Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2006

01-10-2006 | Knee

Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques

Authors: Yavuz Kocabey, Omer Taser, John Nyland, Mahmut Nedim Doral, Mehmet Demirhan, David N. M. Caborn, Sezgin Sarban

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 10/2006

Login to get access

Abstract

This in vitro biomechanical study with cyclic loading compared the pullout strength of vertical, horizontal, and oblique sutures used for meniscal lesion repair. Following repair of vertical longitudinal lesions created in bovine medial menisci, three groups of seven specimens (vertical, horizontal, and oblique sutures) underwent cyclic loading in a randomized test order (5 mm/min, cycling between 5 and 50 N at 1 Hz for 100 cycles) prior to load to failure testing (5 mm/min). Displacement did not differ between groups during cyclic or load to failure testing. Construct stiffness during cyclic testing was superior for the oblique suture (6.9 ± 1.5 N/mm, = 0.007) and the vertical suture (6.4 ± 7 N/mm, = 0.03) groups compared to the horizontal suture group (4.4 ± 0.52 N/mm). The oblique suture (171.9 ± 25.9 N, < 0.0001) and the vertical suture (145.9 ± 32.3 N, = 0.001) groups displayed superior load at failure compared to the horizontal suture group (88.8 ± 8.2 N). Construct stiffness during load to failure testing did not differ between groups. Suture rupture was the failure mode for all specimens of the oblique suture group. Suture rupture was the failure mode for 57% (4/7) of the vertical suture group with the remaining specimens (3/7, 43%) failing from intact suture pullout through meniscal tissue. All horizontal suture group specimens failed by intact suture pulling through meniscal tissue. With comparable stiffness during cyclic testing, comparable load at failure as vertical sutures, and less evidence of intact suture pullout through the meniscus, an oblique suture technique may combine the beneficial characteristics of vertical (superior biomechanical strength) and horizontal (ease of application, longer sutures with a tendency to cover a larger meniscal tissue area) suture-repair techniques.
Literature
1.
go back to reference Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10(1):25–29PubMedCrossRef Asik M, Sener N (2002) Failure strength of repair devices versus meniscus suturing techniques. Knee Surg Sports Traumatol Arthrosc 10(1):25–29PubMedCrossRef
2.
3.
go back to reference Barber FA, Stone RG (1985) Meniscal repair. An arthroscopic technique. J Bone Joint Surg Br 67(1):39–41PubMed Barber FA, Stone RG (1985) Meniscal repair. An arthroscopic technique. J Bone Joint Surg Br 67(1):39–41PubMed
4.
go back to reference Boenisch UW, Faber KJ, Ciarelli M, et al. (1999) Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med 27(5):626–631PubMed Boenisch UW, Faber KJ, Ciarelli M, et al. (1999) Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures. Am J Sports Med 27(5):626–631PubMed
5.
go back to reference Borden P, Nyland J, Caborn DNM, Pienkowski D (2003) Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows. Am J Sports Med 31(3):374–378PubMed Borden P, Nyland J, Caborn DNM, Pienkowski D (2003) Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows. Am J Sports Med 31(3):374–378PubMed
6.
go back to reference Henning CE, Clark JR, Lynch MA, et al (1988) Arthroscopic meniscus repair with a posterior incision. Instr Course Lect 37:209–221PubMed Henning CE, Clark JR, Lynch MA, et al (1988) Arthroscopic meniscus repair with a posterior incision. Instr Course Lect 37:209–221PubMed
7.
go back to reference Hsieh HH, Walker PS (1976) Stabilizing mechanisms of the loaded and unloaded knee joint. J Bone Joint Surg Am 58(1):87–93PubMed Hsieh HH, Walker PS (1976) Stabilizing mechanisms of the loaded and unloaded knee joint. J Bone Joint Surg Am 58(1):87–93PubMed
8.
go back to reference Karaoglu S, Duygulu F, Inan M, Baktir A (2002) Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci. Knee Surg Sports Traumatol Arthrosc 10:198–201PubMedCrossRef Karaoglu S, Duygulu F, Inan M, Baktir A (2002) Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci. Knee Surg Sports Traumatol Arthrosc 10:198–201PubMedCrossRef
9.
go back to reference Kohn D, Siebert W (1989) Meniscus suture techniques: a comparative biomechanical cadaver study. Arthroscopy 5(4):324–327PubMedCrossRef Kohn D, Siebert W (1989) Meniscus suture techniques: a comparative biomechanical cadaver study. Arthroscopy 5(4):324–327PubMedCrossRef
10.
go back to reference Kurosawa H, Fukubayashi T, Nakajima H (1980) Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. Clin Orthop 149:283–290PubMed Kurosawa H, Fukubayashi T, Nakajima H (1980) Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. Clin Orthop 149:283–290PubMed
11.
go back to reference MacConaill MA (1950) The movements of bones and joints: the synovial fluid and its assistants. J Bone Joint Surg Br 32(2):244–252PubMed MacConaill MA (1950) The movements of bones and joints: the synovial fluid and its assistants. J Bone Joint Surg Br 32(2):244–252PubMed
12.
go back to reference Post WR, Akers SR, Kish V (1997) Load to failure of common meniscal repair techniques: effects of suture technique and suture material. Arthroscopy 13(6):731–736PubMedCrossRef Post WR, Akers SR, Kish V (1997) Load to failure of common meniscal repair techniques: effects of suture technique and suture material. Arthroscopy 13(6):731–736PubMedCrossRef
13.
go back to reference Proctor CS, Schmidt MB, Whipple RR, et al (1989) Material properties of the normal medial bovine meniscus. J Orthop Res 7(6):771–782PubMedCrossRef Proctor CS, Schmidt MB, Whipple RR, et al (1989) Material properties of the normal medial bovine meniscus. J Orthop Res 7(6):771–782PubMedCrossRef
14.
go back to reference Rankin CC, Lintner DM, Noble PC, et al (2002) A biomechanical analysis of meniscal repair techniques. Am J Sports Med 30(4):492–497PubMed Rankin CC, Lintner DM, Noble PC, et al (2002) A biomechanical analysis of meniscal repair techniques. Am J Sports Med 30(4):492–497PubMed
15.
go back to reference Rimmer MG, Nawana NS, Keene GC, Pearcy MJ (1995) Failure strengths of different meniscal suturing techniques. Arthroscopy 11(2):146–150PubMedCrossRef Rimmer MG, Nawana NS, Keene GC, Pearcy MJ (1995) Failure strengths of different meniscal suturing techniques. Arthroscopy 11(2):146–150PubMedCrossRef
16.
go back to reference Sgaglione NA, Steadman JR, Shaffer B, et al (2003) Current concepts in meniscus surgery: resection to replacement. Arthroscopy 19(Suppl 1):161–188PubMedCrossRef Sgaglione NA, Steadman JR, Shaffer B, et al (2003) Current concepts in meniscus surgery: resection to replacement. Arthroscopy 19(Suppl 1):161–188PubMedCrossRef
17.
go back to reference Song EK, Lee KB (1999) Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy 15(7):726–732PubMedCrossRef Song EK, Lee KB (1999) Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy 15(7):726–732PubMedCrossRef
18.
go back to reference Sweigart MA, Zhu CF, Burt DM, DeHoll PD, Agrawal CM, Clanton TO, Athanasiou KA (2004) Intraspecies and interspecies comparison of the compressive properties of the medial meniscus. Ann Biomed Eng 32(11):1569–1579PubMedCrossRef Sweigart MA, Zhu CF, Burt DM, DeHoll PD, Agrawal CM, Clanton TO, Athanasiou KA (2004) Intraspecies and interspecies comparison of the compressive properties of the medial meniscus. Ann Biomed Eng 32(11):1569–1579PubMedCrossRef
19.
go back to reference Voloshin AS, Wosk J (1983) Shock absorption of meniscectomized and painful knees: a comparative in vivo study. J Biomed Eng 5(2):157–161PubMed Voloshin AS, Wosk J (1983) Shock absorption of meniscectomized and painful knees: a comparative in vivo study. J Biomed Eng 5(2):157–161PubMed
Metadata
Title
Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques
Authors
Yavuz Kocabey
Omer Taser
John Nyland
Mahmut Nedim Doral
Mehmet Demirhan
David N. M. Caborn
Sezgin Sarban
Publication date
01-10-2006
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 10/2006
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-006-0079-9

Other articles of this Issue 10/2006

Knee Surgery, Sports Traumatology, Arthroscopy 10/2006 Go to the issue