Abstract

Purpose

To evaluate the central visual field (CVF) with specialized Amsler grid testing methods that include contrast sensitivity evaluation, in an attempt to detect abnormalities not identified with standard methods and to define new patterns of CVF deficits in two different diseases.

Methods

3D computer-automated threshold Amsler grid testing (3D-CTAG) was performed at five levels of contrast in one eye of 37 patients with diabetic macular edema (DME, n = 16) and exudative age-related macular degeneration (AMD, n = 21).

Results

3D-CTAG abnormalities were detected in six patients (16%) who had no abnormalities with conventional Amsler grid testing. DME patients had more foci of CVF deficits (3.56 ± 2.92 defects/eye), than AMD patients (1.24 ± 0.89 defects/eye; P < 0.0002). The shape of the 3D-CTAG abnormality in DME was an inverted cone, while the deficits in AMD were always cylindrical. All eyes showed significant increases in CVF deficit surface area at minimum contrast levels when compared to maximum contrast (295% greater with DME, P < 0.02 and 150% greater with AMD, P < 0.03).

Conclusion

3D-CTAG detected CVF abnormalities not identified with conventional Amsler grid testing in 16% of subjects. Low-contrast conditions elicited a larger defect in both DME (3-fold) and AMD (1.5-fold). DME and AMD have unique 3D-CTAG profiles, enabling diagnostic discrimination. Measuring CVF defects with 3D-CTAG can quantitatively index disease severity and may be useful in longitudinal studies of the natural history of disease, as well as providing a quantitative outcome measure of the response to therapy.
Literature
2.
go back to reference Wall M, Sadun AA (1986) Threshold amsler grid testing: cross-polarizing lenses enhance yield. Arch Ophthalmol 104:520–523PubMed Wall M, Sadun AA (1986) Threshold amsler grid testing: cross-polarizing lenses enhance yield. Arch Ophthalmol 104:520–523PubMed
3.
go back to reference Fink W, Sadun A (2003) Novel 3D computerized threshold Amsler grid test, perimetry update: 207–212, Proceedings of the XVth International Perimetric Society Meeting in Stratford Upon Avon, England, June, 2002, Kugler Publications bv, Amsterdam/New York Fink W, Sadun A (2003) Novel 3D computerized threshold Amsler grid test, perimetry update: 207–212, Proceedings of the XVth International Perimetric Society Meeting in Stratford Upon Avon, England, June, 2002, Kugler Publications bv, Amsterdam/New York
4.
go back to reference Fink W, Sadun A (2004) 3D computer-automated threshold Amsler grid test. J Biomed Opt 9(1):149–153PubMedCrossRef Fink W, Sadun A (2004) 3D computer-automated threshold Amsler grid test. J Biomed Opt 9(1):149–153PubMedCrossRef
5.
go back to reference Nazemi PP, Fink W, Lim JI, Sadun AA (2005) Scotomas of age-related macular degeneration detected and characterized by means of a novel three-dimensional computer-automated visual field test. Retina 25(4):446–453PubMedCrossRef Nazemi PP, Fink W, Lim JI, Sadun AA (2005) Scotomas of age-related macular degeneration detected and characterized by means of a novel three-dimensional computer-automated visual field test. Retina 25(4):446–453PubMedCrossRef
6.
go back to reference Wolfe KA, Sadun AA (1991) Threshold Amsler grid testing in diabetic retinopathy. Graefes Arch Clin Exp Ophthalmol 229:219–223PubMedCrossRef Wolfe KA, Sadun AA (1991) Threshold Amsler grid testing in diabetic retinopathy. Graefes Arch Clin Exp Ophthalmol 229:219–223PubMedCrossRef
7.
go back to reference Nazemi PP, Fink W, Sadun AA, Francis B, Minckler D (2007) Early detection of glaucoma by means of a novel 3D computer-automated visual field test. Br J Ophthalmol 91:1331–1336PubMedCrossRef Nazemi PP, Fink W, Sadun AA, Francis B, Minckler D (2007) Early detection of glaucoma by means of a novel 3D computer-automated visual field test. Br J Ophthalmol 91:1331–1336PubMedCrossRef
8.
go back to reference Fink W, Hsieh AK, Sadun AA (2000) Computer-automated 3-D visual field testing in distinguishing paracentral scotomas of optic neuritis vs AION [ARVO abstract 1643]. Invest Ophthalmol Vis Sci 41:S311 Fink W, Hsieh AK, Sadun AA (2000) Computer-automated 3-D visual field testing in distinguishing paracentral scotomas of optic neuritis vs AION [ARVO abstract 1643]. Invest Ophthalmol Vis Sci 41:S311
9.
go back to reference Fink W, Castano R (2002) Automated objective characterization of visual field defects in 3D [ARVO abstract 240]. Invest Ophthalmol Vis Sci 43 Fink W, Castano R (2002) Automated objective characterization of visual field defects in 3D [ARVO abstract 240]. Invest Ophthalmol Vis Sci 43
10.
go back to reference Zalta A (1990) Normal gray scale displays in the presence of arcuate scotomas in automated threshold perimetry. Ann Ophthalmol 22:87–91PubMed Zalta A (1990) Normal gray scale displays in the presence of arcuate scotomas in automated threshold perimetry. Ann Ophthalmol 22:87–91PubMed
11.
go back to reference Wall M, May D (1987) Threshold Amsler grid testing in maculopathies. Ophthalmology 94(9):1126–1133PubMed Wall M, May D (1987) Threshold Amsler grid testing in maculopathies. Ophthalmology 94(9):1126–1133PubMed
12.
go back to reference Wall M, Collins C, May D (1990) Low-intensity grid improves sensitivity of Amsler grid testing in diabetic patients without background retinopathy. Ann Ophthalmol 22:96–100PubMed Wall M, Collins C, May D (1990) Low-intensity grid improves sensitivity of Amsler grid testing in diabetic patients without background retinopathy. Ann Ophthalmol 22:96–100PubMed
13.
go back to reference Bresnick G (1986) Diabetic macular edema: a review. Ophthalmology 93(7):989–997PubMed Bresnick G (1986) Diabetic macular edema: a review. Ophthalmology 93(7):989–997PubMed
14.
go back to reference Plummer D, Azen S, Freeman W (2000) Scanning laser entopic perimetry for the screening of macular and peripheral retinal disease. Arch Ophthalmol 118:1205–1210PubMed Plummer D, Azen S, Freeman W (2000) Scanning laser entopic perimetry for the screening of macular and peripheral retinal disease. Arch Ophthalmol 118:1205–1210PubMed
15.
go back to reference Brown J, Kylstra J, Mah ML (2000) Entopic perimetry screening for central diabetic scotomas and macular edema. Ophthalmology 107(4):755–759PubMedCrossRef Brown J, Kylstra J, Mah ML (2000) Entopic perimetry screening for central diabetic scotomas and macular edema. Ophthalmology 107(4):755–759PubMedCrossRef
Metadata
Title
Quantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated threshold Amsler grid testing
Authors
Renu V. Jivrajka
Janet K. Kim
Wolfgang Fink
Alfredo A. Sadun
J. Sebag
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 2/2009
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-008-0971-8

Other articles of this Issue 2/2009

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2009 Go to the issue