Abstract

Purpose

Laparoscopic mesh repair is an established alternative to the open repair of herniae of the antero-lateral abdominal wall. However, a definition in the literature of “recurrence” is lacking. This study reviews the phenomenon of pseudo-recurrence in patients who describe recurrent symptoms despite an apparently successful laparoscopic ventral or incisional hernia repair (LVIHR).

Methods

Cases of LVIHR from 1st January 2004 to 31st December 2007 were identified from the Lothian Surgical Audit database. Patients were contacted by telephone after a minimum of 11 months following operation. Pseudo-recurrences were identified by history and clinical examination, together with radiological investigation if the diagnosis remained in doubt.

Results

One hundred and forty-three repairs were performed in the study period. One hundred and twenty-one patients were contacted (63 incisional and 58 other ventral herniae). Twenty possible recurrences were reported (16.5%). Four were true recurrences and two more were new incisional herniae. There were 14 pseudo-recurrences, arising after 12 incisional and two other ventral hernia repairs. These were due to mesh bulge (10), seroma (3) and retained hernia contents (1).

Conclusion

True recurrences after LVIHR do occur but should be preventable with good surgical technique. Pseudo-recurrences are more common and may mimic true recurrence. We recommend computed tomography (CT) to clarify the diagnosis and determine the indication for revisional surgery.
Literature
1.
go back to reference Pham CT, Perera CL, Watkin DS, Maddern GJ (2009) Laparoscopic ventral hernia repair: a systematic review. Surg Endosc 23:4–15CrossRefPubMed Pham CT, Perera CL, Watkin DS, Maddern GJ (2009) Laparoscopic ventral hernia repair: a systematic review. Surg Endosc 23:4–15CrossRefPubMed
2.
go back to reference Bageacu S, Blanc P, Breton C, Gonzales M, Porcheron J, Chabert M, Balique JG (2002) Laparoscopic repair of incisional hernia: a retrospective study of 159 patients. Surg Endosc 16:345–348CrossRefPubMed Bageacu S, Blanc P, Breton C, Gonzales M, Porcheron J, Chabert M, Balique JG (2002) Laparoscopic repair of incisional hernia: a retrospective study of 159 patients. Surg Endosc 16:345–348CrossRefPubMed
3.
go back to reference Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 204:578–585 Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 204:578–585
4.
go back to reference LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed
5.
go back to reference Tsimoyiannis EC, Tassis A, Glantzounis G, Jabarin M, Siakas P, Tzourou H (1998) Laparoscopic intraperitoneal onlay mesh repair of incisional hernia. Surg Laparosc Endosc 8:360–362CrossRefPubMed Tsimoyiannis EC, Tassis A, Glantzounis G, Jabarin M, Siakas P, Tzourou H (1998) Laparoscopic intraperitoneal onlay mesh repair of incisional hernia. Surg Laparosc Endosc 8:360–362CrossRefPubMed
6.
go back to reference Rosenberg J, Burcharth J (2008) Feasibility and outcome after laparoscopic ventral hernia repair using Proceed mesh. Hernia 12:453–456CrossRefPubMed Rosenberg J, Burcharth J (2008) Feasibility and outcome after laparoscopic ventral hernia repair using Proceed mesh. Hernia 12:453–456CrossRefPubMed
7.
go back to reference Wassenaar EB, Schoenmaeckers EJ, Raymakers JT, Rakic S (2009) Recurrences after laparoscopic repair of ventral and incisional hernia: lessons learned from 505 repairs. Surg Endosc 23:825–832CrossRefPubMed Wassenaar EB, Schoenmaeckers EJ, Raymakers JT, Rakic S (2009) Recurrences after laparoscopic repair of ventral and incisional hernia: lessons learned from 505 repairs. Surg Endosc 23:825–832CrossRefPubMed
8.
go back to reference Cobb WS, Kercher KW, Matthews BD, Burns JM, Tinkham NH, Sing RF, Heniford BT (2006) Laparoscopic ventral hernia repair: a single center experience. Hernia 10:236–242CrossRefPubMed Cobb WS, Kercher KW, Matthews BD, Burns JM, Tinkham NH, Sing RF, Heniford BT (2006) Laparoscopic ventral hernia repair: a single center experience. Hernia 10:236–242CrossRefPubMed
9.
go back to reference Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–399PubMed Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–399PubMed
10.
go back to reference Schug-Pass C, Sommerer F, Tannapfel A, Lippert H, Köckerling F (2009) The use of composite meshes in laparoscopic repair of abdominal wall hernias: are there differences in biocompatibility?: experimental results obtained in a laparoscopic porcine model. Surg Endosc 23:487–495CrossRefPubMed Schug-Pass C, Sommerer F, Tannapfel A, Lippert H, Köckerling F (2009) The use of composite meshes in laparoscopic repair of abdominal wall hernias: are there differences in biocompatibility?: experimental results obtained in a laparoscopic porcine model. Surg Endosc 23:487–495CrossRefPubMed
11.
go back to reference Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed
12.
go back to reference Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214CrossRefPubMed Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214CrossRefPubMed
13.
go back to reference Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B, Parra-Davila E, Ramshaw B, Schumpelick V (2010) Hernia repair: the search for ideal meshes. Hernia 14:81–87CrossRefPubMed Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B, Parra-Davila E, Ramshaw B, Schumpelick V (2010) Hernia repair: the search for ideal meshes. Hernia 14:81–87CrossRefPubMed
14.
go back to reference LeBlanc KA, Booth WV, Whitaker JM, Bellanger DE (2000) Laparoscopic incisional and ventral herniorrhaphy in 100 patients. Am J Surg 180:193–197CrossRefPubMed LeBlanc KA, Booth WV, Whitaker JM, Bellanger DE (2000) Laparoscopic incisional and ventral herniorrhaphy in 100 patients. Am J Surg 180:193–197CrossRefPubMed
Metadata
Title
Pseudo-recurrence following laparoscopic ventral and incisional hernia repair
Authors
G. H. Tse
B. M. Stutchfield
A. D. Duckworth
A. C. de Beaux
B. Tulloh
Publication date
01-12-2010
Publisher
Springer-Verlag
Published in
Hernia / Issue 6/2010
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-010-0709-5

Other articles of this Issue 6/2010

Hernia 6/2010 Go to the issue