back to reference Fitzpatrick R, Geronemus R, Goldberg D, Kaminer M, Kilmer S, Ruiz-Esparza J (2003) Multicenter study of noninvasive radiofrequency for periorbital tissue tightening. Lasers Surg Med 33:232–242CrossRefPubMed Fitzpatrick R, Geronemus R, Goldberg D, Kaminer M, Kilmer S, Ruiz-Esparza J (2003) Multicenter study of noninvasive radiofrequency for periorbital tissue tightening. Lasers Surg Med 33:232–242CrossRefPubMed
13.
go back to reference Alster TS, Tanzi E (2004) Improvement of neck and cheek laxity with a nonablative radiofrequency device: a lifting experience. Dermatol Surg 30:503–507 discussion 507PubMed Alster TS, Tanzi E (2004) Improvement of neck and cheek laxity with a nonablative radiofrequency device: a lifting experience. Dermatol Surg 30:503–507 discussion 507PubMed
14.
go back to reference Tanaka Y, Tsunemi Y, Kawashima M, Tatewaki N, Nishida H (2014) Treatment of skin laxity using multisource, phase-controlled radiofrequency in Asians: visualized 3-dimensional skin tightening results and increase in elastin density shown through histologic investigation. Dermatol Surg 40:756–762PubMed Tanaka Y, Tsunemi Y, Kawashima M, Tatewaki N, Nishida H (2014) Treatment of skin laxity using multisource, phase-controlled radiofrequency in Asians: visualized 3-dimensional skin tightening results and increase in elastin density shown through histologic investigation. Dermatol Surg 40:756–762PubMed
15.
go back to reference DiBernardo BE (2010) Randomized, blinded split abdomen study evaluating skin shrinkage and skin tightening in laser-assisted liposuction versus liposuction control. Aesthet Surg J 30(4):593–602CrossRefPubMed DiBernardo BE (2010) Randomized, blinded split abdomen study evaluating skin shrinkage and skin tightening in laser-assisted liposuction versus liposuction control. Aesthet Surg J 30(4):593–602CrossRefPubMed
16.
go back to reference Alam M, Sadhwani D, Geisler A, Aslam I, Makin IRS, Schlessinger DI, Disphanurat W, Pongprutthipan M, Voravutinon N, Weil A, Chen BR, West DP, Veledar E, Poon E (2018) Subcutaneous infiltration of carbon dioxide (carboxytherapy) for abdominal fat reduction: a randomized clinical trial. J Am Acad Dermatol 79(2):320–326CrossRefPubMed Alam M, Sadhwani D, Geisler A, Aslam I, Makin IRS, Schlessinger DI, Disphanurat W, Pongprutthipan M, Voravutinon N, Weil A, Chen BR, West DP, Veledar E, Poon E (2018) Subcutaneous infiltration of carbon dioxide (carboxytherapy) for abdominal fat reduction: a randomized clinical trial. J Am Acad Dermatol 79(2):320–326CrossRefPubMed
17.
go back to reference Alam M, Hughart R, Geisler A, Paghdal K, Maisel A, Weil A, West DP, Veledar E, Poon E (2018) Effectiveness of low doses of hyaluronidase to remove hyaluronic acid filler nodules: a randomized clinical trial. JAMA Dermatol 154(7):765–772CrossRefPubMedPubMedCentral Alam M, Hughart R, Geisler A, Paghdal K, Maisel A, Weil A, West DP, Veledar E, Poon E (2018) Effectiveness of low doses of hyaluronidase to remove hyaluronic acid filler nodules: a randomized clinical trial. JAMA Dermatol 154(7):765–772CrossRefPubMedPubMedCentral
18.
go back to reference Alam M, Geisler A, Sadhwani D, Goyal A, Poon E, Nodzenski M, Schaeffer MR, Tung R, Minkis K (2015) Effect of needle size on pain perception in patients treated with botulinum toxin type A injections: a randomized clinical trial. JAMA Dermatol. 151(11):1194–1199CrossRefPubMed Alam M, Geisler A, Sadhwani D, Goyal A, Poon E, Nodzenski M, Schaeffer MR, Tung R, Minkis K (2015) Effect of needle size on pain perception in patients treated with botulinum toxin type A injections: a randomized clinical trial. JAMA Dermatol. 151(11):1194–1199CrossRefPubMed
19.
go back to reference Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRef Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRef
20.
go back to reference Russell K, Schleichert R, Baum B, Villacorta M, Hardigan P, Thomas J, Weiss E (2015) Ultraviolet-fluorescent tattoo facilitates accurate identification of biopsy sites. Dermatol Surg 41(11):1249–1256CrossRefPubMed Russell K, Schleichert R, Baum B, Villacorta M, Hardigan P, Thomas J, Weiss E (2015) Ultraviolet-fluorescent tattoo facilitates accurate identification of biopsy sites. Dermatol Surg 41(11):1249–1256CrossRefPubMed
21.
go back to reference Dierickx CC (2006) The role of deep heating for noninvasive skin rejuvenation. Lasers Surg Med 38:799–807CrossRefPubMed Dierickx CC (2006) The role of deep heating for noninvasive skin rejuvenation. Lasers Surg Med 38:799–807CrossRefPubMed
23.
go back to reference Atiyeh BS, Dibo SA (2009) Nonsurgical nonablative treatment of aging skin: radiofrequency technologies between aggressive marketing and evidence-based efficacy. Aesthet Plast Surg 33:283–294CrossRef Atiyeh BS, Dibo SA (2009) Nonsurgical nonablative treatment of aging skin: radiofrequency technologies between aggressive marketing and evidence-based efficacy. Aesthet Plast Surg 33:283–294CrossRef
24.
go back to reference Sami K, Elshahat A, Moussa M, Abbas A, Mahmoud A (2015) Image analyzer study of the skin in patients with morbid obesity and massive weight loss. Eplasty 15:e4PubMedPubMedCentral Sami K, Elshahat A, Moussa M, Abbas A, Mahmoud A (2015) Image analyzer study of the skin in patients with morbid obesity and massive weight loss. Eplasty 15:e4PubMedPubMedCentral
Metadata
Title
Quantitative evaluation of skin shrinkage associated with non-invasive skin tightening: a simple method for reproducible linear measurement using microtattoos
Authors
Murad Alam
Marisa Pongprutthipan
Shivani Nanda
Natalie A. Kim
Jillian H. Swary
Wanjarus Roongpisuthipong
Arielle N. Kauvar
Alexandra Weil
Sanjana Iyengar
Brian R. Chen
Jelena Vasic
Amanda Maisel
Dennis P. West
Michael Nodzenksi
Emir Veledar
Emily Poon
Publication date
01-06-2019
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 4/2019
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-018-2646-y

Other articles of this Issue 4/2019

Lasers in Medical Science 4/2019 Go to the issue