Skip to main content
Top
Published in: European Spine Journal 7/2007

01-07-2007 | Original Article

Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies

Authors: Konrad Seller, Dieter Wahl, Alexander Wild, Rüdiger Krauspe, Erich Schneider, Berend Linke

Published in: European Spine Journal | Issue 7/2007

Login to get access

Abstract

A lot of new implant devices for spine surgery are coming onto the market, in which vertebral screws play a fundamental role. The new screws developed for surgery of spine deformities have to be compared to established systems. A biomechanical in vitro study was designed to assess the bone–screw interface fixation strength of seven different screws used for correction of scoliosis in spine surgery. The objectives of the current study were twofold: (1) to evaluate the initial strength at the bone–screw interface of newly developed vertebral screws (Universal Spine System II) compared to established systems (product comparison) and (2) to evaluate the influence of screw design, screw diameter, screw length and bone mineral density on pullout strength. Fifty-six calf vertebral bodies were instrumented with seven different screws (USS II anterior 8.0 mm, USS II posterior 6.2 mm, KASS 6.25 mm, USS II anterior 6.2 mm, USS II posterior 5.2 mm, USS 6.0 mm, USS 5.0 mm). Bone mineral density (BMD) was determined by quantitative computed tomography (QCT). Failure in axial pullout was tested using a displacement-controlled universal test machine. USS II anterior 8.0 mm showed higher pullout strength than all other screws. The difference constituted a tendency (P = 0.108) when compared to USS II posterior 6.2 mm (+19%) and was significant in comparison to the other screws (+30 to +55%, P < 0.002). USS II posterior 6.2 mm showed significantly higher pullout strength than USS 5.0 mm (+30%, P = 0.014). The other screws did not differ significantly in pullout strength. Pullout strength correlated significantly with BMD (P = 0.0015) and vertebral body width/screw length (P < 0.001). The newly developed screws for spine surgery (USS II) show higher pullout strength when compared to established systems. Screw design had no significant influence on pullout force in vertebral body screws, but outer diameter of the screw, screw length and BMD are good predictors of pullout resistance.
Literature
1.
go back to reference Alobaid A, Arlet V, Busato A et al (2005) Pull-out strength of the suprapedicle claw construct: a biomechanical study. Eur Spine J 14:759–764PubMedCrossRef Alobaid A, Arlet V, Busato A et al (2005) Pull-out strength of the suprapedicle claw construct: a biomechanical study. Eur Spine J 14:759–764PubMedCrossRef
2.
go back to reference Bai B, Kummer FJ, Spivak J (2001) Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine 26:2679–2683PubMedCrossRef Bai B, Kummer FJ, Spivak J (2001) Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine 26:2679–2683PubMedCrossRef
3.
go back to reference Breeze SW, Doherty BJ, Noble PS et al (1998) A biomechanical study of anterior thoracolumbar screw fixation. Spine 23:1829–1831PubMedCrossRef Breeze SW, Doherty BJ, Noble PS et al (1998) A biomechanical study of anterior thoracolumbar screw fixation. Spine 23:1829–1831PubMedCrossRef
4.
go back to reference Brantley AGU, Mayfield JK, Koenemann JB et al (1994) The effects of pedicle screw fit: an in vitro study. Spine 19:1752–1758PubMedCrossRef Brantley AGU, Mayfield JK, Koenemann JB et al (1994) The effects of pedicle screw fit: an in vitro study. Spine 19:1752–1758PubMedCrossRef
5.
go back to reference Cotterill PC, Kostuik JP, D`Angelo G et al (1986) An anatomical comparison of the human and bovine thorakolumbar spine. J Orthopaedic Res 4:298–303CrossRef Cotterill PC, Kostuik JP, D`Angelo G et al (1986) An anatomical comparison of the human and bovine thorakolumbar spine. J Orthopaedic Res 4:298–303CrossRef
6.
go back to reference Dwyer AF, Newton NC, Sherwood AA (1969) An anterior approach to scoliosis: a preliminary report. Clin Orthop 62:191–202 Dwyer AF, Newton NC, Sherwood AA (1969) An anterior approach to scoliosis: a preliminary report. Clin Orthop 62:191–202
7.
go back to reference Eysel P, Schwitalle M, Oberstein A et al (1998) Preoperative estimation of screw fixation strength in vertebral bodies. Spine 23:174–180PubMedCrossRef Eysel P, Schwitalle M, Oberstein A et al (1998) Preoperative estimation of screw fixation strength in vertebral bodies. Spine 23:174–180PubMedCrossRef
8.
go back to reference Farcy JP, Weidenbaum M, Michelsen CB et al (1987) A comparative biomechanical study of spinal fixation using Cotrel-Dubousset instrumentation. Spine 12:877–881PubMedCrossRef Farcy JP, Weidenbaum M, Michelsen CB et al (1987) A comparative biomechanical study of spinal fixation using Cotrel-Dubousset instrumentation. Spine 12:877–881PubMedCrossRef
9.
go back to reference Ferguson SJ, Winkler F, Nolte LP (2002) Anterior fixation in the osteoporotic spine: cut-out and pullout characteristics of implants. Eur Spine J 11:527–534PubMedCrossRef Ferguson SJ, Winkler F, Nolte LP (2002) Anterior fixation in the osteoporotic spine: cut-out and pullout characteristics of implants. Eur Spine J 11:527–534PubMedCrossRef
10.
go back to reference Frandsen PA, Christofferson H, Madsen T (1984) Holding Power of different screws in the femoral head. Acta Othop 55:349–351 Frandsen PA, Christofferson H, Madsen T (1984) Holding Power of different screws in the femoral head. Acta Othop 55:349–351
11.
go back to reference Gaines RW, Carson WL, Satterlee CC et al (1991) Experimental evaluation of seven different spinal fracture internal fixation devices using nonfailure stability testing. Spine 16:902–909PubMedCrossRef Gaines RW, Carson WL, Satterlee CC et al (1991) Experimental evaluation of seven different spinal fracture internal fixation devices using nonfailure stability testing. Spine 16:902–909PubMedCrossRef
12.
go back to reference Gilbert SG, Johns PC, Chow DC et al (1993) Relation of vertebral bone screw axial pullout strength to quantitative computed tomographic trabecular bone mineral content. J Spinal Disord 6:513–521PubMed Gilbert SG, Johns PC, Chow DC et al (1993) Relation of vertebral bone screw axial pullout strength to quantitative computed tomographic trabecular bone mineral content. J Spinal Disord 6:513–521PubMed
13.
go back to reference Gurr KR, McAfee PC, Shih CM (1988) Biomechanical analysis of posterior instrumentation systems after decompressive laminectomy: an unstable calf-spine model. J Bone Joint Surg Am 70:680–691PubMed Gurr KR, McAfee PC, Shih CM (1988) Biomechanical analysis of posterior instrumentation systems after decompressive laminectomy: an unstable calf-spine model. J Bone Joint Surg Am 70:680–691PubMed
14.
go back to reference Gurwitz GS, Dawson JM, McNamara MJ et al (1993) Biomechanical analysis of three surgical approaches for lumbar burst fractures using short-segment instrumentation. Spine 18:977–982PubMedCrossRef Gurwitz GS, Dawson JM, McNamara MJ et al (1993) Biomechanical analysis of three surgical approaches for lumbar burst fractures using short-segment instrumentation. Spine 18:977–982PubMedCrossRef
15.
go back to reference Hackenberg L, Clahsen H, Halm H (1998) Influencing factors on the holding-power of spine surgery screws—experimental examninations. Z Orthop Ihre Grenzgeb 136:451–456PubMed Hackenberg L, Clahsen H, Halm H (1998) Influencing factors on the holding-power of spine surgery screws—experimental examninations. Z Orthop Ihre Grenzgeb 136:451–456PubMed
16.
go back to reference Halvorson TL, Kelley LA, Thomas KA et al (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415–2420PubMedCrossRef Halvorson TL, Kelley LA, Thomas KA et al (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415–2420PubMedCrossRef
17.
go back to reference Hopf C, Eysel P, Dubousset J (1995) CDH—first report on a new primary stable anterior spine instrumentation. Z Orthop Ihre Grenzgeb 133:274–281PubMed Hopf C, Eysel P, Dubousset J (1995) CDH—first report on a new primary stable anterior spine instrumentation. Z Orthop Ihre Grenzgeb 133:274–281PubMed
18.
go back to reference Horton WC, Blackstock SF, Norman JT et al (1996) Strength of fixation of anterior vertebral body screws. Spine 21:439–444PubMedCrossRef Horton WC, Blackstock SF, Norman JT et al (1996) Strength of fixation of anterior vertebral body screws. Spine 21:439–444PubMedCrossRef
19.
go back to reference Hughes AN, Jordan BA (1972) The mechanical properties of surgical bone screws and some aspects of insertions practice. Injury 4:25–37PubMedCrossRef Hughes AN, Jordan BA (1972) The mechanical properties of surgical bone screws and some aspects of insertions practice. Injury 4:25–37PubMedCrossRef
20.
go back to reference Jordan BA, Hughes AN (1978) A review of the factors affecting design, specification and material selection of screws for use in orthopedic surgery. Eng Med 7:114–123 Jordan BA, Hughes AN (1978) A review of the factors affecting design, specification and material selection of screws for use in orthopedic surgery. Eng Med 7:114–123
21.
go back to reference Kaneda K, Shono Y, Satoh S et al (1996) New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis: application of the Kaneda two-rod system. Spine 21:1250–1262PubMedCrossRef Kaneda K, Shono Y, Satoh S et al (1996) New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis: application of the Kaneda two-rod system. Spine 21:1250–1262PubMedCrossRef
22.
go back to reference Korovessis PG, Deligianni D, Stamakis M et al (1998) Augmentation of anterior transvertebral screws using threaded teflon anchoring. J Spinal Disord 11:300–306PubMed Korovessis PG, Deligianni D, Stamakis M et al (1998) Augmentation of anterior transvertebral screws using threaded teflon anchoring. J Spinal Disord 11:300–306PubMed
23.
go back to reference Kumano K, Hirabayasi S, Ogawa Y et al (1994) Pedicle screws and bone mineral density. Spine 19:1157–1161PubMedCrossRef Kumano K, Hirabayasi S, Ogawa Y et al (1994) Pedicle screws and bone mineral density. Spine 19:1157–1161PubMedCrossRef
24.
go back to reference Liebermann IH, Khazim R. Woodside T (1998) Anterior vertebral body screw pullout testing. A comparison of Zielke, Kaneda, Universal Spine System, and Universal Spine System with pullout-resistant nut. Spine 23:908–910CrossRef Liebermann IH, Khazim R. Woodside T (1998) Anterior vertebral body screw pullout testing. A comparison of Zielke, Kaneda, Universal Spine System, and Universal Spine System with pullout-resistant nut. Spine 23:908–910CrossRef
25.
go back to reference Lim TH, An HS, Evanich C et al (1995) Strength of anterior vertebral screw fixation in relationship to bone mineral density. J Spinal Disord 8:121–125PubMedCrossRef Lim TH, An HS, Evanich C et al (1995) Strength of anterior vertebral screw fixation in relationship to bone mineral density. J Spinal Disord 8:121–125PubMedCrossRef
26.
go back to reference Lim TH, An HS, Hong JH et al (1997) Biomechanical Evaluation of anterior and posterior fixations in an unstable calf spine model. Spine 22:261–266PubMedCrossRef Lim TH, An HS, Hong JH et al (1997) Biomechanical Evaluation of anterior and posterior fixations in an unstable calf spine model. Spine 22:261–266PubMedCrossRef
27.
go back to reference Lin LC, Chen HH, Sun SP (2003) A biomechanical study of the cortex anchorage vertebral screw. Clin Biomech 18:25–32CrossRef Lin LC, Chen HH, Sun SP (2003) A biomechanical study of the cortex anchorage vertebral screw. Clin Biomech 18:25–32CrossRef
28.
go back to reference Mosekilde L, Mosekilde L, Danielsen CC (1987) Biomechanical competence of vertebral trabecular bone in relation to ash density and age in normal individuals. Bone 8:79–86PubMedCrossRef Mosekilde L, Mosekilde L, Danielsen CC (1987) Biomechanical competence of vertebral trabecular bone in relation to ash density and age in normal individuals. Bone 8:79–86PubMedCrossRef
29.
go back to reference Nunamaker DM, Perren SM (1976) Force measurement in screw fixation. J Biomech 9:669–675CrossRef Nunamaker DM, Perren SM (1976) Force measurement in screw fixation. J Biomech 9:669–675CrossRef
30.
go back to reference Ogon M, Haid C, Krismer M et al (1996) Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. Spine 21:2728–2734PubMedCrossRef Ogon M, Haid C, Krismer M et al (1996) Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. Spine 21:2728–2734PubMedCrossRef
31.
go back to reference Okuyama K, Sato K, Abe E et al (1993) Stability of transpedicle screwing for the osteoporotic spine. Spine 18:2240–2245PubMedCrossRef Okuyama K, Sato K, Abe E et al (1993) Stability of transpedicle screwing for the osteoporotic spine. Spine 18:2240–2245PubMedCrossRef
32.
go back to reference Pfeiffer M, Gilbertson LG, Goel VK et al (1996) Effect of specimen fixation method on pullout tests of pedicle screws. Spine 21:1037–1044PubMedCrossRef Pfeiffer M, Gilbertson LG, Goel VK et al (1996) Effect of specimen fixation method on pullout tests of pedicle screws. Spine 21:1037–1044PubMedCrossRef
33.
go back to reference Pitzen T, Barbier D, Tintinger F et al (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499PubMedCrossRef Pitzen T, Barbier D, Tintinger F et al (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494–499PubMedCrossRef
34.
go back to reference Pitzen T Franta F, Barbier D et al (2004) Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole. J Neurosurg Spine 1:198–201 Pitzen T Franta F, Barbier D et al (2004) Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole. J Neurosurg Spine 1:198–201
35.
go back to reference Pitzen T, Drumm J, Bruchmann B et al (2006) Effectiveness of cemented rescue screws for anterior cervical plate fixation. J Neurosurg Spine 4:60–63PubMed Pitzen T, Drumm J, Bruchmann B et al (2006) Effectiveness of cemented rescue screws for anterior cervical plate fixation. J Neurosurg Spine 4:60–63PubMed
36.
go back to reference Rassi-Neto A, Shimano A (2002) Biomechanical properties of expander compared with conventional screws. J Neurosurg Spine 3 97:346–349 Rassi-Neto A, Shimano A (2002) Biomechanical properties of expander compared with conventional screws. J Neurosurg Spine 3 97:346–349
37.
go back to reference Reinhold M, Schwieger K, Goldhahn J et al (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine 31:406–413PubMedCrossRef Reinhold M, Schwieger K, Goldhahn J et al (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine 31:406–413PubMedCrossRef
38.
go back to reference Riley LH, Eck JC, Yoshida H et al (2004) A biomechanical comparison of calf versus cadaver lumbar spine models. Spine 29:E217–E220PubMedCrossRef Riley LH, Eck JC, Yoshida H et al (2004) A biomechanical comparison of calf versus cadaver lumbar spine models. Spine 29:E217–E220PubMedCrossRef
39.
go back to reference Schatzker J, Sanderson R, Murnaghan JP (1975) The holding power of orthopedic screws in vivo. Clin Orthop 108:115–126PubMedCrossRef Schatzker J, Sanderson R, Murnaghan JP (1975) The holding power of orthopedic screws in vivo. Clin Orthop 108:115–126PubMedCrossRef
40.
go back to reference Schramm M, Rumbein S, Kraus H et al (2003) Anterior vertebral body screw pullout testing with the hollow modular anchorage system—a comparative in vitro study. Biomed Technik 48:356–361CrossRef Schramm M, Rumbein S, Kraus H et al (2003) Anterior vertebral body screw pullout testing with the hollow modular anchorage system—a comparative in vitro study. Biomed Technik 48:356–361CrossRef
41.
42.
go back to reference Schultheiss M, Wilke HJ, Claes L et al (2002) MACS-TL polyaxial screw XL. A new concept for increasing stability of ventral spondylodesis in the presence of dorsal injuries. Orthopäde 31:397–401PubMedCrossRef Schultheiss M, Wilke HJ, Claes L et al (2002) MACS-TL polyaxial screw XL. A new concept for increasing stability of ventral spondylodesis in the presence of dorsal injuries. Orthopäde 31:397–401PubMedCrossRef
43.
go back to reference Sell P, Collins M, Dove J (1988) Pedicle screws: axial pull-out strength in lumbar spine. Spine 13:1075–1076PubMedCrossRef Sell P, Collins M, Dove J (1988) Pedicle screws: axial pull-out strength in lumbar spine. Spine 13:1075–1076PubMedCrossRef
44.
go back to reference Shimamoto N, Kotani Y, Shono Y et al (2001) Biomechanical evaluation of anterior spinal instrumentation systems for scoliosis: in vitro fatigue simulation. Spine 26:2701–2708PubMedCrossRef Shimamoto N, Kotani Y, Shono Y et al (2001) Biomechanical evaluation of anterior spinal instrumentation systems for scoliosis: in vitro fatigue simulation. Spine 26:2701–2708PubMedCrossRef
45.
go back to reference Shono Y, Kaneda K, Yamamoto I (1991) A biomechanical analysis of Zielke, Kaneda, and Cotrel-Dubousset instrumentations in thoracolumbar scoliosis: a calf spine model. Spine 16:1305–1311PubMedCrossRef Shono Y, Kaneda K, Yamamoto I (1991) A biomechanical analysis of Zielke, Kaneda, and Cotrel-Dubousset instrumentations in thoracolumbar scoliosis: a calf spine model. Spine 16:1305–1311PubMedCrossRef
46.
go back to reference Skinner R, Maybee J, Transfeld E et al (1990) Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 15:195–201PubMedCrossRef Skinner R, Maybee J, Transfeld E et al (1990) Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 15:195–201PubMedCrossRef
47.
go back to reference Snyder BD, Zaltz I, Hall JE et al (1993) Predicting the integrity of vertebral bone screw fixation in anterior spinal instrumentation. Spine 18:423–426 Snyder BD, Zaltz I, Hall JE et al (1993) Predicting the integrity of vertebral bone screw fixation in anterior spinal instrumentation. Spine 18:423–426
48.
go back to reference Soshi S, Shiba R, Kondo H et al (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341PubMedCrossRef Soshi S, Shiba R, Kondo H et al (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341PubMedCrossRef
49.
go back to reference Swartz DE, Wittenberg RH, Shea M et al (1991) Physical and mechanical properties of calf lumbosacral trabecular bone. J Biomech 24:1059–1068PubMedCrossRef Swartz DE, Wittenberg RH, Shea M et al (1991) Physical and mechanical properties of calf lumbosacral trabecular bone. J Biomech 24:1059–1068PubMedCrossRef
50.
go back to reference Teschner W, Manitz V, Holzweißig E et al (1983) Anchoring experiments on human cadaver vertebrae using various types of screws. Z Orthop Ihre Grenzgeb 157:206–208CrossRef Teschner W, Manitz V, Holzweißig E et al (1983) Anchoring experiments on human cadaver vertebrae using various types of screws. Z Orthop Ihre Grenzgeb 157:206–208CrossRef
51.
go back to reference Turi M, Johnston CE II, Richards BS (1993) Anterior correction of idiopathic scoliosis using TSRH instrumentation. Spine 18:417–422PubMedCrossRef Turi M, Johnston CE II, Richards BS (1993) Anterior correction of idiopathic scoliosis using TSRH instrumentation. Spine 18:417–422PubMedCrossRef
52.
go back to reference Vangness CT, Carter RD, Frankel VH (1981) In vitro evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws. Clin Orthop 157:279–286 Vangness CT, Carter RD, Frankel VH (1981) In vitro evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws. Clin Orthop 157:279–286
53.
go back to reference Wilke HJ, Krischak ST Claes LE (1996) Biomechanical comparison of calf and human spines. J Orthop Res 14:500–503PubMedCrossRef Wilke HJ, Krischak ST Claes LE (1996) Biomechanical comparison of calf and human spines. J Orthop Res 14:500–503PubMedCrossRef
54.
go back to reference Wilke HK, Krischak ST, Wenger KH et al (1997) Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data. Eur Spine J 6:129–137PubMedCrossRef Wilke HK, Krischak ST, Wenger KH et al (1997) Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data. Eur Spine J 6:129–137PubMedCrossRef
55.
go back to reference Wittenberg RH, Shea M, Edwards WT et al (1992) A biomechanical study of the fatigue characteristics of thoracolumbar fixation implants in a calf spine model. Spine 17:121–128CrossRef Wittenberg RH, Shea M, Edwards WT et al (1992) A biomechanical study of the fatigue characteristics of thoracolumbar fixation implants in a calf spine model. Spine 17:121–128CrossRef
56.
go back to reference Yamagata M, Kithahara H, Minami S et al (1992) Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine 17(suppl):51–54CrossRef Yamagata M, Kithahara H, Minami S et al (1992) Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine 17(suppl):51–54CrossRef
57.
go back to reference Zdeblick TA, Warden KE, Zou D et al (1993) Anterior spinal fixators: a biomechanical in vitro study. Spine 18:513–517PubMed Zdeblick TA, Warden KE, Zou D et al (1993) Anterior spinal fixators: a biomechanical in vitro study. Spine 18:513–517PubMed
58.
go back to reference Zielke K, Stunkat R, Beaujean F (1976) Ventrale derotationsspondylodese. Arch Orthop Unfallchir 85:257–277PubMedCrossRef Zielke K, Stunkat R, Beaujean F (1976) Ventrale derotationsspondylodese. Arch Orthop Unfallchir 85:257–277PubMedCrossRef
Metadata
Title
Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies
Authors
Konrad Seller
Dieter Wahl
Alexander Wild
Rüdiger Krauspe
Erich Schneider
Berend Linke
Publication date
01-07-2007
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 7/2007
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-007-0307-0

Other articles of this Issue 7/2007

European Spine Journal 7/2007 Go to the issue