Skip to main content
Top
Published in: Lasers in Medical Science 3/2010

01-05-2010 | Original Article

Preliminary results on the use of a noninvasive instrument for the evaluation of the depth of pigmented skin lesions: numerical simulations and experimental measurements

Authors: Alida Mazzoli, Roberto Munaretto, Lorenzo Scalise

Published in: Lasers in Medical Science | Issue 3/2010

Login to get access

Abstract

The early detection of cutaneous pigmented lesions is an important aid to the clinician in recognizing malignant melanoma. In an attempt to correlate the depth of a pigmented skin lesion with its malignant potential, phantoms able to simulate the diffuse reflectance of some lesions of different thicknesses were manufactured and tested to validate a diagnostic instrument developed in-house. Such optical skin-tissue phantoms may be useful for accelerating and optimizing the diagnosis of suspicious lesions of the skin. In fact, benign melanocytic lesions are different in terms of their diffuse reflectance from melanoma. The diffuse reflectance of pigmented skin lesions depends on the amount and distribution of the absorbing/diffusing chromophores embedded in the skin layers. The basic phantom material is a PVA hydrogel in which appropriate amounts of optical scatter are added extraneously at the time of formation to achieve tunability of the optical properties. Liquid Indian ink is used to simulate melanin and all the other chromophores. Slabs were prepared to mimic lesions of different depths. The optical properties of the tissue phantoms were determined in the visible and near-infrared spectral ranges using a noninvasive instrument made from a purpose-modified digital camera. The measured reflectance was correlated with the depth of the lesion both in a Monte Carlo simulation environment and in a laboratory experiment.
Literature
1.
go back to reference Lualdi A, Colombo A, Mari A, Tomatis S, Marchesini R (2002) Development of simulated pigmented lesions in an optical skin-tissue phantom: experimental measurements in the visible and near infrared. J Laser Appl 14:122–127CrossRef Lualdi A, Colombo A, Mari A, Tomatis S, Marchesini R (2002) Development of simulated pigmented lesions in an optical skin-tissue phantom: experimental measurements in the visible and near infrared. J Laser Appl 14:122–127CrossRef
2.
go back to reference Bono A, Tomatis S, Batoli C, Tragni G, Radaelli G, Maurichi A, Marchesini R (1999) The ABCD system of melanoma detection. A spectrophotometric analysis of the asymmetry, border, color and dimension. Cancer 85(1):72–77CrossRefPubMed Bono A, Tomatis S, Batoli C, Tragni G, Radaelli G, Maurichi A, Marchesini R (1999) The ABCD system of melanoma detection. A spectrophotometric analysis of the asymmetry, border, color and dimension. Cancer 85(1):72–77CrossRefPubMed
3.
go back to reference Breslow A (1970) Thickness, cross-sectional areas and depth of invasion in the prognosis of cutaneous melanoma. Ann Surg 172:902–908CrossRefPubMed Breslow A (1970) Thickness, cross-sectional areas and depth of invasion in the prognosis of cutaneous melanoma. Ann Surg 172:902–908CrossRefPubMed
4.
go back to reference Morton DL, Davtyan DG, Wanek LA (1993) Multivariate analysis of the relationship between survival and the microstage of primary melanoma by Clark level and Breslow thickness. Cancer 71:3737–3743CrossRefPubMed Morton DL, Davtyan DG, Wanek LA (1993) Multivariate analysis of the relationship between survival and the microstage of primary melanoma by Clark level and Breslow thickness. Cancer 71:3737–3743CrossRefPubMed
5.
go back to reference Clark WH Jr, From L, Bernardino EA, Mihm MC (1969) The histogenesis and biologic behavior of primary human malignant melanomas of the skin. Cancer Res 29:705–726PubMed Clark WH Jr, From L, Bernardino EA, Mihm MC (1969) The histogenesis and biologic behavior of primary human malignant melanomas of the skin. Cancer Res 29:705–726PubMed
6.
go back to reference Terstappen K, Larko O, Wennberg AM (2007) Pigmented basal cell carcinoma – comparing the diagnostic methods of SIAscopy and dermoscopy. Acta Derm Venereol 87(3):238–242PubMed Terstappen K, Larko O, Wennberg AM (2007) Pigmented basal cell carcinoma – comparing the diagnostic methods of SIAscopy and dermoscopy. Acta Derm Venereol 87(3):238–242PubMed
7.
go back to reference van Staveren HJ, Moes CJM, van Marle J, Prahl SA, van Gemert MCJ (1991) Light scattering in intralipid-10% in the wavelength range of 400–1100 nm. Appl Opt 30:4507–4514CrossRef van Staveren HJ, Moes CJM, van Marle J, Prahl SA, van Gemert MCJ (1991) Light scattering in intralipid-10% in the wavelength range of 400–1100 nm. Appl Opt 30:4507–4514CrossRef
8.
go back to reference Flock ST, Jacques SL, Wilson BC, Star WM, Vangemert MJC (1992) Optical-properties of intralipid – a phantom medium for light-propagation studies. Lasers Surg Med 12(5):510–519CrossRefPubMed Flock ST, Jacques SL, Wilson BC, Star WM, Vangemert MJC (1992) Optical-properties of intralipid – a phantom medium for light-propagation studies. Lasers Surg Med 12(5):510–519CrossRefPubMed
9.
go back to reference Tuchin VV (2000) Tissue optics: light scattering methods and instruments for medical diagnosis. SPIE, Bellingham Tuchin VV (2000) Tissue optics: light scattering methods and instruments for medical diagnosis. SPIE, Bellingham
10.
go back to reference Kharine A, Manohar S, Seeton R, Kolkman RG, Bolt RA, Steenbergen W, de Mul FF (2003) Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography. Phys Med Biol 48:357–370CrossRefPubMed Kharine A, Manohar S, Seeton R, Kolkman RG, Bolt RA, Steenbergen W, de Mul FF (2003) Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography. Phys Med Biol 48:357–370CrossRefPubMed
11.
go back to reference Pogue BW, Patterson MS (2006) Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. J Biomed Opt 11(4):041102CrossRefPubMed Pogue BW, Patterson MS (2006) Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. J Biomed Opt 11(4):041102CrossRefPubMed
12.
go back to reference Mazzoli A, Scalise L, Munaretto R (2008) Development of optical tissue phantoms for the evaluation of the thickness of pigmented skin lesions by a conveniently purpose-modified digital camera: numerical simulations and experimental measures. In: Hierlemann A (ed) Proceedings of the VI IASTED International Conference on Biomedical Engineering (BIOMED 2008). ACTA, Calgary, pp 172–177 Mazzoli A, Scalise L, Munaretto R (2008) Development of optical tissue phantoms for the evaluation of the thickness of pigmented skin lesions by a conveniently purpose-modified digital camera: numerical simulations and experimental measures. In: Hierlemann A (ed) Proceedings of the VI IASTED International Conference on Biomedical Engineering (BIOMED 2008). ACTA, Calgary, pp 172–177
13.
go back to reference Pravdin AB, Chernova SP, Papazoglou TG, Tuchin VV (2002) Tissue phantoms. In: Tuchin VV (ed) Handbook of optical biomedical diagnostics. SPIE, pp 311–346 Pravdin AB, Chernova SP, Papazoglou TG, Tuchin VV (2002) Tissue phantoms. In: Tuchin VV (ed) Handbook of optical biomedical diagnostics. SPIE, pp 311–346
14.
go back to reference Delfino I, Esposito R, Piccirillo B, Gaeta GM, Lepore M (2008) Static and dynamic light scattering properties of Intralipid aqueous suspension for tissue phantom preparation and calibration. Proc SPIE 6870:68700PCrossRef Delfino I, Esposito R, Piccirillo B, Gaeta GM, Lepore M (2008) Static and dynamic light scattering properties of Intralipid aqueous suspension for tissue phantom preparation and calibration. Proc SPIE 6870:68700PCrossRef
15.
go back to reference Madsen S, Patterson M, Wilson BC (1992) The use of India ink as an optical absorber in tissue-simulating phantoms. Phys Med Biol 37:985–993CrossRefPubMed Madsen S, Patterson M, Wilson BC (1992) The use of India ink as an optical absorber in tissue-simulating phantoms. Phys Med Biol 37:985–993CrossRefPubMed
16.
go back to reference Manohar S, Kharine A, van Hespen JC, Steenbergen W, van Leeuwen TG (2004) Photoacoustic mammography laboratory prototype: studies on breast tissue phantoms. J Biomed Opt 9:1172–1181CrossRefPubMed Manohar S, Kharine A, van Hespen JC, Steenbergen W, van Leeuwen TG (2004) Photoacoustic mammography laboratory prototype: studies on breast tissue phantoms. J Biomed Opt 9:1172–1181CrossRefPubMed
17.
go back to reference Manohar S, Kharine A, van Hespen JCG, Steenbergen W, van Leeuwen TG (2005) The Twente Photoacoustic Mammoscope: system overview and performance. Phys Med Biol 50:2543–2557CrossRefPubMed Manohar S, Kharine A, van Hespen JCG, Steenbergen W, van Leeuwen TG (2005) The Twente Photoacoustic Mammoscope: system overview and performance. Phys Med Biol 50:2543–2557CrossRefPubMed
18.
19.
go back to reference Meglinsky IV, Matcher SJ (2002) Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. Physiol Meas 23:741–753CrossRef Meglinsky IV, Matcher SJ (2002) Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. Physiol Meas 23:741–753CrossRef
20.
go back to reference Chen R, Huang Z, Lui H, Hamzavi I, McLean DI, Xie S, Zeng H (2007) Monte Carlo simulation of cutaneous reflectance and fluorescence measurements – the effect of melanin contents and localization. J Photochem Photobiol B 86(3):219–226CrossRefPubMed Chen R, Huang Z, Lui H, Hamzavi I, McLean DI, Xie S, Zeng H (2007) Monte Carlo simulation of cutaneous reflectance and fluorescence measurements – the effect of melanin contents and localization. J Photochem Photobiol B 86(3):219–226CrossRefPubMed
21.
go back to reference Marchesini R, Brambilla M, Clemente C, Maniezzo M, Sichirollo AE, Testori A, Venturoli DR, Cascinelli N (1991) In vivo spectrophotometric evaluation of neoplastic and nonneoplastic skin pigmented lesions – I Reflectance measurements. Photochem Photobiol 53:77–84CrossRefPubMed Marchesini R, Brambilla M, Clemente C, Maniezzo M, Sichirollo AE, Testori A, Venturoli DR, Cascinelli N (1991) In vivo spectrophotometric evaluation of neoplastic and nonneoplastic skin pigmented lesions – I Reflectance measurements. Photochem Photobiol 53:77–84CrossRefPubMed
22.
go back to reference Zonios G, Dimou A, Bassukas I, Galaris D, Tsolakidis A, Kaxiras E (2008) Melanin absorption spectroscopy: new method for noninvasive skin investigation and melanoma detection. J Biomed Opt 13(1):0140176CrossRef Zonios G, Dimou A, Bassukas I, Galaris D, Tsolakidis A, Kaxiras E (2008) Melanin absorption spectroscopy: new method for noninvasive skin investigation and melanoma detection. J Biomed Opt 13(1):0140176CrossRef
23.
go back to reference Hasegawa Y, Yamada Y, Tamura M, Nomura Y (1991) Monte Carlo simulation of light transmission through living tissues. Appl Optics 30:4515–4520CrossRef Hasegawa Y, Yamada Y, Tamura M, Nomura Y (1991) Monte Carlo simulation of light transmission through living tissues. Appl Optics 30:4515–4520CrossRef
24.
go back to reference Simpson CR, Kohl M, Essenpreis M, Cope M (1998) Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys Med Biol 43:2465–2478CrossRefPubMed Simpson CR, Kohl M, Essenpreis M, Cope M (1998) Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. Phys Med Biol 43:2465–2478CrossRefPubMed
25.
go back to reference Kumar D, Chacko S, Singh M (1999) Monte Carlo Simulation of photon scattering in biological tissue models. Indian J Biochem Biophys 36:330–336PubMed Kumar D, Chacko S, Singh M (1999) Monte Carlo Simulation of photon scattering in biological tissue models. Indian J Biochem Biophys 36:330–336PubMed
26.
go back to reference Meglinski IV, Matcher SJ (2002) Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. Physiol Meas 23:741–753CrossRefPubMed Meglinski IV, Matcher SJ (2002) Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. Physiol Meas 23:741–753CrossRefPubMed
27.
go back to reference Canpolat M, Mourant JR (2000) Optical measurement of photosensitizer concentration using a probe with a small source-detector separation. Proceedings of SPIE Bios 2000 Photonics West Conference, San Jose, CA Canpolat M, Mourant JR (2000) Optical measurement of photosensitizer concentration using a probe with a small source-detector separation. Proceedings of SPIE Bios 2000 Photonics West Conference, San Jose, CA
Metadata
Title
Preliminary results on the use of a noninvasive instrument for the evaluation of the depth of pigmented skin lesions: numerical simulations and experimental measurements
Authors
Alida Mazzoli
Roberto Munaretto
Lorenzo Scalise
Publication date
01-05-2010
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 3/2010
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-009-0724-x

Other articles of this Issue 3/2010

Lasers in Medical Science 3/2010 Go to the issue