Abstract

The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.
Literature
1.
go back to reference Vignon P, AitHssain A, François B, Preux PM, Pichon N, Clavel M, Frat JP, Gastinne H: Echocardiographic assessment of pulmonary artery occlusion pressure in ventilated patients: a transesophageal study. Crit Care. 2008, 12: R18-10.1186/cc6792.PubMedPubMedCentralCrossRef Vignon P, AitHssain A, François B, Preux PM, Pichon N, Clavel M, Frat JP, Gastinne H: Echocardiographic assessment of pulmonary artery occlusion pressure in ventilated patients: a transesophageal study. Crit Care. 2008, 12: R18-10.1186/cc6792.PubMedPubMedCentralCrossRef
2.
go back to reference Voga G, Zuran I, Krivec B, Skale R, Pareznik R, Podbregar M: Comparison of clinical and hemodynamic assessment of heart failure in patients with acute myocardial infarction. Zdrav vestn. 1997, 66: 359-363. Voga G, Zuran I, Krivec B, Skale R, Pareznik R, Podbregar M: Comparison of clinical and hemodynamic assessment of heart failure in patients with acute myocardial infarction. Zdrav vestn. 1997, 66: 359-363.
3.
go back to reference Dawson NV, Connors AF, Speroff T, Kemka A, Shaw P, Arkes HR: Hemodynamic assessment in managing the critically ill: is the physician confidence warranted?. Med Decis Making. 1993, 13: 258-266. 10.1177/0272989X9301300314.PubMedCrossRef Dawson NV, Connors AF, Speroff T, Kemka A, Shaw P, Arkes HR: Hemodynamic assessment in managing the critically ill: is the physician confidence warranted?. Med Decis Making. 1993, 13: 258-266. 10.1177/0272989X9301300314.PubMedCrossRef
4.
go back to reference Herman PG, Khan A, Kallman CE, Rojas KA, Carmody DP, Bodenheimer MM: Limited correlation of left ventricular end-diastolic pressure with radiographic assessment of pulmonary hemodynamics. Radiology. 1990, 174: 721-724.PubMedCrossRef Herman PG, Khan A, Kallman CE, Rojas KA, Carmody DP, Bodenheimer MM: Limited correlation of left ventricular end-diastolic pressure with radiographic assessment of pulmonary hemodynamics. Radiology. 1990, 174: 721-724.PubMedCrossRef
5.
go back to reference Staudinger T, Locker GJ, Laczika K, Knapp S, Burgmann H, Wagner A, Weiss K, Zimmerl M, Stoiser B, Frass M: Diagnostic validity of pulmonary artery catheterization for residents at an intensive care unit. J Trauma. 1998, 44: 902-906.PubMedCrossRef Staudinger T, Locker GJ, Laczika K, Knapp S, Burgmann H, Wagner A, Weiss K, Zimmerl M, Stoiser B, Frass M: Diagnostic validity of pulmonary artery catheterization for residents at an intensive care unit. J Trauma. 1998, 44: 902-906.PubMedCrossRef
6.
go back to reference Cholley BP, Vieillard-Baron A, Mebazaa A: Echocardiography in the ICU: time for widespread use!. Intensive Care Med. 2006, 32: 9-10. 10.1007/s00134-005-2833-8.PubMedCrossRef Cholley BP, Vieillard-Baron A, Mebazaa A: Echocardiography in the ICU: time for widespread use!. Intensive Care Med. 2006, 32: 9-10. 10.1007/s00134-005-2833-8.PubMedCrossRef
7.
go back to reference Nagueh SF, Kopelen HA, Zoghbi WA: Feasibility and accuracy of Doppler echocardiographic estimation of pulmonary artery occlusion pressure in the intensive care unit. Am J Cardiol. 1995, 75: 1256-1262. 10.1016/S0002-9149(99)80773-5.PubMedCrossRef Nagueh SF, Kopelen HA, Zoghbi WA: Feasibility and accuracy of Doppler echocardiographic estimation of pulmonary artery occlusion pressure in the intensive care unit. Am J Cardiol. 1995, 75: 1256-1262. 10.1016/S0002-9149(99)80773-5.PubMedCrossRef
8.
go back to reference Boussuges A, Blanc P, Molenat F, Burnet H, Habib G, Sainty JM: Evaluation of left ventricular filling pressure by transthoracic Doppler echocardiography in the intensive care unit. Crit Care Med. 2002, 30: 362-367. 10.1097/00003246-200202000-00016.PubMedCrossRef Boussuges A, Blanc P, Molenat F, Burnet H, Habib G, Sainty JM: Evaluation of left ventricular filling pressure by transthoracic Doppler echocardiography in the intensive care unit. Crit Care Med. 2002, 30: 362-367. 10.1097/00003246-200202000-00016.PubMedCrossRef
9.
go back to reference Yamamuro A, Yoshida K, Hozumi T, Akasaka T, Takagi T, Kaji S, Kawamoto T, Yoshikawa J: Noninvasive evaluation of pulmonary capillary wedge pressure in patients with acute myocardial infarction by deceleration time of pulmonary venous flow velocity in diastole. J Am Coll Cardiol. 1999, 34: 90-94. 10.1016/S0735-1097(99)00191-6.PubMedCrossRef Yamamuro A, Yoshida K, Hozumi T, Akasaka T, Takagi T, Kaji S, Kawamoto T, Yoshikawa J: Noninvasive evaluation of pulmonary capillary wedge pressure in patients with acute myocardial infarction by deceleration time of pulmonary venous flow velocity in diastole. J Am Coll Cardiol. 1999, 34: 90-94. 10.1016/S0735-1097(99)00191-6.PubMedCrossRef
10.
go back to reference Masuyama T, Lee JM, Nagano R, Nariyama K, Yamamoto K, Naito J, Mano T, Kondo H, Hori M, Kamada T: Doppler echocardiographic pulmonary venous flow-velocity pattern for assessment of the hemodynamic profile in acute congestive heart failure. Am Heart J. 1995, 129: 107-113. 10.1016/0002-8703(95)90050-0.PubMedCrossRef Masuyama T, Lee JM, Nagano R, Nariyama K, Yamamoto K, Naito J, Mano T, Kondo H, Hori M, Kamada T: Doppler echocardiographic pulmonary venous flow-velocity pattern for assessment of the hemodynamic profile in acute congestive heart failure. Am Heart J. 1995, 129: 107-113. 10.1016/0002-8703(95)90050-0.PubMedCrossRef
11.
go back to reference Rivas-Gotz C, Manolios M, Thohan V, Nagueh S: Impact of left ventricular ejection fraction on estimation of left ventricular filling pressures using tissue Doppler and flow propagation velocity. Am J Cardiol. 2003, 91: 780-784. 10.1016/S0002-9149(02)03433-1.PubMedCrossRef Rivas-Gotz C, Manolios M, Thohan V, Nagueh S: Impact of left ventricular ejection fraction on estimation of left ventricular filling pressures using tissue Doppler and flow propagation velocity. Am J Cardiol. 2003, 91: 780-784. 10.1016/S0002-9149(02)03433-1.PubMedCrossRef
12.
go back to reference Kuecherer HF, Muhiudeen IA, Kusumoto FM, Lee E, Moulinier LE, Cahalan MK, Schiller NB: Estimation of left atrial pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow. Circulation. 1990, 82: 1127-1139.PubMedCrossRef Kuecherer HF, Muhiudeen IA, Kusumoto FM, Lee E, Moulinier LE, Cahalan MK, Schiller NB: Estimation of left atrial pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow. Circulation. 1990, 82: 1127-1139.PubMedCrossRef
13.
go back to reference Bouhemad B, Nicolas-Robin A, Benois A, Lemaire S, Goarin JP, Rouby JJ: Echocardiographic Doppler assessment of pulmonary capillary wedge pressure in surgical patients with postoperative circulatory shock and acute lung injury. Anesthesiology. 2003, 98: 1091-1100. 10.1097/00000542-200305000-00011.PubMedCrossRef Bouhemad B, Nicolas-Robin A, Benois A, Lemaire S, Goarin JP, Rouby JJ: Echocardiographic Doppler assessment of pulmonary capillary wedge pressure in surgical patients with postoperative circulatory shock and acute lung injury. Anesthesiology. 2003, 98: 1091-1100. 10.1097/00000542-200305000-00011.PubMedCrossRef
14.
go back to reference Combes A, Arnoult F, Trouillet JL: Tissue Doppler imaging estimation of pulmonary artery occlusion pressure in ICU patients. Intensive Care Med. 2004, 30: 75-81. 10.1007/s00134-003-2039-x.PubMedCrossRef Combes A, Arnoult F, Trouillet JL: Tissue Doppler imaging estimation of pulmonary artery occlusion pressure in ICU patients. Intensive Care Med. 2004, 30: 75-81. 10.1007/s00134-003-2039-x.PubMedCrossRef
Metadata
Title
Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?
Author
Gorazd Voga
Publication date
01-04-2008
Publisher
BioMed Central
Published in
Critical Care / Issue 2/2008
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc6831

Other articles of this Issue 2/2008

Critical Care 2/2008 Go to the issue