Skip to main content
Top
Published in: Surgical and Radiologic Anatomy 3/2020

01-03-2020 | Pseudarthrosis | Original Article

The sacral screw placement depending on morphological and anatomical peculiarities

Authors: Carolin Meyer, Peter Pfannebecker, Jan Siewe, David Grevenstein, Jan Bredow, Peer Eysel, Max Joseph Scheyerer

Published in: Surgical and Radiologic Anatomy | Issue 3/2020

Login to get access

Abstract

Purpose

Various pathologies of the lumbosacral junction require fusion of the L5/S1 segment. However, pseudarthroses, which often come along with sacral screw loosening, are problematic. The aim of the present investigation was to elaborate the morphological features of the L5/S1 segment to define a so-called “safe zone” for bi- or tricortical screw placement without risking a damage of the iliac vessels.

Methods

A total of one hundred computed tomographies of the pelvis were included in this investigation. On axial and sagittal slices, pedicle morphologies, the prevertebral position of the iliac vessels, the spinal canal and the area with the largest bone density were analyzed.

Results

Beginning from the entry point of S1-srews iliac vessels were located at an average angle of 7° convergence, the spinal canal at 38°. Bone density was significantly higher centrally with a mean value of 276 Hounsfield Units compared to the area of the Ala ossis sacri. The largest intraosseous screw length could be achieved at an angle of 25°. The average pedicle width was 20 mm and the pedicle height 13 mm.

Conclusions

A “safe-zone” for bicortical screw placement at S1 with regard to the course of the iliac vessels could be defined between 7° and 38° convergence. Regarding the area offering the largest bone density and the maximal possible screw length, a convergence of 25° is recommended at S1 to reduce the incidence of screw loosening. Screw diameter, as a further influence factor on screw holding, is limited by pedicle height not pedicle width.
Literature
1.
go back to reference Asher MA, Strippgen WE (1986) Anthropometric studies oft he human sacrum relating to dorsal transsacral implant designs. Clin Orthop 203:58 Asher MA, Strippgen WE (1986) Anthropometric studies oft he human sacrum relating to dorsal transsacral implant designs. Clin Orthop 203:58
2.
go back to reference Cho W, Cho SK, Wu C (2010) The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br 92-B:1061–1065CrossRef Cho W, Cho SK, Wu C (2010) The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg Br 92-B:1061–1065CrossRef
3.
go back to reference Cook S (2004) Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4:402–408CrossRef Cook S (2004) Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J 4:402–408CrossRef
4.
go back to reference Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS (2001) Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation ans osteoporosis. Spine J 1:109–114CrossRef Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS (2001) Lumbosacral fixation using expandable pedicle screws. An alternative in reoperation ans osteoporosis. Spine J 1:109–114CrossRef
5.
go back to reference De Peretti F, Argenson C, Bourgeon A, Omar F, Eude P, Aboulker C (1991) Anatomic and experimental basis fort he insertion of a screw at the first sacral vertebra. Surg Radiol Anat 13:133–137CrossRef De Peretti F, Argenson C, Bourgeon A, Omar F, Eude P, Aboulker C (1991) Anatomic and experimental basis fort he insertion of a screw at the first sacral vertebra. Surg Radiol Anat 13:133–137CrossRef
6.
go back to reference Gstöttner M, Glodny B, Petersen J, Thaler M, Bach CM (2011) CT Angiography for anterior lumbar spine access. High radiation exposure and low clinical relevance. Clin Orthop Relat Res 469:819–824CrossRef Gstöttner M, Glodny B, Petersen J, Thaler M, Bach CM (2011) CT Angiography for anterior lumbar spine access. High radiation exposure and low clinical relevance. Clin Orthop Relat Res 469:819–824CrossRef
7.
go back to reference Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T et al (1997) Structural characteristics of the pedicle and its role in screw stability. Spine 22:2504–2510CrossRef Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T et al (1997) Structural characteristics of the pedicle and its role in screw stability. Spine 22:2504–2510CrossRef
8.
go back to reference Kaptanoglu E, Okutan O, Tekdemir I, Beskonakli E, Deda H (2003) Closed posterior superior iliac spine impeding pediculocorporeal S1 screw insertion. J Neurosurg 99:229–234PubMed Kaptanoglu E, Okutan O, Tekdemir I, Beskonakli E, Deda H (2003) Closed posterior superior iliac spine impeding pediculocorporeal S1 screw insertion. J Neurosurg 99:229–234PubMed
9.
go back to reference Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry oft he thoracic and lumbar spine related to transpedicular screw placement for surgical spine fixation. Spine 13:27–32CrossRef Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry oft he thoracic and lumbar spine related to transpedicular screw placement for surgical spine fixation. Spine 13:27–32CrossRef
10.
go back to reference Lehman RA, Kuklo TR, Belmont PJ, Andersen RC, Polly DW (2002) Advantage of pedicle screw fixation directed into the apex the sacral promontory over bicortical fixation: a biomechanical analysis. Spine 15:806–811CrossRef Lehman RA, Kuklo TR, Belmont PJ, Andersen RC, Polly DW (2002) Advantage of pedicle screw fixation directed into the apex the sacral promontory over bicortical fixation: a biomechanical analysis. Spine 15:806–811CrossRef
11.
go back to reference Lei W, Wu Z (2006) Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J 15:321–326CrossRef Lei W, Wu Z (2006) Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J 15:321–326CrossRef
12.
go back to reference Lien SB, Lien SB, Liou NH, Wu SS (2007) Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J 16:1215–1222CrossRef Lien SB, Lien SB, Liou NH, Wu SS (2007) Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J 16:1215–1222CrossRef
13.
go back to reference McCord DH, Cunningham BW, Shono Y, Myers JJ, AcAfee PC (1992) Biomechanical analysis of lumbosacral fixation. Spine 17:235–243CrossRef McCord DH, Cunningham BW, Shono Y, Myers JJ, AcAfee PC (1992) Biomechanical analysis of lumbosacral fixation. Spine 17:235–243CrossRef
14.
go back to reference Pickhardt PJ, Poller BD, Lauder T, Munos del Rio A, Bruce RJ, Binkley N (2013) Opportunistic screening for osteoporosis using abdominal computed tomography scans obtained for other indications. Ann Int Med 158:588–595CrossRef Pickhardt PJ, Poller BD, Lauder T, Munos del Rio A, Bruce RJ, Binkley N (2013) Opportunistic screening for osteoporosis using abdominal computed tomography scans obtained for other indications. Ann Int Med 158:588–595CrossRef
15.
go back to reference Robertson PA, Stewart NR (2000) The radiologic anatomy oft he lumbar and lumbosacral pedicles. Spine 25:709–715CrossRef Robertson PA, Stewart NR (2000) The radiologic anatomy oft he lumbar and lumbosacral pedicles. Spine 25:709–715CrossRef
16.
go back to reference Sansur CA, Caffes NM, Ibrahimi DM, Pratt NL, Lewis EM, Murgatroyd AA, Cunningham BW (2016) Biomechanical fixation properties of cortical versus transpedicular screws in the osteoporotic lumbar spine: an in vitro human cadaveric model. Am Assoc Neurol Surg 25:1–10 Sansur CA, Caffes NM, Ibrahimi DM, Pratt NL, Lewis EM, Murgatroyd AA, Cunningham BW (2016) Biomechanical fixation properties of cortical versus transpedicular screws in the osteoporotic lumbar spine: an in vitro human cadaveric model. Am Assoc Neurol Surg 25:1–10
18.
go back to reference Voboril R (2001) Location oft he aortic bifurcation in man and its practical significance in vascular surgery. Zentralbl Chir 126:93–96CrossRef Voboril R (2001) Location oft he aortic bifurcation in man and its practical significance in vascular surgery. Zentralbl Chir 126:93–96CrossRef
19.
go back to reference Weiser L, Huber G, Sellenschloh K, Viezens L, Püschel K, Morlock MM, Lehmann W (2017) Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J 26:2891–2897CrossRef Weiser L, Huber G, Sellenschloh K, Viezens L, Püschel K, Morlock MM, Lehmann W (2017) Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J 26:2891–2897CrossRef
20.
go back to reference Wittenberg RH, Lee KS, Shea HM, White AA, Hayes WC (1993) Effect of screw diameter, insertion technique and bone cement augmentation of pedicular screw fixation stregth. Clin Orthop Relat Res 296:278–287 Wittenberg RH, Lee KS, Shea HM, White AA, Hayes WC (1993) Effect of screw diameter, insertion technique and bone cement augmentation of pedicular screw fixation stregth. Clin Orthop Relat Res 296:278–287
21.
go back to reference Xu R, Ebraheim NA, Gove NK (2008) Surgical anatomy of the sacrum. Am J Orthop 37:E177–E181PubMed Xu R, Ebraheim NA, Gove NK (2008) Surgical anatomy of the sacrum. Am J Orthop 37:E177–E181PubMed
22.
go back to reference Yoshii T, Hirai T, Yamada T, Sumiya S, Mastumoto R, Kato T et al (2015) Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and cannulated tapping device. J Orthop Surg Res 10:79–85CrossRef Yoshii T, Hirai T, Yamada T, Sumiya S, Mastumoto R, Kato T et al (2015) Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and cannulated tapping device. J Orthop Surg Res 10:79–85CrossRef
23.
go back to reference Zhu Q, Lu WW, Holmes AD, Zheng Y, Zhong S, Leong JC (2000) The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study. Spine 25:1065–1069CrossRef Zhu Q, Lu WW, Holmes AD, Zheng Y, Zhong S, Leong JC (2000) The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study. Spine 25:1065–1069CrossRef
24.
go back to reference Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field WT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99–112 Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field WT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99–112
Metadata
Title
The sacral screw placement depending on morphological and anatomical peculiarities
Authors
Carolin Meyer
Peter Pfannebecker
Jan Siewe
David Grevenstein
Jan Bredow
Peer Eysel
Max Joseph Scheyerer
Publication date
01-03-2020
Publisher
Springer Paris
Keyword
Pseudarthrosis
Published in
Surgical and Radiologic Anatomy / Issue 3/2020
Print ISSN: 0930-1038
Electronic ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-019-02373-x

Other articles of this Issue 3/2020

Surgical and Radiologic Anatomy 3/2020 Go to the issue