Skip to main content
Top
Published in: Neuroradiology 8/2004

01-08-2004 | Diagnostic Neuroradiology

Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization

Authors: H. Henkes, T. F. Gotwald, S. Brew, F. Kaemmerer, E. Miloslavski, D. Kuehne

Published in: Neuroradiology | Issue 8/2004

Login to get access

Abstract

Arteriovenous malformations (AVMs) are composed of abnormal arterial and venous vessels in the brain causing arteriovenous shunts of arterialized blood directly from pial arteries to draining veins. The hemodynamics of these lesions is not well-understood. Changes in blood flow and pressure are probably related to the natural history of AVMs and may also play a major role in AVM treatment. In this study intra-arterial pressure was measured in feeding arteries of AVMs using a microcatheter that had been placed for subsequent embolization treatment (201 measurements were performed in 95 patients before and after the embolization procedure). Results show a direct relationship between pressure changes and degree of embolization. Since pressure changes during the embolization procedure are relatively small, it seems unlikely that these changes are the direct cause of rupture and periprocedural bleedings.
Literature
1.
go back to reference Henkes H (2000) Endovaskuläre Behandlung zerebraler arteriovenöser Malformationen. Konzepte und Ergebnisse. Ecomed, Landsberg, pp 1–275 Henkes H (2000) Endovaskuläre Behandlung zerebraler arteriovenöser Malformationen. Konzepte und Ergebnisse. Ecomed, Landsberg, pp 1–275
2.
go back to reference Henkes H, Felber SR, Wentz KU, Czerwinski F, Monstadt H, Weber W, Kühne D (1999) Accuracy of intravascular microcatheter pressure measurements: an experimental study. Br. J Radiol 72:448–451 Henkes H, Felber SR, Wentz KU, Czerwinski F, Monstadt H, Weber W, Kühne D (1999) Accuracy of intravascular microcatheter pressure measurements: an experimental study. Br. J Radiol 72:448–451
3.
go back to reference Shapiro GG, Krovetz LJ (1970) Damped and undamped frequency responses of underdamped catheter manometer systems. Am Heart J 80:226–236CrossRefPubMed Shapiro GG, Krovetz LJ (1970) Damped and undamped frequency responses of underdamped catheter manometer systems. Am Heart J 80:226–236CrossRefPubMed
4.
go back to reference Jungreis CA, Horto, JA (1989) Pressure changes in the arterial feeder to a cerebral AVM as a guide to monitoring therapeutic embolization. AJNR Am J Neuroradiol 10:1057–1060PubMed Jungreis CA, Horto, JA (1989) Pressure changes in the arterial feeder to a cerebral AVM as a guide to monitoring therapeutic embolization. AJNR Am J Neuroradiol 10:1057–1060PubMed
5.
go back to reference Leblanc R, Little JR (1988) Hemodynamics of arteriovenous malformations. Clinical Neurosurgery 36:299–317 Leblanc R, Little JR (1988) Hemodynamics of arteriovenous malformations. Clinical Neurosurgery 36:299–317
6.
go back to reference Chimowitz MI, Little JR, Awa, IA, Sila CA, Kosmorsky G, Furla AJ (1990) Intracranial hypertension associated with unruptured cerebral arteriovenous malformations. Ann Neurol 27:474–479PubMed Chimowitz MI, Little JR, Awa, IA, Sila CA, Kosmorsky G, Furla AJ (1990) Intracranial hypertension associated with unruptured cerebral arteriovenous malformations. Ann Neurol 27:474–479PubMed
7.
go back to reference Barnett GH, Little JR, Ebrahi, ZY, Jones SC, Friel HT (1987) Cerebral circulation during arteriovenous malformation operation. Neurosurgery 20:836–842PubMed Barnett GH, Little JR, Ebrahi, ZY, Jones SC, Friel HT (1987) Cerebral circulation during arteriovenous malformation operation. Neurosurgery 20:836–842PubMed
8.
go back to reference Hassler W, Steinmetz H (1987) Cerebral hemodynamics in angioma patients: an intraoperative study. J Neurosurg 67:822–831PubMed Hassler W, Steinmetz H (1987) Cerebral hemodynamics in angioma patients: an intraoperative study. J Neurosurg 67:822–831PubMed
9.
go back to reference Jungreis CA, Horton JA, Hecht ST (1989) Blood pressure changes in feeders to cerebral arteriovenous malformations during therapeutic embolisation. AJNR Am J Neuroradiol 10:575–577PubMed Jungreis CA, Horton JA, Hecht ST (1989) Blood pressure changes in feeders to cerebral arteriovenous malformations during therapeutic embolisation. AJNR Am J Neuroradiol 10:575–577PubMed
10.
go back to reference Standard SC, Guterman LR, Chavis TD, Hopkins LN (1995) Delayed recanalization of a cerebral arteriovenous malformation following angiographic obliteration with polyvinyl alcohol embolization. Surg Neurol 44:109–113CrossRefPubMed Standard SC, Guterman LR, Chavis TD, Hopkins LN (1995) Delayed recanalization of a cerebral arteriovenous malformation following angiographic obliteration with polyvinyl alcohol embolization. Surg Neurol 44:109–113CrossRefPubMed
11.
go back to reference Ahuja A, Gibbons KJ, Guterman LR, Hopkins LN (1993) Pedicle pressure changes in cerebral arteriovenous malformations during therapeutic embolization: Relationship to delayed hemorrhage. Stroke 24:185 Ahuja A, Gibbons KJ, Guterman LR, Hopkins LN (1993) Pedicle pressure changes in cerebral arteriovenous malformations during therapeutic embolization: Relationship to delayed hemorrhage. Stroke 24:185
12.
go back to reference Sorimachi T, Takeuchi S, Koike T, Minakawa T, Abe H, Tanaka R (1995) Blood pressure monitoring in feeding arteries of cerebral arteriovenous malformations during embolization: a preventive role in hemodynamic complications. Neurosurgery 37:1041–1047PubMed Sorimachi T, Takeuchi S, Koike T, Minakawa T, Abe H, Tanaka R (1995) Blood pressure monitoring in feeding arteries of cerebral arteriovenous malformations during embolization: a preventive role in hemodynamic complications. Neurosurgery 37:1041–1047PubMed
13.
go back to reference Handa T, Negoro M, Miyachi S, Sugita K (1993) Evaluation of pressure changes in feeding arteries during embolization of intracerebral arteriovenous malformations. J Neurosurg 79:383–389PubMed Handa T, Negoro M, Miyachi S, Sugita K (1993) Evaluation of pressure changes in feeding arteries during embolization of intracerebral arteriovenous malformations. J Neurosurg 79:383–389PubMed
14.
go back to reference Katayama Y, Tsubokawa T, Hirayama T, Himi K (1994) Continuous monitoring of jugular bulb oxygen saturation as a measure of the shunt flow of cerebral arteriovenous malformations. J Neurosurg 80:826–833PubMed Katayama Y, Tsubokawa T, Hirayama T, Himi K (1994) Continuous monitoring of jugular bulb oxygen saturation as a measure of the shunt flow of cerebral arteriovenous malformations. J Neurosurg 80:826–833PubMed
15.
go back to reference Murayama Y, Massoud TF, Viñuela F (1998) Hemodynamic changes in arterial feeders and draining veins during embolotherapy of arteriovenous malformations: an experimental study in a swine model. Neurosurgery 43:96–104PubMed Murayama Y, Massoud TF, Viñuela F (1998) Hemodynamic changes in arterial feeders and draining veins during embolotherapy of arteriovenous malformations: an experimental study in a swine model. Neurosurgery 43:96–104PubMed
Metadata
Title
Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization
Authors
H. Henkes
T. F. Gotwald
S. Brew
F. Kaemmerer
E. Miloslavski
D. Kuehne
Publication date
01-08-2004
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 8/2004
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-004-1229-8

Other articles of this Issue 8/2004

Neuroradiology 8/2004 Go to the issue