01-10-2008 | Hepatobiliary-Pancreas

Prospective comparison of high- and low-spatial-resolution dynamic MR imaging with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinoma

Authors: Masakatsu Tsurusaki, Richard C. Semelka, Kensuke Uotani, Koji Sugimoto, Masahiko Fujii, Kazuro Sugimura

Published in: European Radiology | Issue 10/2008

Login to get access

Abstract

The purpose of this study was to prospectively evaluate the efficacy of high-spatial-resolution dynamic MRI using sensitivity encoding (SENSE) in detection of hypervascular hepatocellular carcinoma (HCC). Thirty-five patients were included in this prospectively planned study, and 25 patients with 31 HCCs were assigned into three groups and underwent the following sequences: group A (n = 11): three-dimensional fast-gradient-echo (3D-FGE) high-spatial-resolution dynamic MRI (HR-MRI) with SENSE; group B (n = 10): 3D-FGE low-spatial-resolution dynamic MRI (LR-MRI) with SENSE; and group C (n = 14): 3D-FGE/LR-MRI without SENSE. For the quantitative analysis, the lesion-to-liver contrast-to-noise ratio (CNR) between the liver and HCCs was measured. For the qualitative analysis, overall image quality for each group was evaluated with a five-point scale analysis. The sensitivities for detection of HCCs were evaluated. The overall image quality in group A was significantly greater than both groups B and C (P < 0.01). The sensitivity of lesion detection on HAP was not significantly higher in group A (100%) than group C (69.2%; P > 0.05). In our pilot study on a small number of patients, image quality in HR-MRI with SENSE was superior to LR-MRI. A high detection rate was seen with HR-MRI with SENSE in the patients with hypervascular HCCs.
Literature
1.
go back to reference Yamashita Y, Mitsuzaki K, Yi T, Ogata I, Nishiharu T, Urata J, Takahashi M (1996) Small hepatocellular carcinoma in patients with chronic liver damage: prospective comparison of detection with dynamic MR imaging and helical CT of the whole liver. Radiology 200:79–84PubMed Yamashita Y, Mitsuzaki K, Yi T, Ogata I, Nishiharu T, Urata J, Takahashi M (1996) Small hepatocellular carcinoma in patients with chronic liver damage: prospective comparison of detection with dynamic MR imaging and helical CT of the whole liver. Radiology 200:79–84PubMed
2.
go back to reference Peterson MS, Baron RL, Murakami T (1996) Hepatic malignancies: usefulness of acquisition of multiple arterial and portal venous phase imaging at dynamic gadolinium-enhanced MR imaging. Radiology 201:337–345PubMed Peterson MS, Baron RL, Murakami T (1996) Hepatic malignancies: usefulness of acquisition of multiple arterial and portal venous phase imaging at dynamic gadolinium-enhanced MR imaging. Radiology 201:337–345PubMed
3.
go back to reference Yoshimitsu K, Honda H, Jimi M, Kuroiwa T, Irie H, Aibe H, Shinozaki K, Asayama Y, Shimada M, Masuda K (2001) Correlation of three-dimensional gradient echo dynamic MR imaging with CT during hepatic arteriography in patients with hypervascular hepatocellular carcinomas: preliminary clinical experience. J Magn Reson Imaging 13:258–262PubMedCrossRef Yoshimitsu K, Honda H, Jimi M, Kuroiwa T, Irie H, Aibe H, Shinozaki K, Asayama Y, Shimada M, Masuda K (2001) Correlation of three-dimensional gradient echo dynamic MR imaging with CT during hepatic arteriography in patients with hypervascular hepatocellular carcinomas: preliminary clinical experience. J Magn Reson Imaging 13:258–262PubMedCrossRef
4.
go back to reference Hecht EM, Holland AE, Israel GM, Hahn WY, Kim DC, West AB, Babb JS, Taouli B, Lee VS, Krinsky GA (2006) Hepatocellular carcinoma in the cirrhotic liver: gadolinium-enhanced 3D T1-weighted MR imaging as a stand-alone sequence for diagnosis. Radiology 239:438–447PubMedCrossRef Hecht EM, Holland AE, Israel GM, Hahn WY, Kim DC, West AB, Babb JS, Taouli B, Lee VS, Krinsky GA (2006) Hepatocellular carcinoma in the cirrhotic liver: gadolinium-enhanced 3D T1-weighted MR imaging as a stand-alone sequence for diagnosis. Radiology 239:438–447PubMedCrossRef
5.
go back to reference Kanematsu M, Hoshi H, Murakami T, Itoh K, Hori M, Kondo H, Nakamura H (1999) Detection of hepatocellular carcinoma: comparison of low- and high-spatial resolution dynamic MR images. AJR Am J Roentgenol 173:1207–1212PubMed Kanematsu M, Hoshi H, Murakami T, Itoh K, Hori M, Kondo H, Nakamura H (1999) Detection of hepatocellular carcinoma: comparison of low- and high-spatial resolution dynamic MR images. AJR Am J Roentgenol 173:1207–1212PubMed
6.
go back to reference Fujita T, Ito K, Honjo K, Okazaki H, Matsumoto T, Matsunaga N (1999) Detection of hepatocellular carcinoma: comparison of T2-weighted breath-hold fast spin-echo sequences and high-resolution dynamic MR imaging with a phased-array body coil. J Magn Reson Imaging 9:274–279PubMedCrossRef Fujita T, Ito K, Honjo K, Okazaki H, Matsumoto T, Matsunaga N (1999) Detection of hepatocellular carcinoma: comparison of T2-weighted breath-hold fast spin-echo sequences and high-resolution dynamic MR imaging with a phased-array body coil. J Magn Reson Imaging 9:274–279PubMedCrossRef
7.
go back to reference Ohtomo K, Matsuoka Y, Abe O, Okada M, Amo K, Minami M, Kawauchi N, Sasaki Y (1997) High-resolution MR imaging evaluation of hepatocellular carcinoma. Abdom Imaging 22:182–186PubMedCrossRef Ohtomo K, Matsuoka Y, Abe O, Okada M, Amo K, Minami M, Kawauchi N, Sasaki Y (1997) High-resolution MR imaging evaluation of hepatocellular carcinoma. Abdom Imaging 22:182–186PubMedCrossRef
8.
go back to reference Fujita T, Honjo K, Ito K, Matsumoto T, Matsunaga N, Hamm B (1997) High-resolution dynamic MR imaging of hepatocellular carcinoma with a phased-array body coil. Radiographics 17:315–31PubMed Fujita T, Honjo K, Ito K, Matsumoto T, Matsunaga N, Hamm B (1997) High-resolution dynamic MR imaging of hepatocellular carcinoma with a phased-array body coil. Radiographics 17:315–31PubMed
9.
go back to reference Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef
10.
go back to reference Golay X, Pruessmann KP, Weiger M, Crelier GR, Folkers PJ, Kollias SS, Boesiger P (2000) PRESTO-SENSE: an ultrafast whole-brain functional MRI technique. Magn Reson Med 43:779–786PubMedCrossRef Golay X, Pruessmann KP, Weiger M, Crelier GR, Folkers PJ, Kollias SS, Boesiger P (2000) PRESTO-SENSE: an ultrafast whole-brain functional MRI technique. Magn Reson Med 43:779–786PubMedCrossRef
11.
go back to reference Weiger M, Pruessmann KP, Boesiger P (2000) Cardiac real-time imaging using SENSE. Magn Reson Med 43:177–184PubMedCrossRef Weiger M, Pruessmann KP, Boesiger P (2000) Cardiac real-time imaging using SENSE. Magn Reson Med 43:177–184PubMedCrossRef
12.
go back to reference Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P (2000) Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 12:671–677PubMedCrossRef Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P (2000) Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 12:671–677PubMedCrossRef
13.
go back to reference Bammer R, Keeling SL, Augustin M, Pruessmann KP, Wolf R, Stollberger R, Hartung HP, Fazekas F (2001) Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 46:548–554PubMedCrossRef Bammer R, Keeling SL, Augustin M, Pruessmann KP, Wolf R, Stollberger R, Hartung HP, Fazekas F (2001) Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 46:548–554PubMedCrossRef
14.
go back to reference Ohno Y, Kawamitsu H, Higashino T, Takenaka D, Watanabe H, van Cauteren M, Fujii M, Hatabu H, Sugimura K (2003) Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE). J Magn Reson Imaging 17:330–336PubMedCrossRef Ohno Y, Kawamitsu H, Higashino T, Takenaka D, Watanabe H, van Cauteren M, Fujii M, Hatabu H, Sugimura K (2003) Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE). J Magn Reson Imaging 17:330–336PubMedCrossRef
15.
go back to reference Yoshioka H, Takahashi N, Yamaguchi M, Lou D, Saida Y, Itai Y (2002) Double arterial phase dynamic MRI with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinomas. J Magn Reson Imaging 16:259–266PubMedCrossRef Yoshioka H, Takahashi N, Yamaguchi M, Lou D, Saida Y, Itai Y (2002) Double arterial phase dynamic MRI with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinomas. J Magn Reson Imaging 16:259–266PubMedCrossRef
16.
go back to reference Takahashi N, Yoshioka H, Yamaguchi M, Saida Y, Itai Y (2003) Accelerated dynamic MR imaging with a parallel imaging technique for hypervascular hepatocellular carcinomas: usefulness of a test bolus in examination and subtraction imaging. J Magn Reson Imaging 18:80–89PubMedCrossRef Takahashi N, Yoshioka H, Yamaguchi M, Saida Y, Itai Y (2003) Accelerated dynamic MR imaging with a parallel imaging technique for hypervascular hepatocellular carcinomas: usefulness of a test bolus in examination and subtraction imaging. J Magn Reson Imaging 18:80–89PubMedCrossRef
17.
go back to reference Mori K, Yoshioka H, Takahashi N, Yamaguchi M, Ueno T, Yamaki T, Saida Y (2005) Triple arterial phase dynamic MRI with sensitivity encoding for hypervascular hepatocellular carcinoma: comparison of the diagnostic accuracy among the early, middle, late, and whole triple arterial phase imaging. AJR Am J Roentgenol 184:63–9PubMed Mori K, Yoshioka H, Takahashi N, Yamaguchi M, Ueno T, Yamaki T, Saida Y (2005) Triple arterial phase dynamic MRI with sensitivity encoding for hypervascular hepatocellular carcinoma: comparison of the diagnostic accuracy among the early, middle, late, and whole triple arterial phase imaging. AJR Am J Roentgenol 184:63–9PubMed
18.
go back to reference Kim YK, Kim CS, Kwak HS, Lee JM (2004) Three-dimensional dynamic liver MR imaging using sensitivity encoding for detection of hepatocellular carcinomas: comparison with superparamagnetic iron oxide-enhanced MR imaging. J Magn Reson Imaging 20:826–37PubMedCrossRef Kim YK, Kim CS, Kwak HS, Lee JM (2004) Three-dimensional dynamic liver MR imaging using sensitivity encoding for detection of hepatocellular carcinomas: comparison with superparamagnetic iron oxide-enhanced MR imaging. J Magn Reson Imaging 20:826–37PubMedCrossRef
19.
go back to reference Zech CJ, Herrmann KA, Huber A, Dietrich O, Stemmer A, Herzog P, Reiser MF, Schoenberg SO (2004) High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering. J Magn Reson Imaging 20:443–50PubMedCrossRef Zech CJ, Herrmann KA, Huber A, Dietrich O, Stemmer A, Herzog P, Reiser MF, Schoenberg SO (2004) High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering. J Magn Reson Imaging 20:443–50PubMedCrossRef
20.
go back to reference Tanaka O, Ito H, Yamada K, Kubota T, Kizu O, Kato T, Yamagami T, Nishimura T (2005) Higher lesion conspicuity for SENSE dynamic MRI in detecting hypervascular hepatocellular carcinoma: analysis through the measurements of liver SNR and lesion-liver CNR comparison with conventional dynamic MRI. Eur Radiol 15:2427–34PubMedCrossRef Tanaka O, Ito H, Yamada K, Kubota T, Kizu O, Kato T, Yamagami T, Nishimura T (2005) Higher lesion conspicuity for SENSE dynamic MRI in detecting hypervascular hepatocellular carcinoma: analysis through the measurements of liver SNR and lesion-liver CNR comparison with conventional dynamic MRI. Eur Radiol 15:2427–34PubMedCrossRef
21.
go back to reference Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM, Weinreb JC (1999) Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 212:876–884PubMed Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM, Weinreb JC (1999) Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 212:876–884PubMed
22.
go back to reference Kadoya M, Matsui O, Takashima T, Nonomura A (1992) Hepatocellular carcinoma: correlation of MR imaging and histopathologic findings. Radiology 183:819–825PubMed Kadoya M, Matsui O, Takashima T, Nonomura A (1992) Hepatocellular carcinoma: correlation of MR imaging and histopathologic findings. Radiology 183:819–825PubMed
Metadata
Title
Prospective comparison of high- and low-spatial-resolution dynamic MR imaging with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinoma
Authors
Masakatsu Tsurusaki
Richard C. Semelka
Kensuke Uotani
Koji Sugimoto
Masahiko Fujii
Kazuro Sugimura
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 10/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1003-0

Other articles of this Issue 10/2008

European Radiology 10/2008 Go to the issue