Quantitative analysis in outcome assessment of instrumented lumbosacral arthrodesis

Authors: Sabina Champain, Christian Mazel, Anca Mitulescu, Wafa Skalli

Published in: European Spine Journal | Issue 8/2007

Login to get access

Abstract

The outcome assessment in instrumented lumbosacral fusion mostly focuses on clinical criteria, complications and scores, with a high variability of imaging means, methods of fusion grading and parameters describing degenerative changes, making comparisons between studies difficult. The aim of this retrospective evaluation was to evaluate the interest of quantified radiographic analysis of lumbar spine in global outcome assessment and to highlight the key biomechanical factors involved. Clinical data and Beaujon–Lassale scores were collected for 49 patients who underwent lumbosacral arthrodesis after prior lumbar discectomy (mean follow-up: 5 years). Sagittal standing and lumbar flexion-extension X-ray films allowed quantifying vertebral, lumbar, pelvic and kinematic parameters of the lumbar spine, which were compared to reference values. Statistics were performed to assess evolution for all variables. At long-term follow-up, 90% of patients presented satisfactory clinical outcomes, associated to normal sagittal alignment; vertebral parameters objectified adjacent level degeneration in four cases (8%). Clinical outcome was correlated (r = 0.8) with fusion that was confirmed in 80% of cases, doubtful in 16% and pseudarthrosis seemed to occur in 4% (2) of cases. In addition to clinical data (outcomes comparable to the literature), quantitative analysis accurately described lumbar spine geometry and kinematics, highlighting parameters related to adjacent level’s degeneration and a significant correlation between clinical outcome and fusion. Furthermore, criteria proposed to quantitatively evaluate fusion from lumbar dynamic radiographs seem to be appropriate and in agreement with surgeon’s qualitative grading in 87% of cases.
Literature
1.
go back to reference Akamaru T, Kawahara N et al (2003) Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis. Spine 28(14):1560–1566PubMedCrossRef Akamaru T, Kawahara N et al (2003) Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis. Spine 28(14):1560–1566PubMedCrossRef
2.
go back to reference Brodsky AE, Kovalsky ES, Khalil MA (1991) Correlation of radiologic assessment of lumbar spine fusions with surgical exploration. Spine 16(Suppl 6):S261–S265PubMedCrossRef Brodsky AE, Kovalsky ES, Khalil MA (1991) Correlation of radiologic assessment of lumbar spine fusions with surgical exploration. Spine 16(Suppl 6):S261–S265PubMedCrossRef
3.
go back to reference Champain S, Benchikh K, Nogier A et al (2006) Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies. Eur Spine J 15(6):982–991PubMedCrossRef Champain S, Benchikh K, Nogier A et al (2006) Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies. Eur Spine J 15(6):982–991PubMedCrossRef
4.
go back to reference Cheung J, Wever DJ, Veldhuizen AG et al (2002) The reliability of quantitative analysis on digital images of the scoliotic spine. Eur Spine J 11:535–542PubMedCrossRef Cheung J, Wever DJ, Veldhuizen AG et al (2002) The reliability of quantitative analysis on digital images of the scoliotic spine. Eur Spine J 11:535–542PubMedCrossRef
5.
go back to reference Chou WY, Hsu CJ, Chang WN et al (2002) Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients. Arch Orthop Trauma Surg 122(1):39–43PubMed Chou WY, Hsu CJ, Chang WN et al (2002) Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients. Arch Orthop Trauma Surg 122(1):39–43PubMed
6.
go back to reference Christensen FB, Laursen M, Gelineck J et al (2001) Interobserver and intraobserver agreement of radiograph interpretation with and without pedicle screw implants: the need for a detailed classification system in posterolateral spinal fusion. Spine 26(5):538–543PubMedCrossRef Christensen FB, Laursen M, Gelineck J et al (2001) Interobserver and intraobserver agreement of radiograph interpretation with and without pedicle screw implants: the need for a detailed classification system in posterolateral spinal fusion. Spine 26(5):538–543PubMedCrossRef
7.
go back to reference Diedrich O, Perlick L, Schmitt O et al (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radioopaque cages. J Spinal Disord 14(6):522–532PubMedCrossRef Diedrich O, Perlick L, Schmitt O et al (2001) Radiographic characteristics on conventional radiographs after posterior lumbar interbody fusion: comparative study between radiotranslucent and radioopaque cages. J Spinal Disord 14(6):522–532PubMedCrossRef
8.
go back to reference Frobin W, Brinckmann P, Leivseth G et al (1996) Precision measurement of segmental motion from flexion-extension radiographs of the lumbar spine. Clin Biomech 11(8):457–465CrossRef Frobin W, Brinckmann P, Leivseth G et al (1996) Precision measurement of segmental motion from flexion-extension radiographs of the lumbar spine. Clin Biomech 11(8):457–465CrossRef
9.
go back to reference Ghiselli G, Wang JC, Hsu WK et al (2004) Adjacent segment degeneration in the lumbar spine. J Bone Joint Surg Am 86-A(7):1497–1503PubMed Ghiselli G, Wang JC, Hsu WK et al (2004) Adjacent segment degeneration in the lumbar spine. J Bone Joint Surg Am 86-A(7):1497–1503PubMed
10.
go back to reference Godde S, Fritsch E, Dienst M et al (2003) Influence of cage geometry on sagittal alignment in instrumented posterior lumbar interbody fusion. Spin 28(15):1693–1699CrossRef Godde S, Fritsch E, Dienst M et al (2003) Influence of cage geometry on sagittal alignment in instrumented posterior lumbar interbody fusion. Spin 28(15):1693–1699CrossRef
11.
go back to reference Goto K, Tajima N, Chosa E et al (2003) Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis). J Orthop Sci 8(4):577–584PubMedCrossRef Goto K, Tajima N, Chosa E et al (2003) Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis). J Orthop Sci 8(4):577–584PubMedCrossRef
12.
go back to reference Graftiaux AG, Wattier B, Gentil P et al (1995) Biomechanical evaluation of different instrumentation for spinal stabilisation. Eur J Orthop Surg Traumatol 5:265–269 Graftiaux AG, Wattier B, Gentil P et al (1995) Biomechanical evaluation of different instrumentation for spinal stabilisation. Eur J Orthop Surg Traumatol 5:265–269
13.
go back to reference Hamill CL, Simmons ED (1997) Interobserver variability in grading lumbar fusions. J Spinal Disord 10(5):387–390PubMedCrossRef Hamill CL, Simmons ED (1997) Interobserver variability in grading lumbar fusions. J Spinal Disord 10(5):387–390PubMedCrossRef
14.
go back to reference Hayes MA, Howard TC, Gruel CL et al (1989) Roentgenographic evaluation of lumbar spine flexion-extension in asymptomatic individuals. Spine 14(3):327–331PubMedCrossRef Hayes MA, Howard TC, Gruel CL et al (1989) Roentgenographic evaluation of lumbar spine flexion-extension in asymptomatic individuals. Spine 14(3):327–331PubMedCrossRef
15.
go back to reference Kant AP, Daum WJ, Dean SM et al (1995) Evaluation of lumbar spine fusion. Plain radiographs versus direct surgical exploration and observation. Spine 20:2313–2317PubMedCrossRef Kant AP, Daum WJ, Dean SM et al (1995) Evaluation of lumbar spine fusion. Plain radiographs versus direct surgical exploration and observation. Spine 20:2313–2317PubMedCrossRef
16.
go back to reference Korovessis P, Papazisis Z, Koureas G et al (2004) Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine 29(7):735–742PubMedCrossRef Korovessis P, Papazisis Z, Koureas G et al (2004) Rigid, semirigid versus dynamic instrumentation for degenerative lumbar spinal stenosis: a correlative radiological and clinical analysis of short-term results. Spine 29(7):735–742PubMedCrossRef
17.
go back to reference Lassale B, Deburge A, Benoist M (1985) Résultat à long terme du traitement chirurgical des sténoses lombaires. Rev Rhum Mal Ostéoartic (52):27–33 Lassale B, Deburge A, Benoist M (1985) Résultat à long terme du traitement chirurgical des sténoses lombaires. Rev Rhum Mal Ostéoartic (52):27–33
18.
go back to reference Lazennec JY, Ramare S, Arafati N et al (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9(1):47–55PubMedCrossRef Lazennec JY, Ramare S, Arafati N et al (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9(1):47–55PubMedCrossRef
19.
go back to reference Legaye J, Hecquet J, Marty C et al (1993) Equilibre sagittal du rachis. Rachis 5(5):215–226 Legaye J, Hecquet J, Marty C et al (1993) Equilibre sagittal du rachis. Rachis 5(5):215–226
20.
go back to reference McAfee PC, Boden SD et al (2001) Symposium: a critical discrepancy —criteria of successful arthrodesis following interbody spinal fusions. Spine 26(3):320–334PubMedCrossRef McAfee PC, Boden SD et al (2001) Symposium: a critical discrepancy —criteria of successful arthrodesis following interbody spinal fusions. Spine 26(3):320–334PubMedCrossRef
21.
go back to reference Mazel Ch (1995) Instrumentation rachidienne flexible Twinflex dans les arthrodeses lombaires et lombosacrées—serie de 114 cas avec un recul minimal de 1 an. Eur J Orthop Surg Traumatol 5:271–277 Mazel Ch (1995) Instrumentation rachidienne flexible Twinflex dans les arthrodeses lombaires et lombosacrées—serie de 114 cas avec un recul minimal de 1 an. Eur J Orthop Surg Traumatol 5:271–277
22.
go back to reference Okuda S, Iwasaki M, Miyauchi A et al (2004) Risk factors for adjacent segment degeneration after PLIF. Spine 29(14):1535–1540PubMedCrossRef Okuda S, Iwasaki M, Miyauchi A et al (2004) Risk factors for adjacent segment degeneration after PLIF. Spine 29(14):1535–1540PubMedCrossRef
23.
go back to reference Ostermann H, Sund R, Seitsalo S et al (2003) Multiple reoperations after lumbar discectomy. Spine 28(6):621–627CrossRef Ostermann H, Sund R, Seitsalo S et al (2003) Multiple reoperations after lumbar discectomy. Spine 28(6):621–627CrossRef
24.
go back to reference Pearcy M, Portek I, Shepherd J (1984) Three-dimensional X-ray analysis of normal movements in the lumbar spine. Spine 9(3):582–587PubMedCrossRef Pearcy M, Portek I, Shepherd J (1984) Three-dimensional X-ray analysis of normal movements in the lumbar spine. Spine 9(3):582–587PubMedCrossRef
25.
go back to reference Pearcy MJ, Bogduk N (1988) Instantaneous axes of rotation of the lumbar intervertebral joints. Spine 13(9):1033–1041PubMedCrossRef Pearcy MJ, Bogduk N (1988) Instantaneous axes of rotation of the lumbar intervertebral joints. Spine 13(9):1033–1041PubMedCrossRef
26.
go back to reference Rajnics P, Pomero V, De Guise J et al (2001) Computer-assisted assessment of spinal sagittal plane radiographs. J Spinal Disord 14:135–142PubMedCrossRef Rajnics P, Pomero V, De Guise J et al (2001) Computer-assisted assessment of spinal sagittal plane radiographs. J Spinal Disord 14:135–142PubMedCrossRef
27.
go back to reference Rillardon L, Levassor N, Guigui P et al (2003) Validation of a tool to measure pelvic and spinal parameters of lumbar and pelvic balance. Rev Chir Orthop Reparatrice Appar Mot 89(3):218–227PubMed Rillardon L, Levassor N, Guigui P et al (2003) Validation of a tool to measure pelvic and spinal parameters of lumbar and pelvic balance. Rev Chir Orthop Reparatrice Appar Mot 89(3):218–227PubMed
28.
go back to reference Santos ER, Goss DG, Morcom RK, Fraser RD et al (2003) Radiologic assessment of interbody fusion using carbon fiber cages. Spine 28(10):997–1001PubMedCrossRef Santos ER, Goss DG, Morcom RK, Fraser RD et al (2003) Radiologic assessment of interbody fusion using carbon fiber cages. Spine 28(10):997–1001PubMedCrossRef
29.
go back to reference Schlegel JD, Smith JA, Schleusener RL (1996) Lumbosacral motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21:970–981PubMedCrossRef Schlegel JD, Smith JA, Schleusener RL (1996) Lumbosacral motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine 21:970–981PubMedCrossRef
30.
go back to reference Schofferman J, Reynolds J, Herzog R et al (2003) Failed back surgery: etiology and diagnostic evaluation. Spine J 3:400–403PubMedCrossRef Schofferman J, Reynolds J, Herzog R et al (2003) Failed back surgery: etiology and diagnostic evaluation. Spine J 3:400–403PubMedCrossRef
31.
go back to reference Shea KG, Stevens PM, Nelson M et al (1998) A comparison of manual versus computer-assisted radiographic measurement. Intraobserver measurement variability for Cobb angles. Spine 23:551–555PubMedCrossRef Shea KG, Stevens PM, Nelson M et al (1998) A comparison of manual versus computer-assisted radiographic measurement. Intraobserver measurement variability for Cobb angles. Spine 23:551–555PubMedCrossRef
32.
go back to reference Siambanes D, Mather S (1998) Comparison of plain radiographs and CT scans in instrumented posterior lumbar interbody fusion. Orthopedics 21(2):165–167PubMed Siambanes D, Mather S (1998) Comparison of plain radiographs and CT scans in instrumented posterior lumbar interbody fusion. Orthopedics 21(2):165–167PubMed
33.
go back to reference Skalli W, Lavaste F (2002) Informatique et modélisation statique et dynamique du rachis. Cahiers d’enseignement de la Sofcot, Chirurgie orthopédique assistée par ordinateur 80:209–221 Skalli W, Lavaste F (2002) Informatique et modélisation statique et dynamique du rachis. Cahiers d’enseignement de la Sofcot, Chirurgie orthopédique assistée par ordinateur 80:209–221
34.
go back to reference Stagnara P, De Mauroy JC, Dran G et al (1982) Reciprocal angulation of vertebral bodies in a sagittal plane: approach to references for evaluation of kyphosis and lordosis. Spine 7(4):335–342PubMedCrossRef Stagnara P, De Mauroy JC, Dran G et al (1982) Reciprocal angulation of vertebral bodies in a sagittal plane: approach to references for evaluation of kyphosis and lordosis. Spine 7(4):335–342PubMedCrossRef
35.
go back to reference Tajima N, Kawano K, Sera K et al (1989) Posterolateral fusion of the lumbar and lumbosacral spine—a review of long term results. Nippon Seikeigeka Gakkai Zasshi 63(4):262–268PubMed Tajima N, Kawano K, Sera K et al (1989) Posterolateral fusion of the lumbar and lumbosacral spine—a review of long term results. Nippon Seikeigeka Gakkai Zasshi 63(4):262–268PubMed
36.
go back to reference Templier A, Skalli W, Diop A et al (1999) Evaluation radiographique quantitative des arthrodèses rachidiennes lombaires: protocole et analyse préliminaire d’une série multicentrique de 119 cas. Rachis 23–37 Templier A, Skalli W, Diop A et al (1999) Evaluation radiographique quantitative des arthrodèses rachidiennes lombaires: protocole et analyse préliminaire d’une série multicentrique de 119 cas. Rachis 23–37
37.
38.
go back to reference Vialle R, Levassor N, Rillardon L et al (2005) Radiographic analysis of the sagittal alignement and balance of the spine in asymptomatic subjects. J Bone Joint Surg Am 87(2):260–267PubMedCrossRef Vialle R, Levassor N, Rillardon L et al (2005) Radiographic analysis of the sagittal alignement and balance of the spine in asymptomatic subjects. J Bone Joint Surg Am 87(2):260–267PubMedCrossRef
39.
go back to reference Wetzel FT, Brustein M, Phillips FM et al (1999) Hardware failure in an unconstrained lumbar pedicle screw system. A 2-year follow-up study. Spine 24(11):1138–1143PubMedCrossRef Wetzel FT, Brustein M, Phillips FM et al (1999) Hardware failure in an unconstrained lumbar pedicle screw system. A 2-year follow-up study. Spine 24(11):1138–1143PubMedCrossRef
Metadata
Title
Quantitative analysis in outcome assessment of instrumented lumbosacral arthrodesis
Authors
Sabina Champain
Christian Mazel
Anca Mitulescu
Wafa Skalli
Publication date
01-08-2007
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 8/2007
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0302-x

Other articles of this Issue 8/2007

European Spine Journal 8/2007 Go to the issue