Skip to main content
Top
Published in: Critical Care 1/2015

Open Access 01-12-2015 | Research

Preoperative intra-aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta-analysis of randomized controlled trials

Authors: Alberto Zangrillo, Federico Pappalardo, Roberto Dossi, Ambra Licia Di Prima, Marta Eugenia Sassone, Teresa Greco, Fabrizio Monaco, Mario Musu, Gabriele Finco, Giovanni Landoni

Published in: Critical Care | Issue 1/2015

Login to get access

Abstract

Introduction

The intra-aortic balloon pump is routinely used in cardiac surgery; however, its impact on outcome is still a matter of debate and several randomized trials have been published recently. We perform an updated meta-analysis of randomized controlled trials that investigated the use of preoperative intra-aortic balloon pump in adult patients undergoing coronary artery bypass grafting.

Methods

Potentially eligible trials were identified by searching the Medline, Embase, Scopus, ISI Web of Knowledge and The Cochrane Library. Searches were not restricted by language or publication status and were updated in August 2014. Randomized controlled trials on preoperative intra-aortic balloon pump in patients undergoing coronary artery bypass grafting either with or without cardiopulmonary bypass were identified. The primary end point was mortality at the longest follow-up available and the secondary end point was 30-day mortality.

Results

The eight included randomized clinical trials enrolled 625 patients (312 to the intra-aortic balloon pump group and 313 to control). The use of intra-aortic balloon pump was associated with a significant reduction in the risk of mortality (11 of 312 (3.5%) versus 33 of 313 (11%), risk ratio = 0.38 (0.20 to 0.73), P for effect = 0.004, P for heterogeneity = 0.7, I-square = 0%, with eight studies included). The benefit on mortality reduction was confirmed restricting the analysis to trials with low risk of bias, to those reporting 30-day follow-up and to patients undergoing coronary artery bypass graft surgery with cardiopulmonary bypass.

Conclusions

Preoperative intra-aortic balloon pump reduces perioperative and 30-day mortality in high-risk patients undergoing elective coronary artery bypass grafting.
Appendix
Available only for authorised users
Literature
1.
go back to reference Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic Balloon Pump in cardiogenic shock II (IABP-SHOCK II) trial investigators. Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial. Lancet. 2013;382:1638–45.CrossRef Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic Balloon Pump in cardiogenic shock II (IABP-SHOCK II) trial investigators. Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial. Lancet. 2013;382:1638–45.CrossRef
2.
go back to reference Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med. 2012;367:1287–96.CrossRef Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med. 2012;367:1287–96.CrossRef
3.
go back to reference Bolooki H. Clinical of intra-aortic balloon pump. New York: Futura Publishing Company; 1984. Bolooki H. Clinical of intra-aortic balloon pump. New York: Futura Publishing Company; 1984.
4.
go back to reference Weber KT, Janicki JS. Intra-aortic balloon counterpulsation – a review of physiological principles, clinical results, and device safety. Ann Thorac Surg. 1974;17:602–36.CrossRef Weber KT, Janicki JS. Intra-aortic balloon counterpulsation – a review of physiological principles, clinical results, and device safety. Ann Thorac Surg. 1974;17:602–36.CrossRef
5.
go back to reference Gill C, Wechsler A, Newman G, Oldham H. Augmentation and redistribution of myocardial blood flow during acute ischemia by intra-aortic balloon pumping. Ann ThoracSurg. 1975;16:445–53.CrossRef Gill C, Wechsler A, Newman G, Oldham H. Augmentation and redistribution of myocardial blood flow during acute ischemia by intra-aortic balloon pumping. Ann ThoracSurg. 1975;16:445–53.CrossRef
6.
go back to reference Watson JT, Willerson JT, DE Fixler DE, Sugg NL. Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping. Circulation. 1974;50:249–54. Watson JT, Willerson JT, DE Fixler DE, Sugg NL. Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping. Circulation. 1974;50:249–54.
7.
go back to reference Theologou T, Bashir M, Rengarajan A, Khan O, Spyt T, Richens D, et al. Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting. Cochrane Database Syst Rev. 2011; Art. No.: CD004472. Theologou T, Bashir M, Rengarajan A, Khan O, Spyt T, Richens D, et al. Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting. Cochrane Database Syst Rev. 2011; Art. No.: CD004472.
8.
go back to reference Dyub AM, Whitlock RP, Abouzahr LL, Cinà CS. Preoperative intra-aortic balloon pump in patients undergoing coronary bypass surgery: a systematic review and meta-analysis. J Card Surg. 2008;23:79–86.CrossRef Dyub AM, Whitlock RP, Abouzahr LL, Cinà CS. Preoperative intra-aortic balloon pump in patients undergoing coronary bypass surgery: a systematic review and meta-analysis. J Card Surg. 2008;23:79–86.CrossRef
9.
go back to reference Landoni G, Rodseth RN, Santini F, Ponschab M, Ruggeri L, Székely A, et al. Randomized evidence for reduction of perioperative mortality. J Cardiothorac Vasc Anesth. 2012;26:764–72.CrossRef Landoni G, Rodseth RN, Santini F, Ponschab M, Ruggeri L, Székely A, et al. Randomized evidence for reduction of perioperative mortality. J Cardiothorac Vasc Anesth. 2012;26:764–72.CrossRef
10.
go back to reference Ranucci M, Castelvecchio S, Biondi A, de Vincentiis C, Ballotta A, Varrica A, et al. A randomized controlled trial of preoperative intra-aortic balloon pump in coronary patients with poor left ventricular function undergoing coronary artery bypass surgery. Crit Care Med. 2013;41:2476–83.CrossRef Ranucci M, Castelvecchio S, Biondi A, de Vincentiis C, Ballotta A, Varrica A, et al. A randomized controlled trial of preoperative intra-aortic balloon pump in coronary patients with poor left ventricular function undergoing coronary artery bypass surgery. Crit Care Med. 2013;41:2476–83.CrossRef
12.
go back to reference Christenson JT, Badel P, Simonet F, Schmuziger M. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG. Ann Thorac Surg. 1997;64:1237–44.CrossRef Christenson JT, Badel P, Simonet F, Schmuziger M. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG. Ann Thorac Surg. 1997;64:1237–44.CrossRef
13.
go back to reference Christenson JT, Simonet F, Badel P, Schmuziger M. Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients. Eur J Cardiothorac Surg. 1997;11:1097–103.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients. Eur J Cardiothorac Surg. 1997;11:1097–103.CrossRef
14.
go back to reference Christenson JT, Simonet F, Badel P, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF < 40%), and hypertensive LV hypertrophy. Thorac Cardiovasc Surg. 1997;45:60–4.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF < 40%), and hypertensive LV hypertrophy. Thorac Cardiovasc Surg. 1997;45:60–4.CrossRef
15.
go back to reference Christenson JT, Simonet F, Badel P, Schmuziger M. Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients. Ann Thorac Surg. 1999;68:934–9.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients. Ann Thorac Surg. 1999;68:934–9.CrossRef
16.
go back to reference Christenson JT, Licker M, Kalangos A. The role of intra-aortic counterpulsation in high-risk OPCAB surgery: a prospective randomized study. J Card Surg. 2003;18:286–94.CrossRef Christenson JT, Licker M, Kalangos A. The role of intra-aortic counterpulsation in high-risk OPCAB surgery: a prospective randomized study. J Card Surg. 2003;18:286–94.CrossRef
17.
go back to reference Lomivorotov VV, Boboshko VA, Efremov SM, Kornilov IA, Chernyavskiy AM, Lomivorotov VN, et al. Levosimendan versus an intra-aortic balloon pump in high-risk cardiac patients. J Cardiothorac Vasc Anesth. 2012;26:596–603.CrossRef Lomivorotov VV, Boboshko VA, Efremov SM, Kornilov IA, Chernyavskiy AM, Lomivorotov VN, et al. Levosimendan versus an intra-aortic balloon pump in high-risk cardiac patients. J Cardiothorac Vasc Anesth. 2012;26:596–603.CrossRef
18.
go back to reference Shi M, Huang J, Pang L, Wang Y. Preoperative insertion of an intra-aortic balloon pump improved the prognosis of high-risk patients undergoing off-pump coronary artery bypass grafting. J Int Med Res. 2011;39:1163–8.CrossRef Shi M, Huang J, Pang L, Wang Y. Preoperative insertion of an intra-aortic balloon pump improved the prognosis of high-risk patients undergoing off-pump coronary artery bypass grafting. J Int Med Res. 2011;39:1163–8.CrossRef
19.
go back to reference Böning A, Buschbeck S, Roth P, Scheibelhut C, Bödeker RH, Brück M, et al. IABP before cardiac surgery: clinical benefit compared to intraoperative implantation. Perfusion. 2013;28:103–8.CrossRef Böning A, Buschbeck S, Roth P, Scheibelhut C, Bödeker RH, Brück M, et al. IABP before cardiac surgery: clinical benefit compared to intraoperative implantation. Perfusion. 2013;28:103–8.CrossRef
20.
go back to reference Hashemzadeh K, Hashemzadeh S. Early outcomes of intra-aortic balloon pump in cardiac surgery. J Cardiovasc Surg (Torino). 2012;53:387–92. Hashemzadeh K, Hashemzadeh S. Early outcomes of intra-aortic balloon pump in cardiac surgery. J Cardiovasc Surg (Torino). 2012;53:387–92.
21.
go back to reference Lomivorotov VV, Cherniavskiy AM, Boboshko VA, Kornilov IA, Lomivorotov VN, Karaskov AM. Levosimendan vs. intra-aortic balloon pump in high-risk cardiac surgery. Asian Cardiovasc Thorac Ann. 2011;19:154–9.CrossRef Lomivorotov VV, Cherniavskiy AM, Boboshko VA, Kornilov IA, Lomivorotov VN, Karaskov AM. Levosimendan vs. intra-aortic balloon pump in high-risk cardiac surgery. Asian Cardiovasc Thorac Ann. 2011;19:154–9.CrossRef
22.
go back to reference Madershahian N, Wippermann J, Liakopoulos O, Wittwer T, Kuhn E, Er F, et al. The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critical ill patients during ECMO. J Cardiovasc Surg (Torino). 2011;52:411–8. Madershahian N, Wippermann J, Liakopoulos O, Wittwer T, Kuhn E, Er F, et al. The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critical ill patients during ECMO. J Cardiovasc Surg (Torino). 2011;52:411–8.
23.
go back to reference Oberhoffer M, Weis M, Eifert S, Rassoulian D, Meiser B, Schmoeckel M, et al. Prospective randomized study of preoperative intraaortic balloon counterpulsation in high risk coronary artery bypass grafting patients, 542. Ottawa, Canada: 16th World Congress of the World Society of Cardio-Thoracic Surgeons; 2006. p. 191–2. Oberhoffer M, Weis M, Eifert S, Rassoulian D, Meiser B, Schmoeckel M, et al. Prospective randomized study of preoperative intraaortic balloon counterpulsation in high risk coronary artery bypass grafting patients, 542. Ottawa, Canada: 16th World Congress of the World Society of Cardio-Thoracic Surgeons; 2006. p. 191–2.
24.
go back to reference Serraino GF, Marsico R, Musolino G, Ventura V, Gulletta E, Santè P, et al. Pulsatile cardiopulmonary bypass with intra-aortic balloon pump improves organ function and reduces endothelial activation. Circ J. 2012;76:1121–9.CrossRef Serraino GF, Marsico R, Musolino G, Ventura V, Gulletta E, Santè P, et al. Pulsatile cardiopulmonary bypass with intra-aortic balloon pump improves organ function and reduces endothelial activation. Circ J. 2012;76:1121–9.CrossRef
25.
go back to reference Sá MP, Ferraz PE, Escobar RR, Martins WN, Nunes EO, Vasconcelos FP, et al. Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials. Coron Artery Dis. 2012;23:480–6.CrossRef Sá MP, Ferraz PE, Escobar RR, Martins WN, Nunes EO, Vasconcelos FP, et al. Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials. Coron Artery Dis. 2012;23:480–6.CrossRef
26.
go back to reference Bignami E, Tritapepe L, Pasin L, Meroni R, Corno L, Testa V, et al. A survey on the use of intra-aortic balloon pump in cardiac surgery. Ann Card Anaesth. 2012;15:274–7.CrossRef Bignami E, Tritapepe L, Pasin L, Meroni R, Corno L, Testa V, et al. A survey on the use of intra-aortic balloon pump in cardiac surgery. Ann Card Anaesth. 2012;15:274–7.CrossRef
27.
go back to reference Severi L, Vaccaro P, Covotta M, Landoni G, Lembo R, Menichetti A. Severe intra-aortic balloon pump complications: a single-center 12-year experience. J Cardiothorac Vasc Anesth. 2012;26:604–7.CrossRef Severi L, Vaccaro P, Covotta M, Landoni G, Lembo R, Menichetti A. Severe intra-aortic balloon pump complications: a single-center 12-year experience. J Cardiothorac Vasc Anesth. 2012;26:604–7.CrossRef
28.
go back to reference Greco T, Zangrillo A, Biondi-Zoccai G, Landoni G. Meta-analysis: pitfalls and hints. Heart Lung Vessel. 2013;5:219–25.PubMedPubMedCentral Greco T, Zangrillo A, Biondi-Zoccai G, Landoni G. Meta-analysis: pitfalls and hints. Heart Lung Vessel. 2013;5:219–25.PubMedPubMedCentral
29.
go back to reference Biondi-Zoccai G, Lotrionte M, Landoni G, Modena MG. The rough guide to systematic reviews and meta-analyses. HSR Proc Intensive Care Cardiovasc Anesth. 2011;3:161–73.PubMedPubMedCentral Biondi-Zoccai G, Lotrionte M, Landoni G, Modena MG. The rough guide to systematic reviews and meta-analyses. HSR Proc Intensive Care Cardiovasc Anesth. 2011;3:161–73.PubMedPubMedCentral
Metadata
Title
Preoperative intra-aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta-analysis of randomized controlled trials
Authors
Alberto Zangrillo
Federico Pappalardo
Roberto Dossi
Ambra Licia Di Prima
Marta Eugenia Sassone
Teresa Greco
Fabrizio Monaco
Mario Musu
Gabriele Finco
Giovanni Landoni
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2015
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-014-0728-1

Other articles of this Issue 1/2015

Critical Care 1/2015 Go to the issue